Marjan Bolbolian

Marjan Bolbolian


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2022 in Clinics and Practice
Verified
Journal Article
Open access
PDF file
MRMasoumeh Ramezani
Masoumeh Ramezani
MBMarjan Bolbolian
Marjan Bolbolian
MAMohaddeseh Aliakbari
Mohaddeseh Aliakbari
AAAhad Alizadeh
Ahad Alizadeh
MTMaryam Tofangchiha
Maryam Tofangchiha
GDGiuseppe D’amato
Giuseppe D’amato
This study aimed to compare the accuracy of three types of apex locators versus digital radiography for working length (WL) determination. This experimental study was conducted on 58 extracted maxillary premolars. The teeth were decoronated, the access cavity was prepared, and WL was determined using a #15 K-file to serve as reference. The WL was then measured by Woodpex V, Woodpex III, and Root ZX apex locators in the presence of 0.9% saline, and also on a photostimulable phosphor plate (PSP) digital radiograph taken by the parallel technique. The values were compared with the actual WL using the paired t-test (alpha = 0.05). Digital radiography, Root ZX, Woodpex V, and Woodpex III determined the WL within ±0.5 mm from the actual value in 84.48%, 100%, 89.66%, and 87.93% of the cases, respectively. Woodpex V (p = 0.039), Woodpex III (p = 0.001), and Root ZX (p = 0.001) significantly over-estimated the WL. The WL measured on digital radiographs was not significantly different from the actual WL (p = 0.213). The position of the apical foramen (central/lateral) had no significant effect on the accuracy of WL determination by different techniques (p >0.05). Within the limitations of this in vitro study, all the tested modalities showed acceptable accuracy for WL determination in maxillary premolars.

1 January 2018 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
MBMarjan Bolbolian
Marjan Bolbolian
SGS Golchin
S Golchin
SFS Faegh
S Faegh
Establishing the working length at the apical constriction is considered ideal for root canal therapy. Because of the limitations of radiography and complicacy of the apex of the root, electronic measurement of canal length has become valuable for endodontic treatment. This study was designed to evaluation of the accuracy of the Root zx electronic apex locator in the presence of NaOCl 2.5% and chlorhexidine 0.2%. Thirty extracted human premolars with complete root formation were enrolled. The actual length (AL) was assessed visually (under stereo microscope) and teeth mounted in the saline model. The electronic length (EL) measurements were recorded in the presence of NaOCl 2.5% and chlorhexidine 0.2% and the differences between the EL and AL were compared. By accepting the error of 0.5 and 1 mm, the accuracy of Root zx was 76.7% and 96.7% in the presence of chlorhexidine 0.2% and 90% and 100% in the presence of NaOCl 2.5%, respectively. No statistical differences was found between the measured groups (P=0.223). Our results confirmed that Root zx can accurately determine the apical constriction in presence of both NaOCl 2.5% and chlorhexidine 0.2%. Key words:Chlorhexidine, Sodium Hypochlorite, Root ZX.

31 December 2022 in Folia Medica
Verified
Journal Article
Open access
PDF file
MBMarjan Bolbolian
Marjan Bolbolian
AHAtefeh Hamzei
Atefeh Hamzei
NMNavid Mohammadi
Navid Mohammadi
MTMaryam Tofangchiha
Maryam Tofangchiha
Introduction: A sealer’s ability to effectively and stably penetrate the dentinal tubules is an essential factor for selecting an effective root canal obturation material. Evaluation of the sealers’ penetration into the dentinal tubules provides valuable data in the endodontic treatment outcome.Aim: To compare the dentin penetration of AH Plus, Endoseal MTA, and Syntex endodontic sealers in the presence and absence of the smear layer.Materials and methods: Thirty single-rooted teeth were selected in the present in vitro study and randomly assigned to three experimental groups (n=10). Half of the samples were prepared by removing the smear layer in each group, and the remaining samples were prepared without removing the smear layer. Root canal preparation was carried out with the Perfect Rotary system up to file T3. The root canals were obturated with gutta-percha and AH Plus, Endoseal MTA, or Syntex endodontic sealers. The samples were incubated at 100% relative humidity at 37°C for one week. Each root was sectioned at 2-, 5-, and 8-mm distances from the apex, and sealer penetration depth at each section was determined under a scanning electron microscope (SEM). ANOVA was used to compare penetration depths.Results: There were significant differences in sealer penetration between the samples with and without smear layer removal in each group. The maximum and minimum sealer penetration was at the coronal and apical sections, respectively. The maximum sealer pe-netration depths in descending order were observed with AH Plus, Syntex, and Endoseal MTA sealers (p<0.05).Conclusions: Elimination of smear layer increased three sealers’ dentin penetration depth, with the deepest penetration for the AH Plus sealer in the coronal section without the smear layer.

24 October 2018
Verified
Journal Article
Open access
PDF file
MTMaryam Tofangchiha
Maryam Tofangchiha
MBMarjan Bolbolian
Marjan Bolbolian
SRSahar Rahrovan
Sahar Rahrovan
MMMonirsadat Mirzadeh
Monirsadat Mirzadeh
NHNeda Hajihassani
Neda Hajihassani
Cone-beam computed tomography (CBCT) is one of the most important diagnostic tools in maxillofacial imaging. Nowadays different sealers are used in root canal therapy and some of them can create artifact in CBCT images. The aim of this study was to evaluate the effect of different sealers including AH-26, Diadent, and Anyseal in creation of artifact bands in the CBCT images based on voxel size. A total of 44 single rooted extracted teeth were selected. The canals were prepared by crown-down technique. All teeth were manually filed up to master apical file (MAF) size 45 and 1 mm shorter than the apical foramen. The teeth were divided into 4 equal groups. The canals were filled with gutta-percha and either of sealers AH-26, Diadent or Anyseal by lateral condensation technique. The control group were filled just with gutta-percha without any sealer. The CBCT images were taken in voxel sizes of 0.3 and 0.15. The Fisher exact and McNemar tests were used for statistical analysis. Although, the control group had the lowest ratio of presence to absence of artifact, the ratio of presence to absence of artifact in voxel size of 0.3 and 0.15 mm were significantly lower in Anyseal than AH-26 (P=0.031, P=0.020) and Diadent (P=0.001, P=0.002). No significant difference was detected between two voxel sizes (P>0.05). In this in vitro study, all evaluated sealers induced artifacts in the CBCT images. Anyseal sealer had the lowest artifact in both evaluated voxel sizes.

1 November 2020 in Scientific Journal of Kurdistan University of Medical Sciences
Verified
Journal Article
Open access
PDF file
MTMaryam Tofangchiha
Maryam Tofangchiha
MBMarjan Bolbolian
Marjan Bolbolian
AGAmin Ghasemi
Amin Ghasemi
NHNahid Hemati
Nahid Hemati