Xiaojuan Zhang

Mrs. Xiaojuan Zhang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
XZXiaojuan Zhang
Xiaojuan Zhang
BJBo Jing
Bo Jing
XJXiaoxuan Jiao
Xiaoxuan Jiao
RYRuixu Yao
Ruixu Yao
The increasing deployment of photovoltaic (PV) systems necessitates robust fault detection mechanisms to ensure operational reliability and safety. Conventional approaches, however, struggle in complex industrial environments characterized by high noise, data incompleteness, and class imbalance. This study proposes an innovative Advanced CNN-BiLSTM architecture integrating multi-scale feature extraction with hierarchical attention to enhance PV fault detection. The proposed framework employs four parallel CNN branches with kernel sizes of 3, 7, 15, and 31 to capture temporal patterns across various time scales. These features are then integrated by an adaptive feature fusion network that utilizes multi-head attention. A two-layer bidirectional LSTM with temporal attention mechanism processes the fused features for final classification. Comprehensive evaluation on the GPVS-Faults dataset using a progressive difficulty validation framework demonstrates exceptional performance improvements. Under extreme industrial conditions, the proposed method achieves 83.25% accuracy, representing a substantial 119.48% relative improvement over baseline CNN-BiLSTM (37.93%). Ablation studies reveal that the multi-scale CNN contributes 28.0% of the total performance improvement, while adaptive feature fusion accounts for 22.0%. Furthermore, the proposed method demonstrates superior robustness under severe noise (σ = 0.20), high levels of missing data (15%), and significant outlier contamination (8%). These characteristics make the architecture highly suitable for real-world industrial deployment and establish a new paradigm for temporal feature fusion in renewable energy fault detection.

8 August 2025 in Scientific Reports
Verified
Journal Article
Open access
XZXiaojuan Zhang
Xiaojuan Zhang
BJBo Jing
Bo Jing
YWYuan Wang
Yuan Wang
XMXiangzhen Meng
Xiangzhen Meng
JZJie Zhang
Jie Zhang
The ports of the bi-directional converter exhibit negative impedance characteristics when the energy storage unit of a DC microgrid is operating in charging mode. This can decrease the system’s stability margin, potentially leading to oscillation instability. To address this issue, we propose a feed-forward compensation control method based on impedance shaping. This involves designing a transfer function within the current feed-forward loop of the energy storage converter to ensure that the current reference value follows changes in the bus voltage. Selecting an appropriate time constant ensures that the port impedance of the energy storage unit exhibits a positive resistive characteristic close to the oscillation frequency while retaining a negative impedance characteristic in the low-frequency range. This ensures the stability of system operation. MATLAB/Simulink simulations and RT-LAB semi-physical platform testing have verified that the proposed control method effectively enhances the system’s stability margin, ensuring stable operation and minimal steady-state voltage deviation.