Brooks D. Lindsey

Prof. Brooks D. Lindsey

The Wallace H. Coulter Department of Biomedical Engineering, Atlanta, Georgia, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2014 in Sensors
Verified
Journal Article
Open access
PDF file
KMKarl Martin
Karl Martin
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JMJianguo Ma
Jianguo Ma
MLMike Lee
Mike Lee
SLSibo Li
Sibo Li
PDPaul Dayton
Paul Dayton
For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.

26 September 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JRJuan D. Rojas
Juan D. Rojas
KMK. Heath Martin
K. Heath Martin
SSSarah E. Shelton
Sarah E. Shelton
PDPaul A. Dayton
Paul A. Dayton
Recently, dual-frequency transducers have enabled high-spatial-resolution and high-contrast imaging of vasculature with minimal tissue artifacts by transmitting at a low frequency and receiving broadband superharmonic echoes scattered by microbubble contrast agents. In this work, we examine the imaging parameters for optimizing contrast-totissue ratio (CTR) for dual-frequency imaging and the relationship with spatial resolution. Confocal piston transducers are used in a water bath setup to measure the SNR, CTR, and axial resolution for ultrasound imaging of nonlinear scattering of microbubble contrast agents when transmitting at a lower frequency (1.5 to 8 MHz) and receiving at a higher frequency (7.5 to 25 MHz). Parameters varied include the frequency and peak negative pressure of transmitted waves, center frequency of the receiving transducer, microbubble concentration, and microbubble size. CTR is maximized at the lowest transmission frequencies but would be acceptable for imaging in the 1.5 to 3.5 MHz range. At these frequencies, CTR is optimized when a receiving transducer with a center frequency of 10 MHz is used, with the maximum CTR of 25.5 dB occurring when transmitting at 1.5 MHz with a peak negative pressure of 1600 kPa and receiving with a center frequency of 10 MHz. Axial resolution is influenced more heavily by the receiving center frequency, with a weak decrease in measured pulse lengths associated with increasing transmit frequency. A microbubble population containing predominately 4-μm-diameter bubbles yielded the greatest CTR, followed by 1- and then 2-μm bubbles. Varying concentration showed little effect over the tested parameters. CTR dependence on transmit frequency and peak pressure were confirmed through in vivo imaging in two rodents. These findings may lead to improved imaging of vascular remodeling in superficial or luminal cancers such as those of the breast, prostate, and colon.

1 February 2009 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
SSStephen W. Smith
Stephen W. Smith
NINikolas M. Ivancevich
Nikolas M. Ivancevich
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JWJohn Whitman
John Whitman
ELEdward Light
Edward Light
DLDaniel T. Laskowitz
Daniel T. Laskowitz

1 June 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JRJuan D. Rojas
Juan D. Rojas
PDPaul Dayton
Paul Dayton

8 December 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SSSarah E. Shelton
Sarah E. Shelton
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JTJames K. Tsuruta
James K. Tsuruta
FFF. Stuart Foster
F. Stuart Foster
PDPaul Dayton
Paul Dayton

20 June 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
ELEdward D. Light
Edward D. Light
HNHeather A. Nicoletto
Heather A. Nicoletto
EBEllen R. Bennett
Ellen R. Bennett
DLDaniel T. Laskowitz
Daniel T. Laskowitz
SSStephen W. Smith
Stephen W. Smith
Because stroke remains an important and time-sensitive health concern in developed nations, we present a system capable of fusing 3-D transcranial ultrasound volumes acquired from two sides of the head. This system uses custom sparse array transducers built on flexible multilayer circuits that can be positioned for simultaneous imaging through both temporal acoustic windows, allowing for potential registration of multiple real-time 3-D scans of cerebral vasculature. We examine hardware considerations for new matrix arrays-transducer design and interconnects-in this application. Specifically, it is proposed that SNR may be increased by reducing the length of probe cables. This claim is evaluated as part of the presented system through simulation, experimental data, and in vivo imaging. Ultimately, gains in SNR of 7 dB are realized by replacing a standard probe cable with a much shorter flex interconnect; higher gains may be possible using ribbon-based probe cables. In vivo images are presented, showing cerebral arteries with and without the use of microbubble contrast agent; they have been registered and fused using a simple algorithm which maximizes normalized cross-correlation.