Jianguo Ma

Mr. Jianguo Ma


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2014 in Sensors
Verified
Journal Article
Open access
PDF file
KMKarl Martin
Karl Martin
Brooks D. LindseyBrooks D. Lindsey
Brooks D. Lindsey
JMJianguo Ma
Jianguo Ma
MLMike Lee
Mike Lee
SLSibo Li
Sibo Li
PDPaul Dayton
Paul Dayton
For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.

21 September 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CFChunlong Fei
Chunlong Fei
JMJianguo Ma
Jianguo Ma
CCChi Tat Chiu
Chi Tat Chiu
JWJay A. Williams
Jay A. Williams
WFWayne Fong
Wayne Fong
Qifa ZhouQifa Zhou
Qifa Zhou
Matching the acoustic impedance of high-frequency (≥100 MHz) ultrasound transducers to an aqueous loading medium remains a challenge for fabricating high-frequency transducers. The traditional matching layer design has been problematic to establish high matching performance given requirements on both specific acoustic impedance and precise thickness. Based on both mass-spring scheme and microwave matching network analysis, we interfaced metal-polymer layers for the matching effects. Both methods hold promises for guiding the metal-polymer matching layer design. A 100 MHz LiNbO3 transducer was fabricated to validate the performance of the both matching layer designs. In the pulse-echo experiment, the transducer echo amplitude increased by 84.4% and its −6dB bandwidth increased from 30.2% to 58.3% comparing to the non-matched condition, demonstrating that the matching layer design method is effective for developing high-frequency ultrasonic transducers.

9 April 2015 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JMJianguo Ma
Jianguo Ma
KMK Heath Martin
K Heath Martin
YLYang Li
Yang Li
PDPaul A Dayton
Paul A Dayton
KSK Kirk Shung
K Kirk Shung
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1–3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μ m compared to 150 μ m pulse length). These comparisons provide guidelines for the design of intravascular acoustic angiography transducers.

23 August 2018 in JCI Insight
Verified
Journal Article
Open access
PDF file
Yichen DingYichen Ding
Yichen Ding
JMJianguo Ma
Jianguo Ma
ALAdam David Langenbacher
Adam David Langenbacher
KBKyung In Baek
Kyung In Baek
JLJu-hyun Lee
Ju-hyun Lee
THTzung Hsiai
Tzung Hsiai
The ability to image tissue morphogenesis in real-time and in 3-dimensions (3-D) remains an optical challenge. The advent of light-sheet fluorescence microscopy (LSFM) has advanced developmental biology and tissue regeneration research. In this review, we introduce a LSFM system in which the illumination lens reshapes a thin light-sheet to rapidly scan across a sample of interest while the detection lens orthogonally collects the imaging data. This multiscale strategy provides deep-tissue penetration, high-spatiotemporal resolution, and minimal photobleaching and phototoxicity, allowing in vivo visualization of a variety of tissues and processes, ranging from developing hearts in live zebrafish embryos to ex vivo interrogation of the microarchitecture of optically cleared neonatal hearts. Here, we highlight multiple applications of LSFM and discuss several studies that have allowed better characterization of developmental and pathological processes in multiple models and tissues. These findings demonstrate the capacity of multiscale light-sheet imaging to uncover cardiovascular developmental and regenerative phenomena.

16 March 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JMJianguo Ma
Jianguo Ma
MSMichael B. Steer
Michael B. Steer
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
Acoustic filters (AFs) are key components to control wave propagation in multi-frequency systems. We present a design which selectively achieves acoustic filtering with a stop band and passive amplification at the high- and low-frequencies, respectively. Measurement results from the prototypes closely match the design predictions. The AF suppresses the high frequency aliasing echo by 14.5 dB and amplifies the low frequency transmission by 8.0 dB, increasing an axial resolution from 416 to 86 μm in imaging. The AF design approach is proved to be effective in multi-frequency systems.

8 July 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JMJianguo Ma
Jianguo Ma
SGSijia Guo
Sijia Guo
DWDi Wu
Di Wu
XGXuecang Geng
Xuecang Geng
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
High-intensity focused ultrasound (HIFU) treatment efficiency is critical in maximizing the hyperthermia and reducing the surgery time. In this paper, a single-aperture, 1.5 MHz/3 MHz dual-frequency HIFU transducer was designed, fabricated, and characterized for tissue ablation enhancement. Double PZT-2 layers were configured in serial and dual-frequency ultrasound waves can be concurrently generated by exciting one of the PZT-2 layers. Impulse responses from the prototype showed that the wave amplitudes at 1.5 and 3 MHz were about the same, and both are more than 12 dB larger than those of higher orders of harmonics. Tissue ablation tests demonstrated that higher temperature rise can be achieved with dual-frequency ultrasound than with single-frequency ablation at the same acoustic power.