HAINING TANG

Prof. Dr. HAINING TANG


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2026 in Processes
Verified
Journal Article
Open access
PDF file
XFXingxing Fan
Xingxing Fan
MGManxiang Gao
Manxiang Gao
YWYong Wang
Yong Wang
HTHaining Tang
Haining Tang
FSFengyong SUN
Fengyong SUN
HTHAINING TANG
HAINING TANG
Images of wind turbine blades captured by drones often feature complex backgrounds, and small targets such as minor defects or images have low resolution, leading to reduced recognition rates. To address environments with complex feature backgrounds, this paper proposes the PPS-MSDeim model. Based on the lightweight end-to-end detection framework DEIM-N, it introduces three core innovations to tackle the challenge of detecting small, irregular defects on wind turbine blades against complex backgrounds. First, we design an inverted multi-scale deep separable convolutional module (MDSC). After compressing channels via a bottleneck layer, it concurrently processes 3 × 3, 5 × 5, and 7 × 7 inverted deep separable convolutions. By first fusing channel information and then extracting multi-receiver-field spatial features, this approach enhances the ability to characterize morphologically variable defects while reducing computational overhead. The MDSC is then embedded into the backbone network HGNetv2. Second, we construct a Multi-Scale Feature Aggregation and Diffusion Pyramid Network (MFADPN). Through a Multi-Scale Feature Aggregation Module (MSFAM), it directly fuses features from layers P2 to P5, achieving deep integration of high-level semantics and low-level details. Combining dilated convolutions with expansion ratios of 1, 3, and 5 captures multi-level context, and a Sobel edge branch is introduced to enhance defect contours; subsequently, a feature diffusion operation is performed to distribute the enhanced features back to each level, shortening information paths and preventing signal decay; simultaneously, a high-resolution detection head is added to P2 and the P5 head is removed to improve sensitivity for small object detection. Finally, we propose the PPSformer module to replace the original Transformer encoding layer. It uses patch embedding to convert images into sequences and introduces a multi-head probabilistic sparse self-attention mechanism that focuses only on key-value pairs during attention computation. This design efficiently captures irregularly varying feature information and globally detects data anomalies induced by external defects. This study uses real engineering data sets, and the results show that PPS-MSDeim, based on DEIM, increased mAP@0.5 by 6.7%, reaching 95.1%. mAP@0.5–0.95 increased by 12.0%, reaching 70.1%. This indicates that the proposed method has a significant advantage in detecting defects in wind turbine blades.

5 March 2026 in Electronics
Verified
Journal Article
Open access
PDF file
XFXingxing Fan
Xingxing Fan
MGManxiang Gao
Manxiang Gao
YWYong Wang
Yong Wang
HTHaining Tang
Haining Tang
FSFengyong SUN
Fengyong SUN
HTHAINING TANG
HAINING TANG
Real-world power transmission inspection faces acute data scarcity and severe class imbalance, as defective insulator instances are exceptionally rare compared to normal samples. To enable robust defect detection under such constraints, we present MS-LaT—a backbone networkthat fuses multi-granularity feature learning with latent context-aware fusion. The architecture processes visual inputs through a streamlined pipeline: an input stage employing AdaptTeLU-augmented inverted multi-scale separable-residual convolutions to discern subtle local anomalies; a contextual reasoning stage powered by a Latent Transformer encoder with Multi-Head Latent Attention (MLA) for holistic scene understanding; and an output stage utilizing AdaptTeLU-refined inverted multi-scale convolutions to produce precise diagnostic decisions. Domain-adaptive batch normalization (AdaBN) is embedded to minimize cross-domain feature divergence, substantially boosting generalization across diverse operational environments. Research utilising real-world engineering datasets demonstrates the proposed method’s robust insulator defect detection capability in complex environments.

19 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
TJTianbin Jiang
Tianbin Jiang
ZGZhongming Gong
Zhongming Gong
WCWenbo Cao
Wenbo Cao
HTHaining Tang
Haining Tang
HTHAINING TANG
HAINING TANG
High penetration of inverter-interfaced renewable generation reduces power system inertia and increases the demand for fast plant-level frequency support. This paper proposes a model predictive control (MPC)-based coordinated frequency support strategy for renewable power plants integrating wind power, photovoltaic (PV) generation, and hybrid energy storage systems (HESSs). An equivalent grid frequency response model is first established and combined with aggregated dynamic models of wind, PV, and heterogeneous HESS units to develop a unified control-oriented state-space formulation. In this framework, renewable reserve limits, storage power constraints, and state-of-charge (SoC) dynamics are explicitly incorporated to characterize the time-varying feasible support capability of the plant. On this basis, the coordinated frequency support problem is formulated as a constrained receding-horizon optimization problem, in which frequency deviation suppression, plant-level supplementary power coordination, and HESS energy-state management are considered simultaneously. Simulation studies under step-change and random load disturbances demonstrate the effectiveness of the proposed strategy. Under the representative step-change disturbance, the maximum frequency deviation is limited to approximately 4.5×10−4 p.u., and the frequency rapidly recovers to a steady operating region. Under random load disturbances, the frequency deviation remains bounded within approximately ±1.0×10−3 p.u. Moreover, the SoC values of all heterogeneous storage units remain within the prescribed range of 0.3–0.7 p.u. throughout the support process. These results demonstrate that the proposed strategy achieves effective transient frequency support while maintaining coordinated active power allocation and feasible HESS energy-state operation.

Verified
Journal Article
Open access
PDF file
HTHAINING TANG
HAINING TANG
FSFengyong SUN
Fengyong SUN
FYFan Yang
Fan Yang
This paper proposes a Boost + LLC converter-based power controller for ocean buoy tidal energy systems. To optimize output power across a wide input voltage range (40–120 V) and achieve effective power tracking control, we introduce two key innovations as follows: (1) a variable-mode inverter hybrid control strategy, combining smooth-mode switching with inverter control to enable wide gain range regulation. (2) An improved Grey Wolf Optimization (GWO) algorithm, enhanced by integrating a PSO-based elite wolf search strategy preventing local optima and maximizing power capture. Saber and Matlab simulations demonstrate that the proposed approach yields faster power tracking response and increases output power by 5–10% compared to traditional methods. The combined controller and improved GWO algorithm provide a stable and efficient solution for small-scale ocean energy systems, offering practical insights for power regulation in other marine energy sources like wave, wind, and solar.