YIMING PENG

Dr. YIMING PENG


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2026 in Buildings
Verified
Journal Article
Open access
PDF file
YPYIMING PENG
YIMING PENG
DHDaisi Huang
Daisi Huang
GZGuibin Zhang
Guibin Zhang
TWTukun WANG
Tukun WANG
HCHao Chen
Hao Chen
TSTianze Shen
Tianze Shen
Historic overseas-Chinese residences in hot–humid coastal regions face interconnected challenges involving surface deterioration, environmental performance, continued use, and long-term sustainability. Existing digital conservation studies often address these issues separately, resulting in fragmented information, weak spatial associations, and discontinuities across survey, diagnosis, intervention, and reinspection. This study develops a Revit/HBIM-based, Digital Twin-assisted multi-module information-integration and updating framework using Yingchuan Shijia, Jingzu Jiashu, Mingde Jiashu, and Chaoyang Xiyuan as complementary cases. Multi-source digital documentation, AI-assisted deterioration screening, building-performance simulation, adaptive-use assessment, and operational-carbon evaluation are integrated within a unified Revit/HBIM environment. The principal innovation lies in a unified parametric information architecture that organizes heterogeneous conservation evidence through stable Building–Space–Component–Surface–System identities, M0–M3 condition-localization logic, and persistent Scenario, Verification, Revision, and Predecessor relationships, enabling cross-module retrieval, evidence-to-decision linkage, and traceable updating. Previously established results are incorporated as module-level evidence rather than presented as new findings. The adopted YOLOv8 deterioration-screening study reported a Precision of 0.85, Recall of 0.72, mAP50 of 0.83, and mAP50–95 of 0.58, while previous Jingzu Jiashu simulations showed summer comfortable-hour ratios increasing from 7.29–7.78% to 32.00–42.45%. Chaoyang Xiyuan is introduced as a focal additional case extending the framework to adaptive reuse and sustainability assessment. Its earlier residential-use assessment reported 60.95 kgCO2e/(m2·a), compared with 56.14 kgCO2e/(m2·a) for the reference building; the later restaurant-inclusive scenario reported 295.81 versus 404.45 kgCO2e/(m2·a), with cooking-related emissions accounting for 78.9% of the design total. The proposed Digital Twin operates as an asynchronous, human-reviewed information-updating mechanism connecting physical assets, HBIM representations, professional evidence, conservation decisions, intervention, and reinspection. The framework provides a structured and traceable decision-support basis for long-term preventive conservation and sustainable activation.