Feng Liu

Dr. Feng Liu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FLFeng Liu
Feng Liu
PGPanpan Guo
Panpan Guo
HXHu Xunjian
Hu Xunjian
BLBaojian Li
Baojian Li
HHHaibo Hu
Haibo Hu
XGXiaonan Gong
Xiaonan Gong
The use of geosynthetic-encased stone columns has been proven to be an economical and effective method for soft soil foundation treatment. This method is widely used in civil engineering projects at home and abroad. When the geosynthetic-encased stone columns are applied to deep soft clays, they are in a floating state. The load-bearing deformation mechanism of geosynthetic-encased stone columns has changed. The interaction between the aggregates, geogrid, and soil is worth studying, especially at the bottom of the column. In this paper, the discrete element method is used to simulate a floating geosynthetic-encased stone column with a 280 mm encasement depth in deep soft clays. The load-bearing deformation characteristics and mesoscopic mechanism of the floating geosynthetic-encased stone column are studied. The results show that there are large vertical and radial stresses in the top region. Moreover, the porosity and sliding fraction of aggregates in this region increase with settlement, and the coordination number decreases with settlement. The vertical and radial stresses of the soil near the column body are not affected much by the column body. When the encasement depth exceeds 280 mm, the bearing capacity of the FGESC does not increase much. The encasement depth controls the failure mode of the floating geosynthetic-encased stone column. As the encasement depth increases, the failure mode of the floating geosynthetic-encased stone column gradually transitions from swelling deformation to penetration failure.

20 September 2021 in Geofluids
Verified
Journal Article
Open access
PDF file
FLFeng Liu
Feng Liu
PGPanpan Guo
Panpan Guo
HHHaibo Hu
Haibo Hu
CZChengwei Zhu
Chengwei Zhu
XGXiaonan Gong
Xiaonan Gong
This paper investigates the loading behavior and soil-structure interaction associated with a floating stone column under rigid foundation by using the discrete element method (DEM). The aggregates and soft soil are simulated by particles with different sizes. The rigid foundation is simulated by two loading plates at the same position with the same velocity. The stress distributions and microscopic interaction between the column and soft soil are investigated. The vertical stress of the column increases with settlement and decreases with the depth. The position of the column with large radial stress also has large deformation, which decreases from top to bottom. The vertical and radial stresses of the soft soil increase with settlement, and the radial stress shows high value in the upper part of soft soil. The stress concentration ratio is obtained by two loading plates, which decreases from 2.5 to 1.55 during loading. The interaction between column and soft soil shows that the column does not penetrate into the underlying stratum but drags the surrounding soil down.

25 July 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
ZPZHAO PING
ZHAO PING
YQYouqiang Qiu
Youqiang Qiu
FLFeng Liu
Feng Liu
ZWZhanqi Wang
Zhanqi Wang
PGPanpan Guo
Panpan Guo
Circular deep excavations, characterized by their symmetrical geometry, are commonly employed in constructing foundations for large-span suspension bridges and as launching shafts for shield tunneling. However, the mechanical behavior of such excavations under asymmetric surface surcharge remains inadequately understood due to a paucity of relevant investigations. This study addresses this knowledge gap by establishing a three-dimensional finite element model (3D-FEA) based on the anchor deep excavation project of a specific bridge. The model is utilized to investigate the influence of asymmetric surcharge on the forces and deformations within the supporting structure. The results show that both the internal force and displacement cloud diagrams of the support structure exhibit asymmetric characteristics. The distribution of displacement and internal forces has spatial effects, and the maximum values all occur in the areas where asymmetric loads are applied. The maximum values of the displacement, axial force, and shear force of underground continuous walls increase with the increase in the excavation depth. The total displacement curves all show the feature of a “bulging belly”. The maximum displacement is 13.3 mm. The axial force is mainly compression, with a maximum value of −9514 kN/m. The maximum positive and negative values of the shear force are 333 kN/m and −705 kN/m, respectively. The bending moment diagram of different monitoring points shows the characteristics of “bow knot”. The maximum values of the positive bending moment and negative bending moment are 1509.4 kN·m/m and −2394.3 kN·m/m, respectively. The axial force of the ring beam is mainly compression, with a maximum value of −5360 kN, which occurs in ring beams 3, 4, and 5. The displacement cloud diagram of the support structure under symmetrical loads shows symmetrical characteristics. Under different load conditions, the displacement curve of the diaphragm wall shows the characteristics of “bulge belly”. The forms of loads with displacements from largest to smallest at the same position are as follows: asymmetric loads, symmetrical loads, and no loads. These findings provide valuable insights for optimizing the structural design of similar deep excavation projects and contribute to promoting sustainable urban underground development.

1 May 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
QFQian Fan
Qian Fan
CCChupeng Chen
Chupeng Chen
FLFeng Liu
Feng Liu
HZHongrou Zheng
Hongrou Zheng
In order to study the attenuation law of skid resistance performance of asphalt pavement with thin overlay, the long-term tracking observation of the scrim force coefficient and the analysis of the attenuation change law were carried out on the asphalt pavement with AC-10 and OGFC-10 thin layer overlay. The volume index, water stability and high temperature stability were tested. The results show that, the attenuation law of the scrim force coefficient of OGFC-10 and AC-10 thin overlay asphalt pavement conforms to the Asymptotic model, showing a trend of rapid decrease first and then stability. It is recommended that “the value of stable scrim force coefficient” and “the time to reach the value of stable scrim force coefficient” should be used as the evaluation index of long-term skid resistance performance of asphalt pavement. The stability value is taken as the first evaluation index of asphalt pavement skid resistance performance, and the time to reach the stability value is the second evaluation index. Considering “the initial scrim force coefficient value”, “the stable scrim force coefficient value”, and “the time to reach the stable scrim force coefficient value”, the skid resistance performance of OGFC-10 thin layer overlay asphalt pavement is better than AC-10 thin layer overlay asphalt pavement.

28 August 2026 in Water
Verified
Journal Article
Open access
PDF file
FLFeng Liu
Feng Liu
JZJiancai Zhu
Jiancai Zhu
YWYan Wang
Yan Wang
HZHaiqi Zhang
Haiqi Zhang
Xinyu XieXinyu Xie
Xinyu Xie
PGPanpan Guo
Panpan Guo
Prefabricated vertical drains are critical for accelerating pore-water pressure dissipation and consolidating water-saturated soft soils in coastal and riverine environments. Straw drainage boards, composed of agricultural straw and polylactic acid (PLA), offer an alternative to traditional plastic drains, mitigating potential water pollution and microplastic accumulation in sensitive aquatic ecosystems. However, their slow natural biodegradability can impact long-term hydraulic performance and post-construction settlement. This study investigates the enzymatic degradation characteristics of straw–PLA drainage boards to optimize their hydraulic behavior and degradation in simulated water-saturated soft soils. We explored the effects of various bio-enzymes, specifically cellulase and alkaline protease, on the structural integrity and hydraulic properties of the drainage boards. Our results demonstrate that both enzymes significantly alter the water flow capacity of the boards, indicating accelerated degradation. Furthermore, a synergistic effect was observed when cellulase and alkaline protease were applied concurrently, leading to more pronounced degradation. The findings suggest that enzyme-enhanced degradation offers a promising strategy to optimize the hydraulic performance of drainage boards, facilitating more effective pore-water pressure dissipation and rapid soil consolidation in offshore and coastal engineering projects.

10 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
FLFeng Liu
Feng Liu
JZJiancai Zhu
Jiancai Zhu
HHHaibo Hu
Haibo Hu
SZShile Zhou
Shile Zhou
Xinyu XieXinyu Xie
Xinyu Xie
PGPanpan Guo
Panpan Guo
Geosynthetic-encased stone columns (GESCs) utilize geosynthetics to form a geosynthetic sleeve over a certain length of the stone column, thereby increasing lateral confinement and extending the engineering applications of conventional stone columns in ground improvement. In this paper, a series of laboratory model tests and discrete element numerical simulations were conducted to investigate the bearing behavior, load transfer mechanism, and deformation patterns of fully penetrating GESCs. The lateral confinement provided by the geogrid can increase the bearing capacity of fully penetrating GESCs, and the bearing capacity increases with increasing reinforcement depth. Compared with the ordinary stone column, the fully penetrating GESC with full-length encasement exhibits an approximately 1.5-fold increase in bearing capacity. The geogrid effectively restricts the movement of gravel particles; within the reinforced zone, the column deformation is relatively uniform, and bulging deformation occurs in the unreinforced section. Reinforced zone leads to a 10% decrease in the bulging ratio compared with the unreinforced section. The longer the encasement length, the more effectively the column transfers the upper load downward. When the reinforcement depth exceeds 75% of the column length, the improvement in bearing capacity of the fully penetrating GESC becomes less pronounced. Considering the encasement efficiency and engineering economy, it is recommended that the encasement length be 75% of the column length.