Background/Objectives: Telemedicine has emerged as a valuable tool for overcoming access barriers in healthcare, particularly in rehabilitation. However, the validity and reliability of remotely conducted physical capacity assessments remain unclear. This study evaluated the agreement and intra-rater reliability between in-person and tele-assessment administration of the one-minute sit-to-stand test (1 min-STST) in individuals with chronic respiratory diseases (CRDs). Methods: In this cross-sectional study, forty adults (55% female; mean age 59.8 ± 15.9 years) diagnosed with CRDs—including chronic obstructive pulmonary disease (52.5%), asthma (20%), and pulmonary fibrosis (20%)—completed the 1 min-STST in two conditions: in person and via tele-assessment. The primary outcome was the number of repetitions completed in each condition. Intra-rater reliability was analyzed using the intraclass correlation coefficient (ICC), and agreement between methods was evaluated with Bland–Altman analysis. Results: The mean number of repetitions was 24.4 ± 8.0 in person and 24.3 ± 8.1 via tele-assessment, with no significant difference (p = 0.78). Excellent reliability was observed (ICC = 0.978, p < 0.001), and Bland–Altman analysis showed good agreement with a mean difference of 0.08 ± 1.7 repetitions and limits of agreement from −3.26 to 3.41. No adverse events were reported. Conclusions: Tele-assessment of the 1 min-STST shows excellent agreement and reliability compared to in-person assessment in individuals with CRDs. These findings support tele-assessment as a valid and practical alternative for evaluating functional capacity remotely. Further research is needed to confirm its implementation in home-based or less-controlled settings.
Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a.nger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a speci.city of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the con.dence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.