Huixiang Wang

Huixiang Wang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
PTPuxun Tu
Puxun Tu
YGYao Gao
Yao Gao
ALAbel J Lungu
Abel J Lungu
DLDongyuan Li
Dongyuan Li
HWHuixiang Wang
Huixiang Wang
XCXiaojun Chen
Xiaojun Chen

8 April 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
PTPuxun Tu
Puxun Tu
HWHuixiang Wang
Huixiang Wang
LJLeo Joskowicz
Leo Joskowicz
XCXiaojun Chen
Xiaojun Chen

19 June 2024 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
BZBolun Zeng
Bolun Zeng
HWHuixiang Wang
Huixiang Wang
LJLeo Joskowicz
Leo Joskowicz
XCXiaojun Chen
Xiaojun Chen

13 April 2024 in BMC Surgery
Verified
Journal Article
Open access
PDF file
XTXingguang Tao
Xingguang Tao
FLFei Lyu
Fei Lyu
KSKapil Sugand
Kapil Sugand
KZKaihua Zhou
Kaihua Zhou
HWHuixiang Wang
Huixiang Wang
Background: Most 3D-printed guiding templates require dissection of soft tissues to match the corresponding surfaces of the guiding templates. This study sought to explore the accuracy and acceptability of the novel 3D printed individualized guiding templates based on cutaneous fiducial markers in minimally invasive screw placement for pelvic fractures. Methods: The printed template was tested on five high-fidelity biomimetic phantom models of the bony pelvis and its surrounding soft tissues as well as on two fresh frozen cadavers. Four cutaneous fiducial markers were transfixed on each phantom model prior to performing CT scans to reconstruct their 3D models. Personalized templates for guiding screw insertion were designed based on the positions of the fiducial markers and virtually planned target screw channels after scanning, followed by 3D printing of the guide. Phase 1 consisted of five expert surgeons inserting one anterograde supra-pubic screw and one sacroiliac screw percutaneously into each phantom model using the 3D-printed guide. The deviation of screw positions between the pre-operative planned and post-operative actual ones was measured after registering their 3D modelling. A Likert scale questionnaire was completed by the expert surgeons to assess their satisfaction and acceptability with the guiding template. Phase 2 consisted of repeating the same procedures on the fresh frozen cadavers in order to demonstrate face, content and concurrent validity. Results: In Phase 1, all ten screws were successfully implanted with the assistance of the guiding template. Postoperative CT scans confirmed that all screws were safely positioned within the bony pelvic channels without breaching the far cortex. The mean longitudinal deviation at the bony entry point and screw tip between the pre-operative planned and post-operative actual screw paths were 2.83 ± 0.60 mm and 3.12 ± 0.81 mm respectively, with a mean angular deviation of 1.25 ± 0.41°. Results from the Likert questionnaire indicated a high level of satisfaction for using the guiding template among surgeons. In Phase 2, results were similar to those in Phase 1. Conclusions: The 3D-printed guiding template based on cutaneous fiducial markers shows potential for assisting in the accurate insertion of percutaneous screws in the pelvis.

5 January 2024 in Research Square
Verified
Preprint
Open access
PDF file
XTXingguang Tao
Xingguang Tao
FLFei Lyu
Fei Lyu
KSKapil Sugand
Kapil Sugand
KZKaihua Zhou
Kaihua Zhou
HWHuixiang Wang
Huixiang Wang
Background Most 3D-printed guiding templates require dissection of soft tissues to match the corresponding surfaces of the guiding templates. This study sought to explore the accuracy and acceptability of the novel 3D printed individualized guiding templates based on cutaneous fiducial markers in minimally invasive screw placement for pelvic fractures. Methods The printed template was tested on five high-fidelity biomimetic phantom models of the bony pelvis and its surrounding soft tissues as well as on two fresh frozen cadavers. Four cutaneous fiducial markers were transfixed on each phantom model prior to performing CT scans to reconstruct their 3D models. Personalized templates for guiding screw insertion were designed based on the positions of the fiducial markers and virtually planned target screw channels after scanning, followed by 3D printing of the guide. Phase 1 consisted of five expert surgeons inserting one anterograde supra-pubic screw and one sacroiliac screw percutaneously into each phantom model using the 3D-printed guide. The deviation of screw positions between the pre-operative planned and post-operative actual ones was measured after registering their 3D modelling. A Likert scale questionnaire was completed by the expert surgeons to assess their satisfaction and acceptability with the guiding template. Phase 2 consisted of repeating the same procedures on the fresh frozen cadavers in order to demonstrate face, content and concurrent validity. Results In Phase 1, all ten screws were successfully implanted with the assistance of the guiding template. Postoperative CT scans confirmed that all screws were safely positioned within the bony pelvic channels without breaching the far cortex. The mean longitudinal deviation at the bony entry point and screw tip between the pre-operative planned and post-operative actual screw paths were 2.83 ± 0.60 mm and 3.12 ± 0.81 mm respectively, with a mean angular deviation of 1.25 ± 0.41°. Results from the Likert questionnaire indicated a high level of satisfaction for using the guiding template among surgeons. In Phase 2, results were similar to those in Phase 1. Conclusions The 3D-printed guiding template based on cutaneous fiducial markers shows potential for assisting in the accurate insertion of percutaneous screws in the pelvis.