Laurent Pitre

Dr. Laurent Pitre

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2014 in Metrologia
Verified
Journal Article
Closed access
MMM R Moldover
M R Moldover
RGR M Gavioso
R M Gavioso
JMJ B Mehl
J B Mehl
LPLaurent Pitre
Laurent Pitre
MPM de Podesta
M de Podesta
JZJ T Zhang
J T Zhang

13 January 2006 in Metrologia
Verified
Journal Article
Closed access
LPLaurent Pitre
Laurent Pitre
MMMichael R Moldover
Michael R Moldover
WTWeston L Tew
Weston L Tew

29 January 2011 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
JFJ. Fischer
J. Fischer
MPM. de Podesta
M. de Podesta
KHK. D. Hill
K. D. Hill
MMM. Moldover
M. Moldover
LPLaurent Pitre
Laurent Pitre
LWL. Wolber
L. Wolber

13 July 2011 in International Journal of Thermophysics
Verified
Journal Article
Open access
PDF file
LPLaurent Pitre
Laurent Pitre
FSFernando Sparasci
Fernando Sparasci
DTDaniel Truong
Daniel Truong
AGArnaud Guillou
Arnaud Guillou
LRLara Risegari
Lara Risegari
MHMarc E. Himbert
Marc E. Himbert
There is currently great interest in the international metrological community for new accurate determinations of the Boltzmann constant k B, with the prospect of a new definition of the unit of thermodynamic temperature, the kelvin. In fact, k B relates the unit of energy (the joule) to the unit of the thermodynamic temperature (the kelvin). One of the most accurate ways to access the value of the Boltzmann constant is from measurements of the velocity of the sound in a noble gas. In the method described here, the experimental determination has been performed in a closed quasi-spherical cavity. To improve the accuracy, all the parameters in the experiment (purity of the gas, static pressure, temperature, exact shape of the cavity monitored by EM microwaves, etc.) have to be carefully controlled. Correction terms have been computed using carefully validated theoretical models, and applied to the acoustic and microwave signals. We report on two sets of isothermal acoustic measurements yielding the value k B = 1.380 647 74(171) × 10−23 J · K−1 with a relative standard uncertainty of 1.24 parts in 106. This value lies 1.9 parts in 106 below the 2006 CODATA value (Mohr et al., Rev. Mod. Phys. 80, 633 (2008)), but, according to the uncertainties, remains consistent with it.

22 September 2004 in Review of Scientific Instruments
Verified
Journal Article
Closed access
EMEric F. May
Eric F. May
LPLaurent Pitre
Laurent Pitre
JMJames B. Mehl
James B. Mehl
MMMichael R. Moldover
Michael R. Moldover
JSJames W. Schmidt
James W. Schmidt
We evaluate a quasi-spherical, copper, microwave cavity resonator for accurately measuring the relative dielectric permittivity εr(p,T) of helium and argon. In a simple, crude approximation the cavity’s shape is a triaxial ellipsoid with axes of length a,1.001a and 1.005a , with a=5 cm . The unequal axes of the quasi-sphere separated each of the triply degenerate microwave resonance frequencies of a sphere (f11TM,f12TM,…,f11TE,f12TE,…) into three nonoverlapping, easily measured, frequencies. The frequency splittings are consistent with the cavity’s shape, as determined from dimensional measurements. We deduced εr(p,T) of helium and of argon at 289 K and up to 7 MPa from the resonance frequencies flnσ , the resonance half-widths glnσ , and the compressibility of copper. Simultaneous measurements of εr(p,T) with the quasi-spherical resonator and a cross capacitor agreed within 1×10−6 for helium, and for argon they differed by an average of only 1.4×10−6 . This small difference is within the stated uncertainty of the capacitance measurements. For helium, the resonator results for εr(p,T) were reproducible over intervals of days with a standard uncertainty of 0.2×10−6 , consistent with a temperature irreproducibility of 5 mK . We demonstrate that several properties of quasi-spherical cavity resonators make them well suited to εr(p,T) determinations. Ultimately, a quasi-spherical resonator may improve dielectric constant gas thermometry and realize a proposed pressure standard based on εr(p,T) .

1 January 2019 in Metrologia
Verified
Journal Article
Closed access
PRPatrick M C Rourke
Patrick M C Rourke
CGChristof Gaiser
Christof Gaiser
BGBo Gao
Bo Gao
DRDaniele Madonna Ripa
Daniele Madonna Ripa
MMMichael R Moldover
Michael R Moldover
RURobin J Underwood
Robin J Underwood
The principles and techniques of primary refractive-index gas thermometry (RIGT) are reviewed. Absolute primary RIGT using microwave measurements of helium-filled quasispherical resonators has been implemented at the temperatures of the triple points of neon, oxygen, argon and water, with relative standard uncertainties ranging from 9.1 × 10−6 to 3.5 × 10−5. Researchers are now also using argon-filled cylindrical microwave resonators for RIGT near ambient temperature, with relative standard uncertainties between 3.8 × 10−5 and 4.6 × 10−5, and conducting relative RIGT measurements on isobars at low temperatures. RIGT at optical frequencies is progressing, and has been used to perform a Boltzmann constant measurement at room temperature with a relative standard uncertainty of 1.2 × 10−5. Uncertainty budgets from implementations of absolute primary microwave RIGT, relative primary microwave RIGT and absolute primary optical RIGT are provided.