Nishant Pandya

Prof. Nishant Pandya

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
JHJuliette Heintz
Juliette Heintz
JBJean-Pierre Belaud
Jean-Pierre Belaud
NPNishant Pandya
Nishant Pandya
MSMoises Teles dos Santos
Moises Teles dos Santos
VGVincent GERBAUD
Vincent GERBAUD

29 July 2020
Verified
Book Chapter
Closed access
PDF file
USUrvashi Satwani
Urvashi Satwani
JSJaskanwar Singh
Jaskanwar Singh
NPNishant Pandya
Nishant Pandya


30 March 2026
Verified
Thesis
Closed access
NPNishant Pandya
Nishant Pandya
L’objectif de la thèse est d’effectuer l’analyse de sensibilité paramétrique du logiciel Phast de modélisation de la dispersion atmosphérique de gaz toxiques et/ou inflammables. La technique a consisté à coupler Phast et l’outil d’analyse de sensibilité SimLab, ce qui permet d’exécuter automatiquement un grand nombre de simulations en faisant varier l’ensemble des paramètres du modèle de façon simultanée. La méthode d’analyse de sensibilité globale choisie, E-FAST, est basée sur l’analyse de la variance des sorties du modèle pour le calcul des indices de sensibilité. Nous avons étudié des scénarios de rejet continus pour six produits différents (monoxyde d’azote, ammoniac, chlore, azote, n-hexane et fluorure d’hydrogène), sélectionnés pour couvrir une large gamme de caractéristiques physiques et de conditions de stockage. L’analyse du modèle de dispersion de Phast, Unified Dispersion Model, a été séparée en deux étapes : étape de « screening » avec pour but de comparer l’influence de l’ensemble des paramètres puis étude de l’influence globale des paramètres de modélisation, autres que les paramètres météo et du terme source, sur une plage large de valeurs. Pour chaque produit, nous avons décomposé les scénarios de base en sous-scénarios correspondant à des conditions de rejet différentes. Ce travail a notamment permis de classifier les paramètres du modèle selon leur degré d’influence sur la variabilité de différentes sorties et d’effectuer une analyse comparative par produit indiquant, pour des conditions de rejet données, quels paramètres sont les plus influents sur les sorties. Une étude complémentaire a consisté à effectuer une analyse de sensibilité locale de ces paramètres autour de leur valeur par défaut.

1 October 2025 in Surface Engineering
Verified
Journal Article
Closed access
JTJigneshkumar Thakkar
Jigneshkumar Thakkar
NPNishant Pandya
Nishant Pandya
Self-healing epoxy polysulfide coating has been developed using Allantoin Amino Silica (A 2 SiO 2 ) as an innovative filler, synthesized through innovative condensation polymerization and ultrasonication. Four dynamic formulations, featuring 3%, 5%, 10%, and 20% A 2 SiO 2 , were created, showcasing the potential of modern materials. The coatings (APY and A 2 SiO 2 ) were characterized with a robust array of techniques, including Particle Size Analysis, Thermogravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC), Pyrolysis Gas Chromatography-Mass Spectroscopy (Py GC-MS), Flow Injection Mass Spectrometry, Nuclear Magnetic Resonance Spectroscopy (1H NMR), and Fourier-transform Infrared Spectroscopy (FTIR). Remarkably, the 10% A 2 SiO 2 formulation emerged as the champion, improving abrasion resistance by 61.6% compared to the control, while maintaining tensile properties with minimal reduction in elongation and offering the highest wear resistance. This remarkable coating also displayed a contact angle greater than 90°, affirming its enhanced hydrophobicity. All formulations achieved an inspiring average self-healing rate of 86% at 50 °C after just 24 h.

1 August 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
BGBharat B Gulyani
Bharat B Gulyani
NPNishant Pandya
Nishant Pandya
The synthesis of heat exchanger networks (HEN) is an important field in process systems engineering, and considerable research efforts have been directed towards this goal in the past four decades. Many methodologies have been proposed to optimize the energy consumption in the process industries, with objectives of minimum utility consumption, minimum heat exchanger area, minimum number of heat exchange equipment, and minimum overall annualized cost. The strength of the Pinch Technology, the heuristics-based design and optimization method for HEN, lies in setting targets before the design. These targets, viz., area targets, units targets, shells targets, and total cost targets, are later used in arriving at optimal HEN. In the present paper, a new methodology has been presented which demonstrates the similarity of area targets and shells targets in an HEN employing multipass heat exchangers. Since area targets are inaccurate and fraught with uncertainties, it is pertinent to replace them with shells targets. Based on this, a design heuristics has been proposed for achieving optimal HEN.