Abdul Rahman Saleh

Prof. Abdul Rahman Saleh


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Journal of Endodontics
Verified
Journal Article
Closed access
ASAbdul Rahman Saleh
Abdul Rahman Saleh
PGPouyan Vakili Gilani
Pouyan Vakili Gilani
STSaeid Tavanafar
Saeid Tavanafar
ESEdgar Schäfer
Edgar Schäfer

1 November 2019 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
RAReem Alkhatri
Reem Alkhatri
ASAbdul Rahman Saleh
Abdul Rahman Saleh
Waad KhederWaad Kheder
Waad Kheder
Objective: The aim of this study was to measure the fracture resistance and failure modes of root-filled teeth restored with three different computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated post and core assemblies. Methods: Thirty extracted intact maxillary central incisors were used in the study, and the teeth were endodontically treated and sectioned to a root length of 16 mm. The samples were divided into three groups (n = 10) according to the mean of the dimensions at the cervical portion of the root. The posts and cores were fabricated with CAD/CAM technology using metal, zirconia, and polymer-infiltrated ceramic network (PICN) material. The posts were luted using resin cement, and then, metal crowns were fabricated, cemented, and then subjected to a compression to determine the fracture resistance force. Fracture of the post and core or fracture of the root above the level of the acrylic resin was considered as a favorable fracture, while nonfavorable fractures were those where the root fracture occurred below the level of the acrylic resin. Statistical analysis was carried out using SPSS software, and one-way analysis of variance was used to analyze root fracture resistance in Newton. The number of failure modes, post–core fractures and/or root fractures was calculated. The differences between study groups were revealed using the chi-square test. Results: The results of ANOVA revealed a nonsignificant difference in the resistance to fracture among the study groups (P = 0.114). The failure modes were nonfavorable for all metal and zirconia samples and seven PICN samples. However, three PICN samples exhibited a favorable represented by core fracture without root fracture. Conclusion: There was no significant difference between metal and zirconia samples in terms of nonfavorable fracture, while few PICN samples exhibited a favorable fracture. PICN material can be used in the fabrication of post and core assemblies using CAD/CAM.

31 March 2020 in The Saudi Dental Journal
Verified
Journal Article
Open access
ASAbdul Rahman Saleh
Abdul Rahman Saleh
MAMena Al-Ani
Mena Al-Ani
TATuqa Alrawi
Tuqa Alrawi
GAGhufran Al-Edressi
Ghufran Al-Edressi
This research aims to measure and compare the fracture resistance and modes of failure of the following three chemically varied computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic veneering materials: IPS e.max CAD, Vita Enamic, and Shofu HC. Twenty-seven sound human upper premolars were collected and stored in saline at room temperature until the experiment started and were assigned to three groups at random (n = 9). Putty indices were prepared to ensure a standardized butt joint preparation. An InEos X5 scanner was used to scan all the samples, and the resulting data were transferred to a CAD/CAM milling machine for veneer fabrication based on the materials used. Twenty-seven machined ceramic veneers were milled from three different ceramic materials. The cementation process was conducted for each material according to the manufacturer's instructions. To quantify the fracture resistance, all the samples underwent 2000 water cycles in a thermocycler and were then mounted in a universal testing machine at a 90° angle at the occlusal part of the veneer. The modes of failure were determined under a stereomicroscope and grouped into type I, ceramic fracture; type II, combined ceramic and tooth fracture; and type III, root fracture. Shofu HC had the highest mean (±standard deviation) fracture resistance (480.8 ± 92.8 N), followed by IPS e.max CAD (415.9 ± 147.2 N) and Vita Enamic (372.3 ± 123.9 N). However, the results of a one-way analysis of variance did not reveal statistically significant differences among the experimental groups (p = 0.194). The different groups exhibited different modes of failure, with ceramic fracture being the most common type of failure. All the materials tested in this study exhibited strong fracture resistance values, thereby indicating their use as veneering materials for the upper premolars.

11 October 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
NENesrine Aly Elsahn
Nesrine Aly Elsahn
Hatem Mostafa El-DamanhouryHatem Mostafa El-Damanhoury
Hatem Mostafa El-Damanhoury
ZSZainab Shirazi
Zainab Shirazi
ASAbdul Rahman Saleh
Abdul Rahman Saleh
Objectives This study was conducted to investigate the microhardness, surface roughness (Ra), and wear behavior of thin occlusal veneers (TOV) fabricated from different injectable composite materials and compare them to a Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) resin-based material. Materials and Methods A 1-mm occusal veneer preparation was done in a mandibular right second molar typodont tooth. The prepared model was duplicated to fabricate 32 replicas and divided into four groups (n = 8). Standard TOV were fabricated either indirectly from Cerasmart blocks, Cerasmart, GC (CS), or directly from Beautifil Injectable X, Shofu (BF), G-ænial Universal injectable, GC (GU), or SonicFill 2, Kerr (SF) using the injection molding technique. All the specimens were subjected to both thermomechanical cyclic loading (TMC) in a chewing simulator. Wear measurement was conducted by three-dimensional (3D) scanning of the veneered models before and after TMC, and the difference in the volume of the sample was recorded as the volumetric material loss due to wear. Ra before and after TMC and Vickers microhardness (VHN) of the tested materials were measured using standardized samples (n = 8). Representative samples from each group were investigated under a stereomicroscope and a scanning electron microscope. Statistical Analysis One-way analysis of variance (ANOVA) was applied to detect the effect of material on VHN and wear. Two-way ANOVA was utilized to examine the impact of material and TMC on Ra. Multiple comparisons between the groups were conducted using Tukey's post hoc test (α = 0.05). The Pearson's correlation coefficient was used to determine the relationship between hardness and wear and between roughness and wear (α = 0.05). Results CS exhibited the highest mean VHN (p ≤ 0.001), followed by GU and SF which were statistically similar (p = 0.883) but significantly higher than BF (p < 0.001). After TMC, GU revealed the lowest Ra and volumetric wear (VW), followed by CS, BF, and SF (p < 0.5). A highly significant correlation existed between Ra and VW (p = 0.001, R 2 = 0.9803). Conclusion The effect of TMC on the surface properties and wear resistance of the investigated TOV is material-dependent. GU injectable TOV are less influenced by TMC than CS milled TOV. In contrast, BF and SF demonstrated significant VW and Ra which might limit their clinical use as TOV. Article published online: 11 October 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

14 February 2023 in The Open Dentistry Journal
Verified
Journal Article
Open access
ZSZainab Shirazi
Zainab Shirazi
AAAnas Al-Jadaa
Anas Al-Jadaa
ASAbdul Rahman Saleh
Abdul Rahman Saleh
Background: The apical extent of instrument termination and final root-filling procedures have been found to be key prognostic factors in relation to the outcome of root canal treatment. The precise location of this termination point has always been a challenge in clinical endodontics. Until the introduction of contemporary electronic apex locators (EALs), conventional radiography was traditionally used to determine the working length. Since their inception more than 50 years ago, EALs have drawn a great deal of attention.Objective: The literature pertaining to these devices is saturated yet inexhaustive and controversial. While most reviews try to summarize this topic entirely, the scope of the subject makes this close to impossible. Most systematic reviews report a lack of high-quality evidence, making it impossible to reach a meaningful conclusion. This review of literature focuses on electronic apex location and its accuracy, specifically in relation to variables in the clinical setting that a practitioner might encounter while using this device.Methods: Electronic database searches were undertaken using a combination of key search words to find relevant studies about EALs.Results: The PubMed (MEDLINE) search engine was used to find studies published in the English language with no restrictions for time. Articles that were found to be most pertinent were chosen and included in the review.Conclusion: EALs are indispensable to the practice of endodontics; however, the adjunct use of radiographs remains a reasonable practice.

1 March 2019 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
STSaeid Tavanafar
Saeid Tavanafar
PGPouyan Vakili Gilani
Pouyan Vakili Gilani
ASAbdul Rahman Saleh
Abdul Rahman Saleh
ESEdgar Schäfer
Edgar Schäfer
Complex anatomy of roots requires endodontic rotary instruments that respect and follow that anatomy. The purpose of this study was to compare the shaping ability of three engine-driven nickel-titanium instruments in severely curved simulated canals. Forty-eight severely curved simulated canals in resin blocks were prepared to an apical size of 25 using the following systems (n = 16 per group): ProTaper Universal (PTU), ProTaper NEXT (PTN), and WaveOne Primary (WO) (all Dentsply Maillefer, Ballaigues, Switzerland). Composite images were made from the superimposition of pre- and post-instrumentation images. The amount of resin removed by each system was measured by using a digital template and image analysis software. Shaping ability of each system was compared using different parameters: total resin removal, centering ability, canal transportation in the apical, middle and coronal third of canal. Preparation times were also recorded. The data were statistically analyzed by using analysis of variance, paired t-test, and Tukey's post hoc test. Canals prepared with PTN were better centered in the apical part than those prepared with WO and PTU (p < 0.05). WO removed significantly more resin at the outer aspect of the maximum point of curvature. WO and PTU caused similar canal transportations at 7 points out of 11 measuring points. At measuring points 3, 4, and 5 WO caused more canal straightening than PTU. Instrumentation with PTU required more time than with the two other instruments (p <0.05). No preparation error or instrument separation occurred. In the apical part of the canals PTN obtained the best results with regard to canal transportation. All of the rotary instruments were safe in preparing severely curved canals and PTN showed better preparation of apical part of the canal.