Tingkui Wu

Prof. Dr. Tingkui Wu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
TWTingkui Wu
Tingkui Wu
YMYang Meng
Yang Meng
BWBeiyu Wang
Beiyu Wang
XRXin Rong
Xin Rong
YHYing Hong
Ying Hong
HLHao - Liu
Hao - Liu
Moderately increased motion at the intermediate segment (IS) after skip-level fusion may accelerate disc degeneration. However, limited biomechanical data are available that examine the effects on the IS following cervical disc arthroplasty (CDA). The purpose of this study is to investigate the biomechanical changes in the IS of the cervical spine after skip-level fusion or skip-level arthroplasty. A finite element model of a healthy cervical spine (C2-C7) was constructed. Two surgical models were developed: (1) skip-level fusion at C3/4 and C5/6 and (2) skip-level arthroplasty at C3/4 and C5/6. A 75-N follower load and 1.0-N·m moments were applied to the top of the C2 vertebra to produce flexion, extension, lateral bending and axial rotation in the intact model. The end-points in each direction corresponding to the intact model were applied to the surgical models under displacement-control protocols. The ranges of motion (ROMs) of the fusion model were markedly decreased at the operated levels, while the corresponding ROMs of the arthroplasty model were similar to those of the intact spine in all directions. In the fusion model, the ROMs of the IS (C4/5) were markedly increased in all directions. The ROMs in the arthroplasty model were similar to those in the intact spine, and the ROMs of untreated segments were evenly increased. In the fusion model, the intradiscal pressure and facet contact force at were C4/5 remarkably increased and unevenly distributed among the unfused segments. In the arthroplasty model, the IS did not experience additive stress. The IS does not experience additive ROM or stress in the intervertebral disc or facet joints after skip-level arthroplasty, which has fewer biomechanical effects on the IS than does skip-level fusion. This study provides a biomechanical rationale for arthroplasty in treating patients with skip-level cervical degenerative disc disease.

1 August 2020 in The Spine Journal
Verified
Journal Article
Closed access
TWTingkui Wu
Tingkui Wu
HLHao - Liu
Hao - Liu
BWBeiyu Wang
Beiyu Wang
JHJun-Bo He
Jun-Bo He
CDChen Ding
Chen Ding
YHYing Hong
Ying Hong

13 July 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
TWTingkui Wu
Tingkui Wu
HLHao - Liu
Hao - Liu
CDChen Ding
Chen Ding
XRXin Rong
Xin Rong
JHJun-Bo He
Jun-Bo He
BWBeiyu Wang
Beiyu Wang
Background: Cervical disc arthroplasty (CDA) has been demonstrated, in clinical trials, as an effective and safe treatment for patients diagnosed with radiculopathy and/or myelopathy. However, the current CDA indication criteria, based on the preoperative segmental range of motion (ROM), comprises a wide range of variability. Although the arthroplasty level preserved ROM averages 7°-9° after CDA, there are no clear guidelines on preoperatively limited or excessive ROM at the index level, which could be considered as suitable for CDA. Methods: This was a retrospective study of patients who underwent CDA between January 2008 and October 2018 using Prestige-LP discs in our hospital. They were divided into the small-ROM (≤5.5°) and the large-ROM (> 12.5°) groups according to preoperatively index-level ROM. Clinical outcomes, including the Japanese Orthopedics Association (JOA), Neck Disability Index (NDI), and Visual Analogue Scale (VAS) scores, were evaluated. Radiological parameters, including cervical lordosis, disc angle (DA), global and segmental ROM, disc height (DH), and complications were measured. Results: One hundred and twenty six patients, with a total of 132 arthroplasty segments were analyzed. There were 64 patients in the small-ROM and 62 in the large-ROM group. There were more patients diagnosed with cervical spondylosis in the small-ROM than in the large-ROM group (P = 0.046). Patients in both groups had significantly improved JOA, NDI, and VAS scores after surgery, but the intergroup difference was not significant. Patients in the small-ROM group had dramatic postoperative increase in cervical lordosis, global and segmental ROM (P < 0.001). However, there was a paradoxical postoperative decrease in global and segmental ROM in the large-ROM group postoperatively (P < 0.001). Patients in the small-ROM group had lower preoperative DH (P = 0.012), and a higher rate of postoperative heterotopic ossification (HO) (P = 0.037). Conclusion: Patients with preoperatively limited segmental ROM had severe HO, and achieved similar postoperative clinical outcomes as patients with preoperatively excessive segmental ROM. Patients with preoperatively limited segmental ROM showed a postoperative increase in segmental mobility, which decreased in patients with preoperatively excessive segmental ROM.

16 June 2023 in Trials
Verified
Journal Article
Open access
PDF file
JHJunbo He
Junbo He
QLQingyu Liu
Qingyu Liu
ZYZijiao Yang
Zijiao Yang
HLHao - Liu
Hao - Liu
TWTingkui Wu
Tingkui Wu
BWBeiyu Wang
Beiyu Wang
Introduction: Cervical hybrid surgery (HS) combines anterior cervical discectomy and fusion (ACDF) and cervical disc arthroplasty (CDA) to establish an individualized surgical plan for patients with multiple cervical disc degenerative diseases. In order to maintain the stability of the spine after HS, an external cervical collar is often used. However, there is still controversy regarding the importance of a cervical collar following surgery. This study aims to determine whether the cervical collar is effective and how long it should be worn after surgery. Methods: This is a randomized, single-center, prospective, parallel-controlled trial. Eligible participants will be selected according to the inclusion and exclusion criteria. The primary outcome is the neck disability index, which will be evaluated before surgery and at one week, 3 weeks, 6 weeks, 3 months, 6 months, and 12 months following surgery. The secondary outcomes consist of the Japanese Orthopedic Association Scores, MOS 36-item short-form health survey (SF-36), visual analog scale, Pittsburgh Sleep Quality Index (PSQI), Bazaz dysphagia scoring system, Falls Efficacy Scale, cervical collar satisfaction score, neck soft tissue assessment, and Braden Scale, as well as radiologic assessments for cervical lordosis, disc height of the operative levels, fusion rate, range of motion (ROM), and complications including anterior bone loss, prosthesis migration, and heterotopic ossification. The clinical and radiologic examinations were performed by investigators with no therapeutic relationship with the individual patient. All radiographs were examined by one independent radiologist. Ethics and dissemination: The results of this study will be published in peer-reviewed journals and presented at conferences. Upon completion of this trial, our findings could provide an appropriate cervical collar-wearing guideline for patients receiving HS. Trial registration: ChiCTR.org.cn ChiCTR2000033002. Registered on 2020–05-17.

16 August 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
HAHaimiti Abudouaini
Haimiti Abudouaini
TWTingkui Wu
Tingkui Wu
YMYang Meng
Yang Meng
BWBeiyu Wang
Beiyu Wang
HLHao Liu
Hao Liu
Anterior cervical surgery is widely accepted and time-tested surgical procedure for treating cervical radiculopathy and myelopathy. However, there is concern about the high adjacent segment degeneration rate and implant subsidence after the surgery using the traditional polyetheretherketone cage. Thus, we creatively designed a polyurethane cervical implant that can continuous load-sharing through elastic deformation and decrease postoperative stress concentration at adjacent segments. In this study, the design rationality and safety of this novel implant was evaluated based on several mechanical parameters including compression test, creeping test, push-out test and subsidence test. The results showed that the novel cervical implant remained intact under the compressive axial load of 8000 N and continues to maintained the elastic deformation phase. The minimum push-out load of the implant was 181.17 N, which was significantly higher than the maximum compressive shear load of 20 N experienced by a normal human cervical intervertebral disc. Besides, the creep recovery behaviour of the implant closely resembled what has been reported for natural intervertebral discs and clinically applied cervical devices in literature. Under the load of simulating daily activities of the cervical spine, the implant longitudinal displacement was only 0.54 mm. In conclusion, this study showed that the current design of the elastically deformable implant was reasonable and stable to fulfil the mechanical requirements of a cervical prosthesis under physiological loads. After a more comprehensive understanding of bone formation and stress distribution after implantation, this cervical implant is promising to be applied to certain patients in clinical practice.

8 October 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JHJunbo He
Junbo He
HLHao - Liu
Hao - Liu
TWTingkui Wu
Tingkui Wu
CDChen Ding
Chen Ding
KHKangkang Huang
Kangkang Huang
BWBeiyu Wang
Beiyu Wang
Background: Hybrid surgery (HS) has become an alternative procedure for the treatment of multilevel cervical degenerative disc disease with satisfactory outcomes. However, some adverse outcomes have recently emerged, such as heterotopic ossification (HO) and anterior bone loss (ABL). Furthermore, HO was found mostly located in the posterior and lateral of the cervical intervertebral disc space. The mechanism of anterior heterotopic ossification (AHO) formation may be different, and its relationship with ABL was uncertain. Methods: Radiographical and clinical outcomes of ninety-seven patients who had undergone contiguous two-level HS between December 2010 and December 2017 and with a minimum of 2-year follow-up were analyzed. Postoperative radiographs were evaluated and compared to the initial postoperative films to determine the incidence of ABL and AHO. Results: The overall incidence rate of ABL was 44.3% (43/97). It was identified in 70.6% of AHO cases (33.3% mild, 41.7% moderate, 25.0% severe) and 38.8% of non-AHO cases (38.7% mild, 45.2% moderate, 16.1% severe). A significant association between ABL and AHO occurrence was found (P = 0.016). There was no significant difference in prosthesis–endplate depth ratio or disc space angle change between the AHO group and the non-AHO group (P > 0.05). Compared with data preoperatively, clinical outcome scores significantly improved after surgery in both the AHO and non-AHO groups, with no significant differences between the two groups (P > 0.05). Conclusion: ABL was common in HS, and it related to AHO. The formation of AHO could be an integral part of postoperative bone remodeling, as well as ABL.