In this article, an optimal fault detection scheme is presented for a closed-loop control system, where an event-triggering mechanism is utilized for the transmission of output measurements, addressing the design of residual generation and evaluation, while considering the effects associated with unknown disturbances and faults in the system and event-triggered transmission errors on the generated residual. The triggering parameter-dependent residual generation is designed to achieve a best trade-off between robustness against unknown disturbances and sensitivity to faults, and the residual evaluation is designed to deliver a time-varying threshold that accounts for the effects of disturbances and event-triggered transmission errors on the generated residual. The results are general and simplify to those developed for optimal fault detection in time-triggered systems. In addition, a vehicle lateral dynamic system is adopted to demonstrate the applicability of the proposed optimal fault detection scheme as well as its advantages over an existing widely used event-triggered fault detection scheme.
Analytical model based fault diagnosis method is seldom adopted for heating, ventilating and air conditioning (HVAC) systems as it is rather difficult to establish and verify an explicit model for HVAC systems. On the other hand, a flexible graphically based software called TRNSYS has been widely accepted in the design and optimization of HVAC systems recently. It makes sense to use TRNSYS to establish and verify an analytical model for fault diagnosis of HVAC systems. In this paper, a TRNSYS model of a HVAC system in multi-zone buildings is firstly established on the basis of practical data. Then, a state-space model of HVAC system is given according to the thermal-mass balance and air flow balance equations, and the consistency between the TRNSYS model and the state-space model is demonstrated. Also, some typical faults in the HVAC system are considered and the consistency between the two models under the faulty cases is verified again. Further, the effects of the faults on energy consumption is analyzed. The results show that some faults such as pipe scaling can significantly increase energy consumption while having no obvious change in room temperature. Based on the established models, some promising and challenging research directions for fault diagnosis of HVAC systems are finally discussed.
Single traditional multivariate statistical monitoring methods, such as principal component analysis (PCA) and canonical variate analysis (CVA), are less effective in nonlinear dynamic processes. Monitoring approaches based on radial basis kernel function have been intensively applied. However, an infinite dimension nonlinear mapping is redundant and inefficient. To improve the efficiency of traditional methods and consider the nonlinearity and dynamics simultaneously, this paper proposes canonical variate nonlinear principal component analysis (CV-NPCA) based on explicit polynomial mapping and combined statistic for detecting and identifying faults in nonlinear dynamic processes. There are two main contributions of the proposed method. First, explicit second-order polynomial mapping is introduced to combine CVA with PCA to simultaneously decrease the adverse effects of nonlinearity and dynamics. Second, the $Q_{c}$ statistic combining residual vectors with residual components is proposed, and a two-dimensional (2D) contribution plot and the variable with the largest contribution based on the $Q_{c}$ statistic are given for fault identification in the simulation study. Compared with the results of PCA, CVA, kernel principal component analysis (KPCA), nonlinear dynamic principal component analysis (NDPCA) and kernel entropy component analysis (KECA), the proposed method not only has relatively higher fault detection rates and identification rates but also has lower false alarm rates in the numerical simulation process and the benchmark Tennessee Eastman process.
23 September 2025 in IEEE Transactions on Aerospace and Electronic Systems
This article focuses on achieving predefined-time (PT) bipartite consensus formation control in heterogeneous multi-agent system (MAS), which consist of underactuated USVs and UAVs with uncertain internal dynamics and external disturbances. Firstly, the heterogeneous USVs-UAVs system are subjected to a model transformation, converting it into fully actuated system. Then, a PT dynamic observer is developed to estimate both uncertain internal dynamics and external disturbances. Combining the virtual leader-follower model, a distributed predefined-time bipartite consensus sliding mode formation control (PTBCSMFC) protocol is developed for each heterogeneous USVs-UAVs system follower based on the designed PT observer, ensuring convergence at the predefined time. Finally, numerical simulations are performed under both fixed and time-varying formation scenarios to demonstrate the effectiveness of the proposed PTBCSMFC algorithm.
18 December 2014 in International Journal of Control, Automation, and Systems
In this article, a design framework is proposed and studied for an event-triggered active fault-tolerant control system. The considered control system is modelled with an injected actuator fault into the plant system, and it includes: (i) event detectors for the sensors and for the controller, which utilize event-triggered mechanisms to determine when information is to be sampled or updated, (ii) a fault diagnosis observer that resides at the controller to provide estimates of the states and the injected faults of the plant system, and (iii) a fault-tolerant controller that actively computes the control inputs while accounting for the estimates of the states and the injected faults of the plant system. The proposed design framework allows for the separation of the designs of the fault diagnosis observer and the fault-tolerant controller, to mitigate the coupling effect caused by the event-triggered mechanisms and avoid the computations of a higher order system. Also, a design procedure is presented to deliver the computation of the design variables to reduce the information transfer under injected faults, in both centralized and decentralized cases. Finally, a well-known unstable batch reactor benchmark system is adopted to demonstrate the applicability of the proposed design framework and its advantages over other approaches.