The present study is a theoretical calculation for the effects of high pressure on thermodynamic properties on GaN up to 40Gpa at room temperature. Volume compression ratio (V0/Vp), lattice constant (a) and elastic bulk modulus(B) have been established. Furthermore, lattice frequencies and disruptions function by analyzing phonon frequency spectrum (PFS) at (0 K). The entire calculations rely on using of two equation of state (EOS) "Birch-Murnaghan and modified Lennard-Jones" equation of state and with the integration of Grüneisen approximation theory. From the considered equations of state, formulation of bulk modulus was derived, that predicts a rising trend of bulk modulus. The large bulk modulus value of GaN has made a small fraction of change in volume (less than 15%) of the material even under an extreme pressure up to 45Gpa. It was also found that the results of phonon frequency spectrum obtained from Birch-Murnaghan equation of state in a better agreement with the experimental data than that of modified Lennard-Jones equation of state. Given that the Birch-Murnaghan equation of state developed according to Eulerian strain theory accounted as a universal equation of state. Moreover, good agreement between theoretically present calculations and experiment data of phonon frequency spectrum, reveals the validity of the equations of state used in the present study.
Passive Optical Network (PON) is a promising 5 G optical fiber network technology, that can enhance reliability data rate, and bandwidth saving. This simulation-based study investigates the feasibility of implementing a vertical cavity-surface emitting laser (VCSEL) optical source along with wavelength-division multiplexing (WDM) for designing a PON radio over fiber (RoF) system that can authorize multi-subscribers, users, to simultaneously use the same optical fiber for Front long-haul data transmission. Three scenarios are proposed: First, a VCSEL, and a Mach–Zehnder Modulator with a distinctive frequency are made accessible to every user in the PON system. Whereas, in the second scenario, a continuous wave (CW) laser is used to replace the VCSEL in the same PON. 16 users are multiplexed by a WDM and transmitted over a link length of 200 km. The system performance is, thus measured in terms of Q-factor, and it is revealed that the VCSEL-based system outperforms the system utilized CW laser to a distance of 150 km, with a maximum gain in the Q-factor of about 4.5. Both postulated systems are able to achieve a maximum transmission distance of 180 km with a minimum Q-factor of 6. Moreover, to minimize, the input current of around 1 mA and the system complexity, a third scenario is presented in which one VCSEL with 193.1 THz is shared among multiple users. The Q-factor performance is then simulated for up to 72 users, revealing that the minimum level of acceptable Q-factor has been maintained up to a link length of 180 km.