Human exploration of the lunar surface has large power requirements for both the lunar base and for rover exploration. NASA’s recent contract awards indicate a reliance on fission surface power. While nuclear options provide reliable power to lunar base locations, they have a limited reach that restricts exploration capacity. The Space Exploration Vehicle’s 125-mile range only allows coverage of 0.34% of the lunar surface. A constellation of space-based solar power (SBSP) satellites paired with pressurized rovers allows 24-h, full-surface coverage on excursions from the lunar base. A case study is conducted of the constellation design, system cost, operational lifetime, and power provided using SBSP. Results of the case study demonstrate that SBSP provides an additional 20 kW/h of emergency power and extends EVA range from 125 to 1000 km to cover 26 of the lunar geologic units, at an added lifecycle cost of less than 1% of the baseline mission cost. Addition of a SBSP constellation for rovers provides operational flexibility, safety, and robustness to enable multiple lunar exploration architectures beyond that enabled by surface power infrastructures, and should be further explored for lunar missions.
Measurable changes in electrophysiology have been documented in spaceflight, creating a pathway for disease genesis and progression in astronauts. These electrophysiology changes can be measured using potential difference (PD). A probe to measure PD was developed and is used clinically on Earth; this probe relies on fluid perfusion to establish an electrical connection to make PD measurements. The changes to fluid behavior in microgravity and partial gravity (including lunar and Martian gravity) drives the need to test this probe in a spaceflight environment. Here, we test the PD probe in a novel nasal cavity phantom in parabolic flight, simulating microgravity, lunar gravity, Martian gravity, and hypergravity conditions across 37 parabolas. The results are evaluated across gravity conditions using the Wilcoxon Rank Sum test. We record no statistically significant difference in probe PD measurements in 1 g, microgravity, lunar gravity, and hypergravity (approximately 1.8 g) conditions, reaching a NASA Technology Readiness Level 6. Martian gravity findings are inconclusive. Perfusion-based PD probes are therefore successfully demonstrated for use in spaceflight operation in microgravity, lunar gravity, and hypergravity environments; this establishes a foundation for moving towards the in-space testing of perfusion-based probes in astronauts.