Lucia Bizovska

Ms. Lucia Bizovska

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LBLucia Bizovska
Lucia Bizovska
ZSZdenek Svoboda
Zdenek Svoboda
MJMiroslav Janura
Miroslav Janura
MBMaria Cristina Bisi
Maria Cristina Bisi
NVNicolas VUILLERME
Nicolas VUILLERME
Computing the local dynamic stability using accelerometer data from inertial sensors has recently been proposed as a gait measure which may be able to identify elderly people at fall risk. However, the assumptions supporting this potential were concluded as most studies implement a retrospective fall history observation. The aim of this study was to evaluate the potential of local dynamic stability for fall risk prediction in a cohort of subjects over the age of 60 years using a prospective fall occurrence observation. A total of 131 elderly subjects voluntarily participated in this study. The baseline measurement included gait stability assessment using inertial sensors and clinical examination by Tinetti Balance Assessment Tool. After the baseline measurement, subjects were observed for a period of one year for fall occurrence. Our results demonstrated poor multiple falls predictive ability of trunk local dynamic stability (AUC = 0.673). The predictive ability improved when the local dynamic stability was combined with clinical measures, a combination of trunk medial-lateral local dynamic stability and Tinetti total score being the best predictor (AUC = 0.755). Together, the present findings suggest that the medial-lateral local dynamic stability during gait combined with a clinical score is a potential fall risk assessment measure in the elderly population.

27 February 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZSZdenek Svoboda
Zdenek Svoboda
LBLucia Bizovska
Lucia Bizovska
MJMiroslav Janura
Miroslav Janura
EKEliska Kubonova
Eliska Kubonova
KJKaterina Janurova
Katerina Janurova
NVNicolas VUILLERME
Nicolas VUILLERME
Considering that most of the falls in elderly population arise during walking, tests derived from walking performance would be desirable for comprehensive fall risk assessment. The analysis of spatial temporal parameters and the center of pressure displacement, which represents the interaction between the human body and the ground, would be beneficial. The aim of this study was to compare spatial temporal gait parameters and their variability and the variability of the center of pressure displacement between elderly fallers and nonfallers during gait at self-selected, defined and fast speeds. A prospective study design was used. At the baseline, measurements of ground reaction force during gait at self-selected, defined and fast walking speeds by two force plates were performed. In addition, the Tinetti balance assessment tool, the Falls Efficacy Scale-International and the Activities-Specific Balance Confidence Scale were used. Mean and coefficient of variation of spatial temporal gait parameters and standard deviations of center of pressure displacement during loading response, midstance, terminal stance and preswing phases were calculated. Comparison of the fallers and nonfallers exhibited no significant difference in clinical tool, scales or spatial temporal parameters. Compared to nonfallers’ increased variability of walking speed at self-selected and defined speed, step width at fast walking speed and center of pressure displacement during preswing phase in medial-lateral directions at defined walking speed was found in fallers. However, application of the Holm-Bonferroni procedure for multiple comparisons exhibited no significant effect of group in any of the gait parameters. In general, our study did not observe an effect of group (fallers vs. nonfallers) on variability of spatial temporal parameters and center of pressure movement during gait. However, walking speed, step width as well as standard deviation of COP displacement in the medial-lateral direction during preswing exhibited a certain potential for distinguishing between elderly fallers and nonfallers.

14 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DNDenisa Nohelova
Denisa Nohelova
LBLucia Bizovska
Lucia Bizovska
NVNicolas VUILLERME
Nicolas VUILLERME
ZSZdenek Svoboda
Zdenek Svoboda
Nowadays, gait assessment in the real life environment is gaining more attention. Therefore, it is desirable to know how some factors, such as surfaces (natural, artificial) or dual-tasking, influence real life gait pattern. The aim of this study was to assess gait variability and gait complexity during single and dual-task walking on different surfaces in an outdoor environment. Twenty-nine healthy young adults aged 23.31 ± 2.26 years (18 females, 11 males) walked at their preferred walking speed on three different surfaces (asphalt, cobbles, grass) in single-task and in two dual-task conditions (manual task—carrying a cup filled with water, cognitive task—subtracting the number 7). A triaxial inertial sensor attached to the lower trunk was used to record trunk acceleration during gait. From 15 strides, sample entropy (SampEn) as an indicator of gait complexity and root mean square (RMS) as an indicator of gait variability were computed. The findings demonstrate that in an outdoor environment, the surfaces significantly impacted only gait variability, not complexity, and that the tasks affected both gait variability and complexity in young healthy adults.

1 July 2014 in Gait & Posture
Verified
Journal Article
Closed access
LBLucia Bizovska
Lucia Bizovska
ZSZdenek Svoboda
Zdenek Svoboda
PKPatrik Kutilek
Patrik Kutilek
MJMiroslav Janura
Miroslav Janura
Aleš GábaAleš Gába
Aleš Gába
ZKZuzana Kovacikova
Zuzana Kovacikova

4 June 2018 in Medicina
Verified
Journal Article
Open access
PDF file
ZGZuzana Gonosova
Zuzana Gonosova
PLPetr Linduska
Petr Linduska
LBLucia Bizovska
Lucia Bizovska
ZSZdenek Svoboda
Zdenek Svoboda
For quantifying muscle strength in clinical and research practice, establishing the reliability of measurements, specifically to the procedures used, is essential for credible findings. The objective was to establish the reliability of isokinetic measurement of ankle plantar and dorsal flexors (PF/DF) and invertors and evertors (INV/EV) on an IsoMed 2000 dynamometer. Twenty healthy subjects (10 males, 10 females, mean age: 23.1 ± 3.1 years) completed an isokinetic measurement session. The intraclass correlation coefficient (ICC) and standard error of measurement were assessed for peak torque and work of ankle PF/DF (concentric and eccentric) and INV/EV (concentric) for the preferred and nonpreferred limb. Standardized isokinetic measurements of reciprocal PF/DF and INV/EV muscle actions were associated with ICC ranging from 0.77 to 0.98 for the majority of observed parameters. The exception was work in the eccentric mode in the ankle DF and peak torque in the concentric mode in the ankle INV on the preferred limb, where ICC ranged from 0.64 to 0.71. The IsoMed 2000 isokinetic dynamometer can be reliably employed in future studies for reciprocal ankle PF/DF and INV/EV assessment in healthy adult subjects after implementation of a familiarization session.

1 February 2017 in Gait & Posture
Verified
Journal Article
Closed access
LBLucia Bizovska
Lucia Bizovska
ZSZdenek Svoboda
Zdenek Svoboda
NVNicolas VUILLERME
Nicolas VUILLERME
MJMiroslav Janura
Miroslav Janura