19 November 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BFBehnam Feizifar
Behnam Feizifar
OUOmer Usta
Omer Usta
This paper introduces a condition monitoring (CM) algorithm based on the circuit breaker (CB) arcing power and its related energy to estimate the electrical wear of arcing contacts. There is an electric arc occurring between the CB arcing contacts mainly during opening operations. Instantaneous voltage across the terminals of CB and instantaneous current going through CB are measured to calculate the arcing power and its related energy which only exist under arcing events. Therefore, the power-based algorithm does not require time synchronization to power system frequency for measuring the CB arcing powers. The cumulative arcing energy of CB is a good indication of the degradation level of arcing contacts and it is used to estimate the CB contact wear. Unlike the current-based CM method, the proposed power-based algorithm detects arc restrikes that produce more arcing energies and cause greater contact wear. Thus, it allocates higher amount of contact wear for interruptions with arc restrikes that makes it a more reliable and accurate technique. The outcomes of computer simulation and real-time test studies demonstrate that the power-based method can estimate the electrical wear of arcing contacts accurately and thus provides accurate inspection or maintenance times of CB's arcing contacts.

1 November 2018 in Electric Power Systems Research
Verified
Journal Article
Closed access
BFBehnam Feizifar
Behnam Feizifar
OUOmer Usta
Omer Usta

1 August 2024 in IEEE Access
Verified
Journal Article
Open access
AAAbdulvehhab Ağin
Abdulvehhab Ağin
ADAyşen Demirören
Ayşen Demirören
OUOmer Usta
Omer Usta
This research addresses a significant gap in power system protection methodologies by developing a dedicated simulation environment that supports the communication of protection relays via the IEC 61850 protocol. Current studies have focused on hardware-in-the-loop approaches, but there is a lack of research in the software-in-the-loop domain. This limitation means that manufacturer-independent simulations cannot be performed, restricting testing to the capabilities provided by the manufacturer. By introducing a relay capable of communicating within a Simulink-modeled power system through socket programming, this study harnesses the capabilities of the IEC 61850 GOOSE protocol and sampled values. This work aims to eliminate the manufacturer dependencies present in hardware-in-the-loop approaches, thereby enabling the independent development of new protection and control strategies in an academic context. Furthermore, by facilitating advanced communication strategies through a detailed simulation framework, this research contributes to the broader field of electrical engineering by offering a robust tool for developing, testing, and validating new relay communication techniques and protection schemes. This approach not only fills a critical gap in simulation capabilities but also paves the way for future advancements in power system protection and management regarding the IEC 61850 protocol.

15 May 2019 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Open access
BFBehnam Feizifar
Behnam Feizifar
OUOmer Usta
Omer Usta

5 July 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BFBehnam Feizifar
Behnam Feizifar
ZMZdenek Muller
Zdenek Muller
OUOmer Usta
Omer Usta
This paper introduces a new algorithm for the early detection of abnormal arcing conditions of circuit breakers (CBs). Any interruption with a higher arcing time compared to maximum permissible arcing time (MPAT) of CB is defined as a CB failure to clear mode. Measuring CB arcing time is not easy because there is no control on the mechanical opening and closing instants of CB contacts. Nevertheless, there is a correlation between the spectral energy densities of CB arcing voltages and arcing times of CB. This correlation is used by calculating the spectral energy densities of the instantaneous system voltage and the instantaneous CB voltage across its terminals utilizing discrete Fourier transform (DFT) for two periods of the system frequency. The difference between the spectral energy densities at the fundamental frequency is defined as a criterion for identifying a failure to clear mode. Whenever this criterion exceeds a predefined trip level, it indicates the occurrence of a failure to clear mode. In this situation, a trip signal is initiated for adjacent CBs to isolate the faulted CB and the fault. The results obtained from computer simulations and measurements show that the algorithm discriminates between normal and abnormal arcing conditions of CB.

7 February 2019 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
BFBehnam Feizifar
Behnam Feizifar
OUOmer Usta
Omer Usta