Excited states of at high spins are studied using the reaction (,) at -MeV beam energy. The earlier known level scheme is extended up to -MeV excitation energy and () spin with the addition of several transitions. We have performed polarization asymmetry measurements for some of the strong transitions by using a Clover detector to assign the parity. A comparison of experimental data with the results of tilted axis cranking calculations based on various configurations indicates the coexistence of multiple minima in the triaxial deformation (), whereas axial symmetric deformation () remains constant around .
1 June 1993 in International Journal of Modern Physics E
The Variable Moment of Inertia (VMI) model is proposed for the assignment of band head spin of super deformed (SD) rotational bands, which in turn is helpful in the spin prediction of SD bands. The moment of inertia and stiffness parameter (C), were calculated by fitting the proposed transition energies. The calculated transition energies are highly dependent on the prescribed spins. The calculated and observed transition energies agree well when an accurate band head spin (I0) is assigned. The results are in good agreement with other theoretical results reported in literature. In this paper, we have reported the band head spin value 16 rotational band of super deformed Tl isotopes.
20 February 2019 in The European Physical Journal Plus
Reduction of radiation dose from medical investigations still remains an important strategy. The combined effect of the reduced injected activity of 18F – FDG, low tube voltage & iodine concentration with iterative reconstruction on image quality, radiation dose, and DNA damage in patients undergoing PET/CT examination were examined. The study includes 16 patients who underwent PET/CT investigation twice using two different protocols; standard & new. A new protocol was followed during follow-up after 4–6 months. All acquisition and reconstruction parameters were the same in both protocols, except administered activity, iodine concentration and CT tube voltage which was reduced. Image quality was assessed using various parameters. Effective dose from PET/CT was assessed using CTDIvol and ICRP coefficients. DNA damage analysis was performed using comet and γ-H2AX assay. No significant difference was noted in quality parameters between two protocols (p > 0.05) except CT noise level (p < 0.05). Mean iodine dose, total radiation dose, mean foci and TM in the new protocol were found significantly lower than standard PET/CT (p < 0.05). There were 26.68% reduction in radiation dose, 10% reduction in contrast load, 20.31% reduction in the number of foci and 17.67% reduction in TM was noted with optimized protocol.