Assessing femoral neck shortening (FNS) and varus collapse after internal fixation of femoral neck fractures using computerized navigation (CN). Retrospective cohort study. Academic Level I trauma center. Forty-one patients who had healed femoral neck fractures treated with CN between the years 2003 and 2008. Average age was 65 years (range, 14-91 years). Thirty-six patients had nondisplaced fractures and five had displaced fractures. Screws were placed using CN in an inverted triangle formation Follow-up films were digitized into a PACS system, calibrated, and analyzed using CAD software. The following parameters were recorded: abductor lever arm shortening (termed x), corresponding vertical femur shortening (termed y), and the resultant femoral neck shortening vector (z). Fifteen patients were available for clinical outcome measures by the means of SF-12 survey Significant FNS of the x component (greater than 5 mm) occurred in 30 of 42 (71%) patients with severe shortening (greater than 10 mm) in 25% of the patients. Significant y shortening occurred in 43% of the patients and severe shortening in 17%. Overall (z) femoral neck shortening occurred in 56% of the patients with severe shortening in 22% of patients. Varus collapse (greater than 5°) did not occur in any patient. Screw pullout (greater than 5 mm) occurred in 17 (41%) patients. Seven patients required late (greater than 6 months) arthroplasty postoperatively. FNS did not significantly correlate with fracture type, quality of reduction, age, or neck shaft angle. SF-12 results were negatively correlated with overall FNS. Our results show a high degree of FNS associated with the use of CN for fixation of femoral neck fractures, similar to recently published series using nonnavigated implants. However, no varus collapse occurred in our series. Our preliminary clinical data show a trend toward an adverse effect of FNS on quality-of-life measures.
Traditionally, both high- and low-energy tibial plateau fractures are classified on the basis of the anteroposterior (AP) plain radiograph. Several fracture types exist that are not included in currently used classification schemes, including posteromedial shear and coronal plane fractures. These fracture types can appear as isolated fracture lines or as a part of a bicondylar plateau fracture. The purpose of this study is to describe a posteromedial supine surgical approach and antiglide plating of the posteromedial fragment, either as a single approach for a unicondylar posteromedial fracture or in combination with a second lateral approach for bicondylar fractures. We have used this technique in 27 patients that had posteromedial shear fractures on preoperative computed tomography (CT) scans, in the setting of a Level I trauma center. Ten were isolated medial plateau fractures, and 17 had bicondylar fractures. Radiographic analysis was done for all patients, and clinical outcomes were available in 19 out of 27 patients through phone interviews and chart reviews. Mean follow-up was 3.5 years (range 1-12 years). Seventy-five percent of patients had anatomic or good reductions. The average Oxford knee score was 19.9 +/- 5.4 (12-29). Average range of motion was 0 to 120 (0-90 to 0-130). The articular malreduction (>5-mm gap or step-off) rate was 4%, and there were no wound complications. Posteromedial shear fractures of the tibial plateau are not uncommon. This pattern is assessable using the preoperative CT scan. A supine posteromedial approach with antiglide plating provides a good clinical solution for these complex injuries.
New implant designs like the Proximal Femoral Nail Antirotation (PFNA) were developed to reduce failure rates in unstable pertrochanteric fractures in the elderly. Standardized implant augmentation with up to 6 mL of polymethylmethacrylate (PMMA) cement has been introduced to enhance implant anchorage by increasing the implant-bone interface in osteoporotic bone conditions. Biomechanically, loads to failure were significantly higher with augmentation. The primary objective of this study was to compare the mobility of patients with closed unstable trochanteric fractures treated by PFNA either with or without cement augmentation. A prospective multicentre, randomized, patient-blinded trial was conducted with ambulatory patients aged 75 or older who sustained a closed, unstable trochanteric fracture. Surgical fixation had to be performed within 72 h after admission. Outcomes were evaluated at baseline, during surgery, 3 to 14 days after surgery, 3 months, 6 months, and 12 months after surgery. To evaluate the primary objective, patients' walking speed was assessed by the Timed Up and Go (TUG) test. Secondary objectives included the analysis of implant migration assessed on radiographs, quality of life measured by the Barthel Index, mobility measured by the Parker Mobility Score, and complications. Of 253 randomized patients, 223 patients were eligible: 105 patients were allocated to the PFNA Augmentation group and 118 to PFNA group. At 3 to 14 days after surgery, there was no statistical significant difference in mean walking speed between the treatment groups. For the secondary objectives, also no statistical significant differences were found. However, no patient in the PFNA Augmentation group had a reoperation due to mechanical failure or symptomatic implant migration compared to 6 patients in the PFNA group. Augmentation of the PFNA blade did not improve patients' walking ability compared to the use of a non-augmented PFNA but might have the potential to prevent reoperations by strengthening the osteosynthesis construct.
Objective: To determine the effectiveness of closed, intramedullary exchange nailing with reamed insertion for the treatment of femoral shaft nonunions previously treated with an intramedullary nail. Design: Retrospective cohort study. Setting: Academic level I trauma center. Patients: Forty-two patients whose femoral shaft fracture was initially managed with an intramedullary nail, were subsequently treated by closed, intramedullary exchange nailing with reamed insertion for their femoral nonunion in our center. Seven patients had an infected nonunion as proved by intraoperative cultures. Intervention: Closed, intramedullary exchange nailing with reamed insertion of a larger diameter nail. Main Outcome Measurements: Radiographic and clinical evidence of fracture healing. Results: Thirty-six patients (86%) had their fracture heal without further intervention. The average time to achieve union was 4 months after surgery. Of the 6 cases of exchange nailing failure, 3 were aseptic and 3 were septic. All these 6 patients healed after additional procedures. Lack of immediate weight bearing, open fractures, atrophic/oligotrophic nonunions, and infection were associated with treatment failure. A second nail larger by 2 mm or more than the original nail was associated with a higher success rate. Conclusions: Closed, intramedullary exchange nailing with reamed insertion for femoral shaft nonunions previously treated with intramedullary nails has proved to be a successful sole procedure in most cases. A nail at least 2 mm larger in diameter than the first nail should be used if possible. Risk factors of treatment failure should alert the surgeon to consider an alternative treatment to closed exchange nailing.
26 May 2020 in European Journal of Trauma and Emergency Surgery