Hypothermia in trauma patients is a common condition. It is aggravated by traumatic hemorrhage, which leads to hypovolemic shock. This hypovolemic shock results in a lethal triad of hypothermia, coagulopathy, and acidosis, leading to ongoing bleeding. Additionally, hypothermia in trauma patients can deepen through environmental exposure on the scene or during transport and medical procedures such as infusions and airway management. This vicious circle has a detrimental effect on the outcome of major trauma patients. This narrative review describes the main factors to consider in the co-existing condition of trauma and hypothermia from a prehospital and emergency medical perspective. Early prehospital recognition and staging of hypothermia are crucial to triage to proper care to improve survival. Treatment of hypothermia should start in an early stage, especially the prevention of further cooling in the prehospital setting and during the primary assessment. On the one hand, active rewarming is the treatment of choice of hypothermia-induced coagulation disorder in trauma patients; on the other hand, accidental or clinically induced hypothermia might improve outcomes by protecting against the effects of hypoperfusion and hypoxic injury in selected cases such as patients suffering from traumatic brain injury (TBI) or traumatic cardiac arrest.
Cardiopulmonary resuscitation (CPR) is considered an aerosol-generating procedure. Consequently, COVID-19 resuscitation guidelines recommend the use of personal protective equipment (PPE) during resuscitation. In this simulation of randomised crossover trials, we investigated the influence of PPE on the quality of chest compressions (CCs). Thirty-four emergency medical service BLS-providers performed two 20 min CPR sequences (five 2 min cycles alternated by 2 min of rest) on manikins, once with and once without PPE, in a randomised order. The PPE was composed of a filtering facepiece 3 FFP3 mask, safety glasses, gloves and a long-sleeved gown. The primary outcome was defined as the difference between compression depth with and without PPE; secondary outcomes were defined as differences in CC rate, release and the number of effective CCs. The participants graded fatigue and performance, while generalised estimating equations (GEE) were used to analyse data. There was no significant difference in CC quality between sequences without and with PPE regarding depth (mean depth 54 ± 5 vs. 54 ± 6 mm respectively), rate (mean rate 119 ± 9 and 118 ± 6 compressions per minute), release (mean release 2 ± 2 vs. 2 ± 2 mm) and the number of effective CCs (43 ± 18 vs. 45 ± 17). The participants appraised higher fatigue when equipped with PPE in comparison to when equipped without PPE (p < 0.001), and lower performance was appraised when equipped with PPE in comparison to when equipped without PPE (p = 0.031). There is no negative effect of wearing PPE on the quality of CCs during CPR in comparison to not wearing PPE.
17 September 2024 in The American Journal of Emergency Medicine
Introduction: Out-of-hospital cardiac arrest (OHCA) has a high global incidence and mortality rate, with early defibrillation significantly improving survival. Our aim was to assess the feasibility of autonomous drone delivery of automated external defibrillators (AED) in a non-urban area with physical barriers and compare the time to defibrillate (TTD) with bystander retrieval from a public access defibrillator (PAD) point and helicopter emergency medical services (HEMS) physician performed defibrillation. Methods: This randomized simulation-based trial with a cross-over design included bystanders performing AED retrievals either delivered by automated drone flight or on foot from a PAD point, and simulated HEMS interventions. The primary outcome was the time to defibrillation, with secondary outcomes comparing workload, perceived physical effort, and ease of use. Results: Thirty-six simulations were performed. Drone-delivered AED intervention had a significantly shorter TTD [2.2 (95 % CI 2.0–2.3) min] compared to PAD retrieval [12.4 (95 % CI 10.4–14.4) min] and HEMS [18.2 (95 % CI 17.1–19.2) min]. The self-reported physical effort on a visual analogue scale for drone-delivered AED was significantly lower versus PAD [2.5 (1 – 22) mm vs. 81 (65–99) mm, p = 0.02]. The overall mean workload measured by NASA-TLX was also significantly lower for drone delivery compared to PAD [4.3 (1.2–11.7) vs. 11.9 (5.5–14.5), p = 0.018]. Conclusion: The use of drones for automated AED delivery in a non-urban area with physical barriers is feasible and leads to a shorter time to defibrillation. Drone-delivered AEDs also involve a lower workload and perceived physical effort than AED retrieval on foot.
1 January 2016 in World Journal of Emergency Medicine
In 2013 a General Practitioner Cooperative (GPC) was introduced at the Emergency Department (ED) of our hospital. One of the aims of this co-located GPC was to improve throughput of the remaining patients at the ED. To determine the change in patient flow, we assessed the number of self-referrals, redirection of self-referrals to the GPC and back to the ED, as well as ward and ICU admission rates and length of stay of the remaining ED population. We conducted a four months' pre-post comparison before and after the implementation of a co-located GPC with an urban ED in the Netherlands. More than half of our ED patients were self-referrals. At triage, 54.5% of these self-referrals were redirected to the GPC. After assessment at the GPC, 8.5% of them were referred back to the ED. The number of patients treated at the ED declined with 20.3% after the introduction of the GPC. In the remaining ED population, there was a significant increase of highly urgent patients (P<0.001), regular admissions (P<0.001), and ICU admissions (P<0.001). Despite the decline of the number of patients at the ED, the total length of stay of patients treated at the ED increased from 14 682 hours in the two months' control period to 14 962 hours in the two months' intervention period, a total increase of 270 hours in two months (P<0.001). Introduction of a GPC led to efficient redirection of self-referrals but failed to improve throughput of the remaining patients at the ED.
Heatwaves have been linked to increased risk of mortality and morbidity and are projected to increase in frequency and intensity due to climate change. The current study uses emergency department (ED) data from Australia, Botswana, Netherlands, Pakistan, and the United States of America to evaluate the impact of heatwaves on ED attendances, admissions and mortality. Routinely collected time series data were obtained from 18 hospitals. Two separate thresholds (≥4 and ≥7) of the acclimatisation excess heat index (EHIaccl) were used to define “hot days”. Analyses included descriptive statistics, independent samples T-tests to determine differences in case mix between hot days and other days, and threshold regression to determine which temperature thresholds correspond to large increases in ED attendances. In all regions, increases in temperature that did not coincide with time to acclimatise resulted in increases in ED attendances, and the EHIaccl performed in a similar manner. During hot days in California and The Netherlands, significantly more children ended up in the ED, while in Pakistan more elderly people attended. Hot days were associated with more patient admissions in the ages 5–11 in California, 65–74 in Karachi, and 75–84 in The Hague. During hot days in The Hague, patients with psychiatric symptoms were more likely to die. The current study did not identify a threshold temperature associated with particularly large increases in ED demand. The association between heat and ED demand differs between regions. A limitation of the current study is that it does not consider delayed effects or influences of other environmental factors. Given the association between heat and ED use, hospitals and governmental authorities should recognise the demands that heat can place on local health care systems. These demands differ substantially between regions, with Pakistan being the most heavily affected within our study sample.
7 December 2021 in Journal of the American Heart Association
Background: Helicopter emergency medical services personnel operating in mountainous terrain are frequently exposed to rapid ascents and provide cardiopulmonary resuscitation (CPR) in the field. The aim of the present trial was to investigate the quality of chest compression only (CCO)‐CPR after acute exposure to altitude under repeatable and standardized conditions. Methods and Results: Forty‐eight helicopter emergency medical services personnel were divided into 12 groups of 4 participants; each group was assigned to perform 5 minutes of CCO‐CPR on manikins at 2 of 3 altitudes in a randomized controlled single‐blind crossover design (200, 3000, and 5000 m) in a hypobaric chamber. Physiological parameters were continuously monitored; participants rated their performance and effort on visual analog scales. Generalized estimating equations were performed for variables of CPR quality (depth, rate, recoil, and effective chest compressions) and effects of time, altitude, carryover, altitude sequence, sex, qualification, weight, preacclimatization, and interactions were analyzed. Our trial showed a time‐dependent decrease in chest compression depth ( P =0.036) after 20 minutes at altitude; chest compression depth was below the recommended minimum of 50 mm after 60 to 90 seconds (49 [95% CI, 46–52] mm) of CCO‐CPR. Conclusions: This trial showed a time‐dependent decrease in CCO‐CPR quality provided by helicopter emergency medical services personnel during acute exposure to altitude, which was not perceived by the providers. Our findings suggest a reevaluation of the CPR guidelines for providers practicing at altitudes of 3000 m and higher. Mechanical CPR devices could be of help in overcoming CCO‐CPR quality decrease in helicopter emergency medical services missions. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04138446.