Ravi Prakash

Prof. Ravi Prakash

Department of Electronics Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LLLucy Li
Lucy Li
MCMounia Chakik
Mounia Chakik
RPRavi Prakash
Ravi Prakash
Corrosion is an ever-present phenomena of material deterioration that affects all metal structures. Timely and accurate detection of corrosion is required for structural maintenance and effective management of structural components during their life cycle. The usage of aircraft materials has been primarily driven by the need for lighter, stronger, and more robust metal alloys, rather than mitigation of corrosion. As such, the overall cost of corrosion management and aircraft downtime remains high. To illustrate, $5.67 billion or 23.6% of total sustainment costs was spent on aircraft corrosion management, as well as 14.1% of total NAD for the US Air Force aviation and missiles in the fiscal year of 2018. The ability to detect and monitor corrosion will allow for a more efficient and cost-effective corrosion management strategy, and will therefore, minimize maintenance costs and downtime, and to avoid unexpected failure associated with corrosion. Conventional and commercial efforts in corrosion detection on aircrafts have focused on visual and other field detection approaches which are time- and usage-based rather than condition-based; they are also less effective in cases where the corroded area is inaccessible (e.g., fuel tank) or hidden (rivets). The ability to target and detect specific corrosion by-products associated with the metals/metal alloys (chloride ions, fluoride ions, iron oxides, aluminum chlorides etc.), corrosion environment (pH, wetness, temperature), along with conventional approaches for physical detection of corrosion can provide early corrosion detection as well as enhanced reliability of corrosion detection. The paper summarizes the state-of-art of corrosion sensing and measurement technologies for schedule-based inspection or continuous monitoring of physical, environmental and chemical presence associated with corrosion. The challenges are reviewed with regards to current gaps of corrosion detection and the complex task of corrosion management of an aircraft, with a focused overview of the corrosion factors and corrosion forms that are pertinent to the aviation industry. A comprehensive overview of thin film sensing techniques for corrosion detection and monitoring on aircrafts are being conducted. Particular attention is paid to innovative new materials, especially graphene-derived thin film sensors which rely on their ability to be configured as a conductor, semiconductor, or a functionally sensitive layer that responds to corrosion factors. Several thin film sensors have been detailed in this review as highly suited candidates for detecting corrosion through direct sensing of corrosion by-products in conjunction with the aforementioned physical and environmental corrosion parameters. The ability to print/pattern these thin film materials directly onto specific aircraft components, or deposit them onto rigid and flexible sensor surfaces and interfaces (fibre optics, microelectrode structures) makes them highly suited for corrosion monitoring applications.

28 July 2023 in ACS Sensors
Verified
Journal Article
Closed access
RMRoslyn S. Massey
Roslyn S. Massey
EMErin M. McConnell
Erin M. McConnell
DCDennis Chan
Dennis Chan
MHMatthew R. Holahan
Matthew R. Holahan
MDMaria C. DeRosa
Maria C. DeRosa
RPRavi Prakash
Ravi Prakash

15 June 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
RMRoslyn Massey
Roslyn Massey
SBSiziwe Bebe
Siziwe Bebe
RPRavi Prakash
Ravi Prakash
Organic FET devices offer low-cost manufacturing and simple integration of biorecognition molecules for biosensory applications. In electrolyte gated organic FET (EGOFET) biosensors, a bio-fluid is directly integrated as the OFET gate dielectric for label-free bio-electronic sensors. Critical constraints of these devices are biofouling and organic polymer susceptibility to environmental effects. In this work we solve these issues by implementing a multilayered gate dielectric system in our low-cost OFET biosensor, encompassing the bio-electrolyte and an aptamer-enhanced top gate surface for rapid, high sensitivity detection of cortisol in synthetic buffer solutions. To emphasize crucial architectural and operational differences to EGOFETs, we have termed these devices OEGFETs. We also report a numerical model which can be fitted to predict the behavior of cortisol-specific OEGFET biosensors, and highlighted the distinct advantages of our system compared to the more traditional EGOFET sensors. The specificity of our cortisol biosensor is rigorously tested using two negative control biomolecules, progesterone and cortisone, molecules that structurally resemble cortisol and like cortisol are present in detectable concentrations in saliva. The detectable cortisol concentration range of our OEGFET biosensor is currently identified as 27.3 pM to 27.3μM.

15 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
RMRoslyn Simone Massey
Roslyn Simone Massey
RARishabh Ramesh Appadurai
Rishabh Ramesh Appadurai
RPRavi Prakash
Ravi Prakash
Parkinson’s Disease (PD) is a debilitating neurodegenerative disease, causing loss of motor function and, in some instances, cognitive decline and dementia in those affected. The quality of life can be improved, and disease progression delayed through early interventions. However, current methods of confirming a PD diagnosis are extremely invasive. This prevents their use as a screening tool for the early onset stages of PD. We propose a surface imprinted polymer (SIP) electroimpedance spectroscopy (EIS) biosensor for detecting α-Synuclein (αSyn) and its aggregates, a biomarker that appears in saliva and blood during the early stages of PD as the blood-brain barrier degrades. The surface imprinted polymer stamp is fabricated by low-temperature melt stamping polycaprolactone (PCL) on interdigitated EIS electrodes. The result is a low-cost, small-footprint biosensor that is highly suitable for non-invasive monitoring of the disease biomarker. The sensors were tested with αSyn dilutions in deionized water and in constant ionic concentration matrix solutions with decreasing concentrations of αSyn to remove the background effects of concentration. The device response confirmed the specificity of these devices to the target protein of monomeric αSyn. The sensor limit of detection was measured to be 5 pg/L, and its linear detection range was 5 pg/L–5 µg/L. This covers the physiological range of αSyn in saliva and makes this a highly promising method of quantifying αSyn monomers for PD patients in the future. The SIP surface was regenerated, and the sensor was reused to demonstrate its capability for repeat sensing as a potential continuous monitoring tool for the disease biomarker.

22 June 2022 in Polymers
Verified
Journal Article
Open access
PDF file
DHDane Hintermueller
Dane Hintermueller
RPRavi Prakash
Ravi Prakash
Pristine and doped polyvinylidene fluoride (PVDF) are actively investigated for a broad range of applications in pressure sensing, energy harvesting, transducers, porous membranes, etc. There have been numerous reports on the improved piezoelectric and electric performance of PVDF-doped reduced graphene oxide (rGO) structures. However, the common in situ doping methods have proven to be expensive and less desirable. Furthermore, there is a lack of explicit extraction of the compression mode piezoelectric coefficient (d33) in ex situ rGO doped PVDF composite films prepared using low-cost, solution-cast processes. In this work, we describe an optimal procedure for preparing high-quality pristine and nano-composite PVDF films using solution-casting and thermal poling. We then verify their electromechanical properties by rigorously characterizing β-phase concentration, crystallinity, piezoelectric coefficient, dielectric permittivity, and loss tangent. We also demonstrate a novel stationary atomic force microscope (AFM) technique designed to reduce non-piezoelectric influences on the extraction of d33 in PVDF films. We then discuss the benefits of our d33 measurements technique over commercially sourced piezometers and conventional piezoforce microscopy (PFM). Characterization outcomes from our in-house synthesized films demonstrate that the introduction of 0.3%w.t. rGO nanoparticles in a solution-cast only marginally changes the β-phase concentration from 83.7% to 81.7% and decreases the crystallinity from 42.4% to 37.3%, whereas doping increases the piezoelectric coefficient by 28% from d33 = 45 pm/V to d33 = 58 pm/V, while also improving the dielectric by 28%. The piezoelectric coefficients of our films were generally higher but comparable to other in situ prepared PVDF/rGO composite films, while the dielectric permittivity and β-phase concentrations were found to be lower.

1 January 2022 in IEEE Journal on Flexible Electronics
Verified
Journal Article
Closed access
RMRoslyn S. Massey
Roslyn S. Massey
RPRavi Prakash
Ravi Prakash
Label-free, organic field-effect transistor (OFET)-based biosensors have often overlooked a key challenge to commercialization, i.e., process integration. Many promising literature point-of-care (PoC) prototypes are poor integration candidates due to short shelf life, rigid form factor, and reliance on specialized data collection. Our flexible organic electrolyte-gated FET (OEGFET) sensor device architecture is designed to mitigate some of these integration challenges using a novel low temperature, low-cost fabrication process. As a result of the new process, we observed significant improvements in sensor operating parameters over our previous OEGFETs printed using conventional materials, including a 75% reduction in operating voltage (<5 V), $10\times $ superior cortisol detection limit, preserved electrical characteristics (<20% reduction), and laboratory shelf life of over 15 days. We observed excellent repeatability and a predictable distinction between concentration versus output current responses for synthetic samples and complex media, such as spiked saliva supernatant. The device demonstrated a broad detection range of 0.276 pM–27.6 $\mu \text{M}$ for cortisol samples, encompassing the salivary cortisol physiological range. Device specificity to cortisol was observed with progesterone samples, with highly repeatable results and predictable distinctions between binding and nonbinding assays. The fully flexible OEGFET is the first example of an electrolyte-gated OFET biosensor device with integrated soft microfluidic channels, validated using both synthetic and spiked saliva samples.