Yang Li

Dr. Yang Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2020 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
PDF file
YLYang Li
Yang Li
XSXing Shen
Xing Shen
XKXiping Kou
Xiping Kou
LYLi Yu
Li Yu
In the low-temperature environment, temperature reduction affects the properties and actuation performance of the piezoelectric stack. To solve this problem, a practical and effective heating and insulation structure, based on the working characteristics of the piezoelectric stack, is proposed in this article. Thermal conductivity models of the piezoelectric stack under two heating modes—whole heating and local heating—are developed and validated by finite element simulation analysis. The heating and insulation structure has been built according to the theoretical model, and the experimental test is conducted to measure the temperature and property variation of the piezoelectric stack, as well as its actuation performance with ambient temperature drop. The experimental results show that the theoretical and simulation results are consistent with the experimental results, as the maximum temperature difference between them is 4.3°C, which indicates the correctness and accuracy of the theoretical and finite element models. Besides, the properties and the actuation performance are almost unchanged within the range from 10°C to −70°C, which verifies the effectiveness and feasibility of the heating and insulation structure. Consequently, this structure can be redesigned according to the principles proposed in this article, and widely used in protecting piezoelectric stacks of different sizes and low-temperature environments; the application range of the piezoelectric stack can also be extended to lower temperatures.

14 December 2018 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
YLYang Li
Yang Li
Xing ShenXing Shen
Xing Shen
YCYuchen Chen
Yuchen Chen
A refined resonance method, which is based on the theoretical model of a piezoelectric stack under constraint boundary condition is developed and proposed to measure the properties of piezoelectric stack which are relevant to the prestress. The method can transcend the limitation of the conventional resonance method in which the piezoelectric stack under measurement must be free to vibrate. An experimental setup has been designed and built according to the theoretical model, and the properties of a piezoelectric stack are characterized for a wide range of prestress to demonstrate the validity of this method. The experimental results show that properties including relative dielectric constant, piezoelectric constant, electromechanical coupling coefficient and elastic compliance exhibit strong pressure dependence. Among them, the piezoelectric constant measured by this method is compared with measurement by traditional static method, and the deviation between the refined and conventional method is less than 3.25% for a pressure range from 0 to 6 MPa, which indicates that the experimental results of the two test methods are consistent and the presented theoretical model for piezoelectric stack under preload manifests accuracy by means of the correctness and feasibility verification of the proposed method though cross validation and relevant discussions. Consequently, the refined resonance method could be extended to analyze the variation of piezoelectric stack properties that occurs under operational conditions with varied pressure.

10 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YLYang Li
Yang Li
YZYongping Zheng
Yongping Zheng
LSLeipeng Song
Leipeng Song
ZYZhefan Yao
Zhefan Yao
HZHui Zhang
Hui Zhang
XXXinjian Xiang
Xinjian Xiang
Under low-temperature conditions, the load-bearing capacity of piezoelectric stacks arises from coupled thermo-electro-mechanical interactions, with temperature fluctuations, compressive prestress, and excitation voltage critically modulating performance. This study introduces an integrated measurement platform to systematically quantify these interdependencies, employing a cantilever-based sensing mechanism where bending strain serves as a direct metric of load-bearing capacity. A particle swarm-optimized theoretical framework guides the spatial configuration of actuators and sensors, maximizing strain signal fidelity while suppressing noise interference. Experimental characterization reveals three key findings: 1. Voltage-dependent linear enhancement of load-bearing capacity across all operational regimes, unaffected by thermal or mechanical variations; 2. Prestress-induced amplification (79–90% increase from 0 to 6 MPa) and thermally driven attenuation (15–30% reduction from 20 to −70 °C) of static performance; 3. Frequency-dependent degradation (1–6 Hz) in dynamic load-bearing capacity. The methodology establishes a robust foundation for designing multiphysics-compatible instrumentation systems, enabling precise evaluation of smart material behavior under extreme coupled-field conditions.

1 December 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YLYang Li
Yang Li
XXXinjian Xiang
Xinjian Xiang
ZFZhengshun Fei
Zhengshun Fei
BHBingqiang Huang
Bingqiang Huang
YZYongping Zheng
Yongping Zheng
Xing ShenXing Shen
Xing Shen
In a low-temperature environment, the actuation performance of the piezoelectric stack results from the synergic action of the thermo-electro-mechanical field; the actuation performance is influenced by the change in temperature, compressive preload, and excitation voltage. A special and novel instrumentation system is proposed and developed in this study to measure the relationship between the actuation performance of the piezoelectric stack and the change in temperature, preload, and voltage. The bending strain of the cantilever beam driven by the piezoelectric stack reflects its actuation performance, and the corresponding theoretical model is established to optimize the experimental conditions and maximize the strain and signal-to-noise ratio. Based on the experimental results, it can be seen that the actuation performance of the piezoelectric stack increases linearly with the excitation voltage under different temperatures and preload conditions. The static actuation performance increased by 79%–90% when the prestress increased from 0 to 6 MPa, corresponding to a decrease of 15%–30% when the temperature decreased from 20 to −70 °C, and the dynamic actuation performance decreased with an increase in the frequency of the excitation voltage. Consequently, the design methods and ideas are informative to develop an instrumentation system that can measure the influence of thermo-electro-mechanical synergistic effects on the actuation performance of piezoelectric stacks under different temperatures, preloads, and voltages.

28 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YLYang Li
Yang Li
DHDexin Hou
Dexin Hou
FLFeng Li
Feng Li
LHLianghui Huang
Lianghui Huang
ZHZhihua Huang
Zhihua Huang
XXXinjian Xiang
Xinjian Xiang
The thermal properties of bipolar plates, being key elements of polymer electrolyte membrane fuel cells, significantly affect their heat conduction and management. This study employed an innovative approach known as a heat flow loop integral method to experimentally assess the in-plane thermal conductivity of graphite bipolar plates, addressing the constraints of traditional methods that have strict demands for thermal stimulation, boundary or initial conditions, and sample size. This method employs infrared thermal imaging to gather information from the surface temperature field of the sample, which is induced by laser stimulation. An enclosed test loop on the infrared image of the sample’s surface, situated between the heat source and the sample’s boundary, is utilized to calculate the in-plane heat flow density by integrating the temperature at the sampling locations on the loop and the in-plane thermal conductivity can be determined based on Fourier’s law of heat conduction. The numerical simulation analysis of the graphite models and the experimental tests with aluminum have confirmed the precision and practicality of this method. The results of 1060 aluminum and 6061 aluminum samples, each 1 and 2 mm in thickness, show a deviation between the reference and actual measurements of the in-plane thermal conductivity within 4.3% and repeatability within 2.7%. Using the loop integral method, the in-plane thermal conductivities of three graphite bipolar plates with thicknesses of 0.5 mm, 1 mm, and 1.5 mm were tested, resulting in 311.98 W(m·K)−1, 314.41 W(m·K)−1, and 323.48 W(m·K)−1, with repeatabilities of 0.9%, 3.0%, and 2.0%, respectively. A comparison with the reference value from the simulation model for graphite bipolar plates with the same thickness showed a deviation of 4.7%. The test results for three different thicknesses of graphite bipolar plates show a repeatability of 2.6%, indicating the high consistency and reliability of this measurement method. Consequently, as a supplement to existing technology, this method can achieve a rapid and nondestructive measurement of materials such as graphite bipolar plates’ in-plane thermal conductivity.

27 June 2026 in AIAA Journal
Verified
Journal Article
Closed access
YLYang Li
Yang Li
XXXinjian Xiang
Xinjian Xiang
ZFZhengshun Fei
Zhengshun Fei
YZYongping Zheng
Yongping Zheng
LSLeipeng Song
Leipeng Song
YJYongping Jiang
Yongping Jiang
Effective control of cantilever sting vibration is essential for preventing shaft breakage and ensuring the safety of cryogenic wind tunnels. However, the performance of piezoelectric stack actuators, a common solution, is severely limited by ultralow temperatures, which reduces their vibration damping effectiveness. To address this, a tailored thermal control structure is proposed. Heat conduction models for both entire and localized heating schemes were developed and validated through numerical simulation. The structure was optimized to significantly improve the actuator’s axial temperature uniformity. A corresponding piezoelectric-based sting vibration damping system was developed and tested in both ambient and cryogenic liquid nitrogen environments. Results show that the optimized thermal control maintained consistent first-order frequency and damping ratio values, demonstrating that the actuation performance was unaffected by ultralow temperatures. Furthermore, comparative tests under cryogenic conditions demonstrated that the thermal control structure maintains actuator performance, while unprotected operation results in significant degradation with temperature decline. This work provides the first validated solution for reliable piezoelectric operation in extreme cryogenic conditions, proving the efficacy of the proposed thermal management approach. The methodology effectively extends piezoelectric applications to cryogenic wind tunnels and other ultralow temperature settings, enabling accurate and safe aeroelastic testing for future aircraft design.