Knies Knies

Dr. Knies Knies


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2022 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Open access
KKKnies Knies
Knies Knies
Erik TeskeErik Teske
Erik Teske
HKHans Kooistra
Hans Kooistra
Objectives: Home blood glucose monitoring using a portable blood glucose meter is important in the management of feline diabetes mellitus, but taking blood samples may be stressful for owners and cats. A flash glucose monitoring system measuring interstitial glucose, such as the FreeStyle Libre, overcomes some of these drawbacks. The aim of this study was to evaluate the practical use and analytical and clinical accuracy of the FreeStyle Libre in 41 client-owned diabetic cats. Methods: In this prospective study, interstitial glucose concentrations were measured with the FreeStyle Libre and compared with blood glucose concentrations measured with a portable blood glucose meter (AlphaTRAK) on days 1, 7 or 8 and 14 after application of the device. Cat behaviour during application, location, skin reaction at the attachment site and owner satisfaction were assessed. Accuracy was determined by fulfilment of ISO 15197:2013 criteria, including Bland–Altman plotting and error grid analysis. Results: Placing the device was easy, with 70% of cats showing no reaction. Most sensors were placed on the thoracic wall. Skin reactions at the attachment site were not present or mild in almost all cats. Owners were very satisfied with the use of the FreeStyle Libre. Median functional life of the sensor was 10 days (range 1–14). Good correlation was found between interstitial and blood glucose measurements (rho[r] = 0.88, P <0.0001). Fifty-three percent of interstitial glucose concentrations were within a maximum deviation of 15% from blood glucose concentrations and 92.7% were within the safe risk zones 0 and 1 of the surveillance error grid. Conclusions and relevance: The flash glucose monitoring system was easy to use and owners of diabetic cats were satisfied with its use. Although the device did not completely fulfil ISO requirements, it is sufficiently accurate for glucose monitoring in diabetic cats.

6 June 2023 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Open access
KKKnies Knies
Knies Knies
HKHans S Kooistra
Hans S Kooistra
Erik TeskeErik Teske
Erik Teske
Objectives: Systemic arterial hypertension is increasingly recognised and can have serious adverse consequences in cats. Unfortunately, the act of measuring blood pressure itself may cause an increase in blood pressure, known as situational hypertension. It is currently unknown how often this phenomenon occurs. The aim of this study was to evaluate the prevalence of persistent hypertension and situational hypertension in an elderly population of cats in a first-opinion clinic and to assess which factors were associated with systolic hypertension. Methods: In this prospective study, systolic blood pressure was measured in 185 cats aged ⩾10 years using the Doppler sphygmomanometry method according to the recommendations of the American College of Veterinary Internal Medicine consensus statement. Age, sex, body weight, body condition score, position during blood pressure measurement and apparent stress level were assessed. If a systolic blood pressure >160 mmHg was found, measurements were repeated to evaluate if persistent hypertension or situational hypertension was present. The first set of blood pressure measurements were used for all the statistical analyses. Results: The median systolic blood pressure for this population was 140 mmHg. The prevalence of persistent hypertension was at least 14.6% and situational hypertension at least 5.4%. Factors significantly associated with hypertension were age, higher apparent stress levels and a sitting position during measurement. Sex, body weight or body condition score did not significantly influence systolic blood pressure. Conclusions and relevance: Both persistent hypertension and situational hypertension are common in elderly cats. There are no reliable parameters to distinguish between the two, underlining the importance of a standard protocol and repeating measurements during a follow-up visit when hypertension is found. Age, demeanour and body position during blood pressure measurement influenced blood pressure in this population of elderly cats.

3 December 2025 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Open access
KKKnies Knies
Knies Knies
ASAnnechien I Smalbroek
Annechien I Smalbroek
AKAstrid L Kamp
Astrid L Kamp
MAMarleen Assink
Marleen Assink
JOJohanna Onis-Jackson
Johanna Onis-Jackson
IGIngeborg Marianne Van Geijlswijk
Ingeborg Marianne Van Geijlswijk
Objectives: The study aimed to assess the clinical efficacy, safety and outcomes of legally prescribed and compounded GS-441524, with or without prior remdesivir, in cats with confirmed or highly suspected feline infectious peritonitis (FIP) in the Netherlands. A standardised diagnostic and treatment protocol was used to evaluate clinical response, adverse effects and prognostic factors. Methods: This prospective, multicentre study included 127 client-owned cats with FIP, enrolled between June and November 2023 from three Dutch veterinary clinics. Diagnosis followed American Association of Feline Practitioners (AAFP)/EveryCat guidelines, incorporating clinical findings, laboratory data, imaging, cytology and RT-qPCR performed on either fine-needle aspirates or effusion. Cats were treated for a minimum of 12 weeks with oral GS-441524, with some initially receiving intravenous remdesivir before transitioning to oral therapy. Dosing was based on disease form (effusive, non-effusive, ocular, neurological). Follow-up included physical examinations and clinicopathological monitoring. Descriptive statistics, Kaplan–Meier survival analysis and Cox regression were used for data analysis. Results: Of the 127 cats, 55.9% had effusive, 19.7% non-effusive, 16.5% ocular and 7.9% neurological FIP; 21.3% showed mixed forms. Most cats were aged under 2 years (87.4%), male (77.2%) and purebred (60.6%). Common clinical signs included lethargy (93%) and inappetence (83%). Overall survival was 78%. Ocular FIP had the highest survival (100%), while neurological FIP had the lowest (60%). Elevated serum bilirubin and creatinine concentrations at presentation were associated with reduced survival. Adverse effects were generally mild and transient, with vomiting (33%) and diarrhoea (29%) most commonly reported. Conclusions and relevance: This study confirms that GS-441524, with or without prior remdesivir, is an effective and well-tolerated treatment for naturally occurring FIP. Clinical improvement was typically rapid; resolution of laboratory abnormalities took longer. These findings support the legal use of GS-441524 in feline practice and highlight the need for further research to refine treatment protocols.

4 July 2025 in Pathogens
Verified
Journal Article
Open access
PDF file
Petra CernaPetra Cerna
Petra Cerna
KKKnies Knies
Knies Knies
MAMarleen Assink
Marleen Assink
SESamantha Evans
Samantha Evans
Séverine TaskerSéverine Tasker
Séverine Tasker
RLR. Michael Lappin
R. Michael Lappin
Feline infectious peritonitis (FIP) is caused by mutated feline coronaviruses. Immune-mediated hemolytic anemia (IMHA) arises due to immune-mediated erythrocyte destruction and can be non-associative or associative with diseases such as FIP. Records of cats with FIP were reviewed to find those with associative IMHA based on exclusion of other causes of anemia and a positive saline agglutination test and/or Coombs test. The inclusion criteria were met for 45 cats (26 (58%) cats with effusive and 19 (42%) with non-effusive FIP). Median hematocrit was 18% (interquartile range [IQR] 13–20). Anemia was non-regenerative in 36 (80%) cats and regenerative in 5 (11%) cats; 4 (9%) cats had no reticulocyte count available. Concurrent thrombocytopenia was present in 18 (40%) cats. All 45 cats were treated with nucleoside analogs, and 44 (98%) cats with glucocorticoids; in 5 (11%) cats, glucocorticoids were added after starting antiviral treatment due to persistent anemia. Median follow-up was 72 days (IQR 14–246); at the time of last follow-up 33 (73%) cats had survived while 12 (27%) had died or were euthanized. Of the 33 surviving cats, 17 achieved remission of both FIP and IMHA. In three cats, FIP remission was achieved, but IMHA relapsed; in one of these, IMHA relapsed twice. FIP relapsed without IMHA in two cats, and both FIP and IMHA relapsed in one cat. In 9 cats the antiviral and glucocorticoid treatment is still ongoing at the time of the publication. Although FIP is likely an uncommon cause of associative IMHA, as more cats with FIP are treated with antiviral therapy, it is important to consider IMHA as a possible cause of anemia in cats with FIP.

28 March 2024 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Open access
KKKnies Knies
Knies Knies
Erik TeskeErik Teske
Erik Teske
HKHans Kooistra
Hans Kooistra
Objectives: Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats. Methods: In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed. Results: There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP. Conclusions and relevance: Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.

20 August 2026 in Journal of Feline Medicine and Surgery
Verified
Journal Article
Open access
KKKnies Knies
Knies Knies
NHNikki Hofman
Nikki Hofman
JJJohanna Jackson-Onis
Johanna Jackson-Onis
EBEls Broens
Els Broens
Erik TeskeErik Teske
Erik Teske
Objectives: The aim of the present study was to evaluate the agreement of a commercially available point-of-care (POC) feline coronavirus (FCoV) quantitative RT-PCR (RT-qPCR) assay and external laboratories’ RT-qPCR testing in cats with effusive and non-effusive feline infectious peritonitis (FIP), and in cats with other diseases presenting with similar clinical signs. Methods: Client-owned cats suspected of having FIP were enrolled with owner consent. Effusions and ultrasound-guided fine-needle aspirates (FNAs) from the liver, spleen or mesenteric lymph nodes were collected, split and analysed using both a POC RT-qPCR and an external laboratory RT-qPCR. FIP was diagnosed based on American Association of Feline Practitioners/EveryCat guidelines. Sensitivity and negative predictive values were calculated, agreement assessed with Cohen’s kappa, paired differences tested with McNemar’s test and correlation of crossing point (Cp) values analysed using Pearson’s coefficient and paired t -tests. Results: A total of 100 cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% POC, 92.3% external) and lower in FNAs (63.3–64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle). Conclusions and relevance: The POC FCoV RT-qPCR assay is a practical and reliable tool and shows very good agreement with external reference laboratory RT-qPCR testing. FNAs remain useful when effusions are unavailable but carry a higher risk of false negatives, likely due to low viral loads and heterogeneous distribution. POC care testing offers rapid turnaround, supporting timely clinical decision-making, but results must be interpreted alongside clinical presentation and other diagnostics.