Primary stability of orthodontic miniscrew system is of great importance in maintaining stable anchorage during a treatment period. Thus, this study aimed to examine whether the thread shape of orthodontic miniscrew had an effect on its mechanical stability in bone. Three different types of miniscrews (type A and B with a regular thread shape; type C with a novel thread shape) were placed in artificial bone block with different artificial cortical bone thickness of 1.5, 2.0 and 3.0 mm. Values of maximum insertion torque (MIT), removal torque (RT), torque ratio (TR), screw mobility, static stiffness (K), dynamic stiffness (K∗) and energy dissipation (tan δ) ability were assessed for each miniscrew system. The MIT, RT, TR and K of type C miniscrew were significantly greater than those of type A and B miniscrews when the miniscrews were placed in the thinner artificial bone. Furthermore, the TR value of type C miniscrew was more than 1, indicating the MRT value was larger than the MIT value in the novel miniscrew. The values of K∗ and tan δ were almost similar among the three types of miniscrews. The miniscrew with a novel thread shape showed a higher initial stability compared to those with a regular thread shape. Thus, in order to obtain a sufficient initial stability, it is important to select the type of screw thread that is appropriate for the thickness of the cortical bone.
29 June 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Cortical bone thickness is assumed to be a major factor regulating miniscrew stability. We investigated stress distribution in two miniscrews with different thread shapes (type A and B) and in cortical bone of three different thicknesses using three-dimensional (3D) finite element (FE) models. More specifically, 3D FE models of two different miniscrews were created and placed obliquely or vertically into a cylindrical bone model representing different cortical bone thicknesses. When force was applied to the miniscrew, the stress distribution on the screw surface and in the peri-implant bone was assessed using FE methodology. Miniscrew safety was evaluated using a modified Soderberg safety factor. Screw head displacement increased with a decrease in cortical bone thickness, irrespective of screw type. The smallest minimum principal stresses on the screw surfaces remained constant in type A miniscrews on changes in cortical bone thickness. Minimum principal stresses also appeared on the cortical bone surface. Lower absolute values of minimum principal stresses were seen in type A miniscrews when placed vertically and with upward traction in obliquely placed type B miniscrews. Both miniscrews had acceptable safety factor values. Taken together, orthodontists should select and use the suitable miniscrew for each patient in consideration of bone properties.
We aimed to elucidate stress distribution in miniscrews and the surrounding bone when miniscrews inserted at different depths were implanted vertically or obliquely. The distributions of the equivalent stress on the screw surface and the minimum principal stress in the surrounding bone were calculated using finite element models. When the miniscrews were inserted vertically and obliquely, screw head displacement, greatest equivalent stress on the miniscrew surface, and absolute value of minimum principal stresses in the surrounding bone decreased with increasing insertion depth. Stresses in the obliquely inserted miniscrew with upward traction were smaller than in other insertion conditions, irrespective of insertion depth. With the application of orthodontic force, stress distribution around the miniscrew and surrounding bone is closely related to the insertion depth and insertion angle, which mutually affect each other. In particular, the obliquely inserted miniscrew with upward traction might be the most secure against screw failure and fracture.
We successfully treated a 37-year-old male who had skeletal open bite with severe amelogenesis imperfecta (AI) with orthodontics, compression osteogenesis, and prosthodontics. The patient was diagnosed with severe anterior open bite caused by severe AI. Corticotomy was performed on both buccal and palatal sides of the molar regions, and anchor plates were placed onto the bilateral zygomatic buttress and the center of the hard palate. After corticotomy, posterior maxillary segments were moved 3.5 mm superiorly to correct skeletal open bite with elastic chains. After 8-month, overbite had decreased by 2.0 mm. After further 5 months of prosthodontic preparation, orthodontic appliances were removed, and provisional crowns were set on all teeth. The anterior open bite was corrected, and ideal occlusion with a Class I molar relationship was achieved. The upper first molars were intruded 3.5 mm, resulting in 3.0o counter-clockwise rotation of the mandible. The total active treatment period was 16 months. Acceptable occlusion with a good facial profile was well maintained throughout the 8-year retention period. Our results indicate long-term stability after interdisciplinary treatment combining orthodontics, oral surgery, and prosthodontics in a patient with severe anterior open bite and AI.