A sapphire optical fiber, with an internal cladding and an array of type-II Bragg gratings inscribed into it, was tested to temperatures up to 1300°C. The sapphire fiber was interrogated with an optical frequency domain reflectometer, using the Bragg gratings in the fiber as simply “enhanced Rayleigh scatter.” The sapphire fiber was able to produce consistent temperature measurements up to 1300°C. Above 1000°C, small oscillations appeared in the measured temperature, which we believe were a consequence of vibrational strains on the fiber that were due to air currents within the furnace. A calibration was added to the optical frequency domain reflectometer that assumed a linear relationship between the fiber temperature and fiber length. We used this calibration to correlate phase shifts that were measured using the optical frequency domain reflectometer to temperatures that were measured using a B-type thermocouple. This calibration could be improved to increase the accuracy of the temperature measurements.
The focus of this work is to extend optical frequency domain reflectometry sensing to sapphire optical fiber, by creating a cladding in the fiber. A cladding was created by irradiating a sapphire optical fiber, which was surrounded by an annulus of Li-6 enriched lithium carbonate (Li 2 CO 3 ) powder, in The Ohio State University Research Reactor. The 6 Li(n, α) 3 H reaction created high energy alpha particles and tritons that irradiated the fiber simultaneously to a depth of 24 microns along the entire periphery of the sapphire fiber, thereby slightly reducing the index of refraction in the fiber's periphery and creating a cladding within the fiber. Transmitted light intensity profiles show that the ion implanted cladding made the fiber's intensity profile nearly single mode. The cladding survived to the highest temperature that was tested (1500°C). The cladding made the fiber sufficiently single mode that the cladded sapphire fiber, when read out with an optical backscatter reflectometer, produced distributed temperature measurements along the entire length of the fiber.
26 February 2018 in Journal of the American Ceramic Society
Experiments were performed to test fiber optic temperature sensors under thermal conditions similar to those that would be experienced in the transient reactor test facility (TREAT) at the Idaho National Laboratory. Specifically, four single-mode optical fiber sensors were dropped into a pre-heated furnace to simulate a step temperature transient, for steps from room temperature to indicated furnace temperatures, ranging from 700 °C to 1100 °C. The four fibers were a standard SMF-28 fiber, a fiber with inscribed type-I fiber Bragg gratings (FBGs), and two fibers with inscribed type-II FBGs. The two type-II FBG fibers were different in the initial backscatter signal of the gratings; one fiber had gratings with greater backscatter reflection than the other. The type-I FBG sensor and standard SMF-28 sensor measured temperature for temperature transients with a final temperature of 700 °C. The low reflection type-II FBG sensor measured temperature transients with final temperatures up to 950 °C. The high-reflection type-II FBG sensor successfully measured temperature for short times with final temperatures up to 1050 °C. For long times at 1050 °C, there was a drift in the temperature sensing. We conclude that the high-reflection type-II FBG sensor would perform acceptably for application in the thermal environment of TREAT, or for other step temperature transients from room temperature to final temperatures up to 1000 °C.
The nuclear security community has long been interested in the identification and quantification of nuclear material signatures to understand a material’s provenance, use, and ultimate application. New forensics signatures and methods intended for non-traditional or advanced nuclear fuel applications require fuel irradiation experiments to demonstrate viability and validity. Integral fuel irradiations have historically required significant costs and long timelines to design, irradiate, and characterize. This paper describes how a recently developed nuclear fuel irradiation testbed can be used to provide a low cost, rapid turnaround, modular test environment for irradiation and evaluation of nuclear fuel specimens for nuclear security applications. The irradiation testbed houses six small ‘MiniFuel’ samples within hermetically sealed capsules inside targets that can be removed in between each ∼25-day operating cycle of the High Flux Isotope Reactor (HFIR). As many as nine targets can be irradiated using a single irradiation position (reflector region) in HFIR, allowing for varying irradiation temperatures and burnups. A suite of hot cell capabilities have been established to perform post-irradiation examination for measuring performance (e.g., fuel swelling, fission gas release) and facilitating experiment disassembly for subsequent property measurements, microstructural analysis, or chemical assay. This new testbed allows fuel irradiations to be conducted on an accelerated timeframe to enable rapid proof of concept testing and to provide reference material for nuclear fuel security applications. Recent applications using this testbed include the testing of isotopic taggants in UO2 fuel (intentional forensics), testing of U-10Mo fuel for down-conversion of highly enriched uranium–fueled reactors, and the production of irradiated UO2 fuel material for signature analysis of its isotopic composition (plutonium, fission gases, etc.).