As the global energy structure transitions towards cleaner sources, large-scale integration of wind power has become a trend for modern power systems. However, the impact of low-inertia power electronic converters and the fault propagation effects at critical nodes pose significant challenges to power system stability. To this end, a Kuramoto-like model analysis method, considering node importance, is proposed in this paper. First, virtual node technology is utilized to optimize the power grid topology model. Then an improved PageRank algorithm embedded by a critical node identification method is proposed, which simultaneously considers transmission efficiency, coupling transmission probability, and voltage influence among nodes. On this basis, the traditional uniform coupling assumption is eliminated, thereby reallocating the coupling strength between critical nodes. In addition, the Kron method is applied to simplify the power grid model, constructing a hybrid Kuramoto-like model that integrates second-order synchronous machine oscillators and first-order wind power oscillators. Based on this model, the transient stability of the wind power integrated power system is analyzed. Finally, through estimating the attraction region range of the stable equilibrium point, a transient stability criterion is proposed for fault limit removal time assessment. The simulation results of the improved IEEE 39-bus system show that coupling strength optimization based on node importance reduces the system’s average critical coupling strength by 17%, significantly improving synchronization robustness. Time-domain simulations validate the accuracy of the method, with the relative error of fault removal time estimation controlled within 10%. This research provides a new analytical tool for transient stability analysis of wind power integration.
Synchronous stability is crucial for the safety and operation of AC power systems. However, most of the current researches focused on the stability of grid-connected converters, and that of renewable equipment still lacked. In this paper, the impact of the additional inertia control (AIC) on the permanent magnet synchronous generator (PMSG) is studied. It is found that with the AIC, the system dominant dynamics shifts from the electromagnetic to electromechanical timescales. This paper develops a simplified model for the single-PMSG infinite-bus system with the AIC within the electromechanical timescale, and reveals the transient synchronization stability mechanism from three aspects: the machine-network interface, transient dominant variable, and interaction between the synchronous loop and the power imbalance loop. Finally, this paper analyzes the swing characteristics of the PMSG system, and uncovers the relationship between the energy transmission and synchronization. These findings could provide improved insights into the synchronous stability mechanism of renewable-dominated new-type power systems.