Berhan Pirimoglu

Dr. Berhan Pirimoglu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in The Eurasian Journal of Medicine
Verified
Journal Article
Open access
BPBerhan Pirimoglu
Berhan Pirimoglu
RSRecep Sade
Recep Sade
HOHayri Ogul
Hayri Ogul
MKMecit Kantarci
Mecit Kantarci
SESuat Eren
Suat Eren
ALAkın Levent
Akın Levent
The purpose of this article was to provide an up-to-date review on the spectrum of new imaging applications in the practice of radiology. New imaging techniques have been developed with the objective of obtaining structural and functional analyses of different body systems. Recently, new imaging modalities have aroused the interest of many researchers who are studying the applicability of these modalities in the evaluation of different organs and diseases. In this review article, we present the efficiency and utilization of current imaging modalities in daily radiological practice.

15 February 2020 in Turkish Journal of Gastroenterology
Verified
Journal Article
Closed access
BPBerhan Pirimoglu
Berhan Pirimoglu
RSRecep Sade
Recep Sade
GPGökhan Polat
Gökhan Polat
AIAli İşLek
Ali İşLek
MKMecit Kantarci
Mecit Kantarci
Background/Aims: Proton density fat fraction (PDFF) magnetic resonance (MR) imaging can be a useful technique for volumetric measurements of liver fat. The purpose of our study was to evaluate the correlation between liver fat fraction (LFF) and aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels in children who are overweight and obese. Materials and Methods: Overall, 25 children, aged 9-17 years, were included. Patients with a body mass index (BMI) z-score between 85-95th percentile (12 of 25 patients) were assigned to the overweight group, and those with BMI z-score above 95th percentile (13 of 25 patients) were assigned to the obese group. The control group comprised 12 healthy children with BMI z-score below 85th percentile. Liver fat fraction measurements were performed on 3D volume measurement workstation by using PDFF magnetic resonance (MR) images. Spearman’s correlation coefficients between liver fat fraction and AST and ALT levels were evaluated individually for overweight, obese, and control groups. Receiver operator characteristics (ROC) analysis was also performed. Results: In the overweight and obese groups, the liver proton density fat fraction and AST levels had a strong correlation (r=0.716, p<0.001). In addition, the LFF and ALT levels demonstrated a strong correlation (r=0.878, p<0.001). ROC analysis ascertained an optimal liver fat fraction threshold of 114 for predicting AST level (sensitivity=75%, specificity=89%). ROC analysis ascertained an optimal LFF threshold of 114 for predicting ALT level (sensitivity=80%, specificity=90%). Conclusion: Our results indicate a strong correlation between LFF values and AST and ALT levels in children who are overweight and obese.

1 May 2018 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
BPBerhan Pirimoglu
Berhan Pirimoglu
RSRecep Sade
Recep Sade
MSMuhammed Sedat Sakat
Muhammed Sedat Sakat
HOHayri Ogul
Hayri Ogul
ALAkin Levent
Akin Levent
MKMecit Kantarci
Mecit Kantarci
Objectives The objective of this study was to evaluate image quality of low dose in noncontrast paranasal sinus computed tomography (CT) using single volumetric 320-row multidetector CT technique. Methods The low-dose protocol including tube voltage of 135 kV and tube current of 5 mAs was chosen based on results of the present phantom study. Forty-six patients were assigned to control group with factory standard settings (120 kVp, 75 mAs), and 46 patients were assigned to study group and underwent noncontrast CT of paranasal sinus with low-dose protocol using single volumetric 320-row multidetector CT device. Objective and subjective image qualities were performed. Results Effective radiation dose calculated for control group scans was 0.45 (SD, 0.39) mSv. It was 0.038 (SD, 0.004) mSv for study group scans. The effective radiation dose of study group was statistically significant lower than control group (P < 0.001). Conclusions Noncontrast paranasal sinus CT imaging can be performed at very low radiation exposure maintaining high image quality with 135 kVp and 5 mAs.

1 November 2018 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
BPBerhan Pirimoglu
Berhan Pirimoglu
MKMecit Kantarci
Mecit Kantarci
Schwannoma is usually an uncommon benign encapsulated slow-growing neural tumor that originates from Schwann cells of peripheral, cranial, and autonomic nerves. It constitutes 1% to 8% of all head and neck neoplasms. Extracranial schwannoma are very rarely seen originating from the infraorbital nerve. Most of the schwannomas are usually solitary and not associated with NF1. The typical presentation is a slow-growing soft-tissue mass. Treatment of schwannoma is surgical resection.

1 March 2019 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
BPBerhan Pirimoglu
Berhan Pirimoglu
RSRecep Sade
Recep Sade
AIAli Islek
Ali Islek
MKMecit Kantarci
Mecit Kantarci
Objectives: The purpose of this study was to evaluate liver fat fraction and subcutaneous and visceral fat volumes using new magnetic resonance imaging in normal-weight, overweight, and obese children. Methods: Patients at below the 85th percentile of body mass index (BMI) z score (5/25 patients) were assigned to the normal-weight group; patients between 85th and 95th percentile of BMI z score (9/25 patients) were assigned to the overweight group, and patients above the 95th percentile of BMI z score (11/25 patients) were assigned to the obese group. Liver fat fraction and subcutaneous and visceral fat volumes were measured on 3-dimensional volume measurement workstation. Results: Liver fat fraction and subcutaneous fat volume had weak correlation ( r = 0.18, P = 0.411). Liver fat fraction and visceral fat volume revealed weak correlation ( r = 0.25, P = 0.672); visceral and subcutaneous fat volume demonstrated strong correlation ( r = 0.67, P = 0.047). Conclusions: There is strong correlation between subcutaneous fat volume and visceral fat volume in overweight and obese children.

24 September 2018 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
BPBerhan Pirimoglu
Berhan Pirimoglu
RSRecep Sade
Recep Sade
MSMuhammed Sedat Sakat
Muhammed Sedat Sakat
GPGokhan Polat
Gokhan Polat
MKMecit Kantarci
Mecit Kantarci
320-row volume computed tomography (CT) allows CT dose to be reduced while maintaining image quality. To evaluate image quality of low-dose non-contrast temporal bone CT using single volumetric 320-row multidetector CT technique. A total of 125 patients were included in our study. Two low-dose protocols, including 135 kV tube voltage with 5 mAs tube current and 80 kV tube voltage with 5 mAs tube current, were chosen based on results of present phantom study. For evaluating subjective image quality, conspicuity of anatomic landmarks were assigned a score using a five-point scale. Objective image quality analysis was performed by analyzing regions of interest on axial soft-tissue and bone reconstructions. Effective dose was calculated from dose-length product. Mean effective radiation dose for 120 kV and 75 mAs protocol (control group) was 0.29 ± 0.04 mSv; for 135 kV and 5 mAs protocol (study group A), this value was 0.02 ± 0. 003 mSv; and for 80 kV and 5 mAs protocol (study group B), this value was 0.005 ± 0. 0009 mSv. Mean effective radiation doses of study group A and B were significantly lower than the control group (P < 0.001). Study group A and control group images showed no significant difference in image quality except for some anatomic landmarks. Study group B images had lower image quality than control group images. Temporal bone CT with 135 kVp and 5 mAs can be performed at very low radiation exposure while maintaining high image quality.