Karen Joos

Karen Joos

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
HYHaoran Yu
Haoran Yu
JSJin-Hui Shen
Jin-Hui Shen
RSRohan J. Shah
Rohan J. Shah
NSNabil Simaan
Nabil Simaan
KJKaren Joos
Karen Joos
Real-time intraocular optical coherence tomography (OCT) visualization of tissues with surgical feedback can enhance retinal surgery. An intraocular 23-gauge B-mode forward-imaging co-planar OCT-forceps, coupling connectors and algorithms were developed to form a unique ophthalmic surgical robotic system. Approach to the surface of a phantom or goat retina by a manual or robotic-controlled forceps, with and without real-time OCT guidance, was performed. Efficiency of lifting phantom membranes was examined. Placing the co-planar OCT imaging probe internal to the surgical tool reduced instrument shadowing and permitted constant tracking. Robotic assistance together with real-time OCT feedback improved depth perception accuracy. The first-generation integrated OCT-forceps was capable of peeling membrane phantoms despite smooth tips.

16 July 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
KJKaren Joos
Karen Joos
JSJin-Hui Shen
Jin-Hui Shen
Optical coherence tomography (OCT) has a tremendous global impact upon the ability to diagnose, treat, and monitor eye diseases. A miniature 25-gauge forward-imaging OCT probe with a disposable tip was developed for real-time intraoperative ocular imaging of posterior pole and peripheral structures to improve vitreoretinal surgery. The scanning range was 2 mm when the probe tip was held 3-4 mm from the tissue surface. The axial resolution was 4-6 µm and the lateral resolution was 25-35 µm. The probe was used to image cellophane tape and multiple ocular structures.

1 December 2010 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
KJKaren Joos
Karen Joos
CLChun Li
Chun Li
RSRebecca Sappington
Rebecca Sappington
Purpose.: Intraocular pressure (IOP) fluctuations may occur in patients with glaucoma, but how these fluctuations affect axonal populations in the optic nerve and other structures in the eye has been difficult to assess. This study developed a rat model to evaluate the effect of intermittent controlled elevations in IOP on the morphology of the rat optic nerve. Methods.: IOP was transiently elevated for 1 hour on each of 6 days a week over 6 weeks with an adjustable vascular loop around the right topically anesthetized eye of Sprague-Dawley rats. IOP was measured by pneumatonometer before, immediately after, and at the end of 1 hour of treatment with ligature. Globes and optic nerve segments were prepared for histology and morphometry. Results.: Mean baseline IOP of 14.9 ± 1.8 mm Hg increased to 35.3 ± 2.6 mm Hg (P < 0.001) during 1-hour treatments and returned to 15.0 ± 2.2 mm Hg (P = 0.84) 1 hour after completion. The contralateral untreated eyes had a mean IOP of 14.2 ± 1.9 mm Hg at baseline and 14.6 ± 1.9 mm Hg at the end of treatment. Nerve fiber layer thinning (22%–25%) corresponded with a decrease (7%–10%) in soma number in the ganglion cell layer. Optic nerves displayed axonal degeneration with a modest axon loss of 6% and increased expression of glial acidic fibrillary protein in astrocytes. Conclusions.: Controlled daily 1-hour IOP elevations can be performed with an adjustable vascular loop in rats. After only 6 weeks, intermittent elevations in IOP produce changes in optic nerve consistent with early degeneration reported in chronic models of glaucoma.

3 April 2021 in Advances in Therapy
Verified
Journal Article
Open access
PDF file
EAElan Z. Ahronovich
Elan Z. Ahronovich
NSNabil Simaan
Nabil Simaan
KJKaren Joos
Karen Joos
The introduction of the intraocular vitrectomy instrument by Machemer et al. has led to remarkable advancements in vitreoretinal surgery enabling the limitations of human physiologic capabilities to be reached. To overcome the barriers of perception, tremor, and dexterity, robotic technologies have been investigated with current advancements nearing the feasibility for clinical use. There are four categories of robotic systems that have emerged through the research: (1) handheld instruments with intrinsic robotic assistance, (2) hand-on-hand robotic systems, (3) teleoperated robotic systems, and (4) magnetic guidance robots. This review covers the improvements and the remaining needs for safe, cost-effective clinical deployment of robotic systems in vitreoretinal surgery.

9 December 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
GGGiuseppe Del Giudice
Giuseppe Del Giudice
AOAndrew L. Orekhov
Andrew L. Orekhov
JSJin-Hui Shen
Jin-Hui Shen
KJKaren Joos
Karen Joos
NSNabil Simaan
Nabil Simaan
Continuum robots (CR) have been recently shown capable of micron-scale motion resolutions. Such motions are achieved through equilibrium modulation using indirect actuation for altering either internal preload forces or changing the cross-sectional stiffness along the length of a continuum robot. Previously reported, but unexplained, turning point behavior is modeled using two approaches. An energy minimization approach is first used to explain the source of this behavior. Subsequently, a kinematic model using internal constraints in multi-backbone CRs is used to replicate this turning point behavior. An approach for modeling the micro-motion differential kinematics is presented using experimental data based on the solution of a system of linear matrix equations. This approach provides a closed-form approximation of the empirical micro- motion kinematics and could be easily used for real-time control. A motivating application of image-based biopsy using 3D optical coherence tomography (OCT) is envisioned and demonstrated in this paper. A system integration for generating OCT volumes by sweeping a custom B-mode OCT probe is presented. Results showing high accuracy in obtaining 3D OCT measurements are shown using a commercial OCT probe. Qualitative results using a miniature probe integrated within the robot are also shown. Finally, closed-loop visual servoing using OCT data is demonstrated for guiding a needle into an agar channel. Results of this paper present what we believe is the first embodiment of a continuum robot capable of micro and macro motion control for 3D OCT imaging. This approach can support the development of new technologies for CRs capable of surgical intervention and micro-motion for ultra-precision tasks.

9 April 2014 in BMC Pediatrics
Verified
Journal Article
Open access
PDF file
YRYuna Rapoport
Yuna Rapoport
NBNancy Benegas
Nancy Benegas
RKRachel W Kuchtey
Rachel W Kuchtey
KJKaren Joos
Karen Joos
A case is reported of acute bilateral myopia and angle closure glaucoma in a 7-year-old patient from topiramate toxicity. This is the second known reported case of topiramate induced acute angle closure glaucoma and third known reported case of topiramate induced acute myopia in a pediatric patient.