Egemen KAYMAZ

Dr. Egemen KAYMAZ

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2022 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Open access
EKEgemen KAYMAZ
Egemen KAYMAZ
BMBanu Manav
Banu Manav
This study assesses residential areas which have been converted into workplaces and are still used after the Covid-19 in terms of visual, non-visual, and energy performance requirements of lighting. We proposed a lighting design using LED systems with dimmable and tuneable features. Circadian factors in WELL Building Standard are analyzed for compatibility with the current visual requirements for indoor workplaces and residential areas. The impact of various design parameters on lighting energy consumption, including daylight availability, occupancy-based lighting schedules, lighting control strategies, and light reflectance value of walls is evaluated through a case study in Turkey. Although the annual lighting energy consumption is higher than it was before the pandemic, building energy simulation results show that the application of LED systems with lighting energy measures can improve lighting energy performance by up to 38%. From the non-visual dimension of light, our data indicates that higher melanopic illuminance and/or colour temperature of light sources are necessary to entrain and sustain the circadian rhythm under overcast sky conditions in winter months. On the other hand, an increase in luminous intensity can lead to glare and higher energy consumption while a higher colour temperature may affect the physiology and psychology of occupants negatively.

28 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
EKEgemen KAYMAZ
Egemen KAYMAZ
BMBanu Manav
Banu Manav
This research proposes an integrated lighting and solar shading strategy to improve energy efficiency and user comfort in a retrofit project in a temperate-humid climate. The study examines a future library addition to an existing faculty building in Bursa, featuring highly glazed façades (77% southwest, 81% northeast window-to-wall ratio), an open-plan layout, and situated within an unobstructed low-rise campus environment. Trade-offs between daylight availability, heating, cooling, lighting energy use, and visual and thermal comfort are evaluated through integrated lighting (DIALux Evo), climate-based daylight (CBDM), and energy simulations (DesignBuilder, EnergyPlus, Radiance). Fifteen solar shading configurations—including brise soleil, overhangs, side fins, egg crates, and louvres—are evaluated alongside a daylight-responsive LED lighting system that meets BS EN 12464-1:2021. Compared to the reference case’s unshaded glazing, optimal design significantly improves building performance: a brise soleil with 0.4 m slats at 30° reduces annual primary energy use by 28.3% and operational carbon emissions by 29.1% and maintains thermal comfort per ASHRAE 55:2023 Category II (±0.7 PMV; PPD < 15%). Daylight performance achieves 91.5% UDI and 2.1% aSE, with integrated photovoltaics offsetting 129.7 kWh/m2 of grid energy. This integrated strategy elevates the building’s energy class under national benchmarks while addressing glare and overheating in the original design.

26 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
EKEgemen KAYMAZ
Egemen KAYMAZ
This study integrates in-situ Quantitative Infrared Thermography (QIRT) and Building Energy Simulation (BES) to optimize the energy performance of an existing multi-story residential building in a temperate climate. QIRT was utilized to diagnose thermal anomalies at the interfaces of uninsulated walls, RC skeleton and fenestration junctions, revealing significant thermal bridging and air infiltration while enabling the calculation of the Temperature Index (TI) at critical interfaces. A key finding of the non-destructive diagnostic phase was the discrepancy between in-situ (UINSITU) and theoretical (UCALC) thermal transmittance values, providing an empirical baseline for subsequent optimi-zations. A multi-objective analysis was conducted using genetic algorithms to evaluate 192 retrofit combinations, involving three insulation materials at four thicknesses and 16 glazing types. The impacts on primary energy consumption, CO₂ emissions, and 30-year global costs (per EN 15459-1:2017) were quantified under the volatile economic conditions. Findings indicate that the energy-optimal solution reduces primary energy by 53% and CO₂ emissions by 51%, while the cost-optimal configuration reduces global costs by 52% relative to the reference case. The Pareto analysis reveals a robust convergence between financial and energy efficiency targets, proving that deep retrofitting is an economically imperative strategy for achieving national decarbonization goals and the 2053 net-zero vision.


1 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
EKEgemen KAYMAZ
Egemen KAYMAZ
This study integrates in situ Quantitative Infrared Thermography (QIRT) and Building Energy Simulation (BES) to optimize the energy performance of an existing multi-story residential building in Istanbul, Türkiye. QIRT was utilized to diagnose thermal anomalies at the interfaces of uninsulated walls, the RC skeleton and fenestration junctions, revealing significant thermal bridging and air infiltration while enabling the calculation of the Temperature Index (TI) at critical interfaces. A key finding of the non-destructive diagnostic phase was the discrepancy between in situ (UINSITU) and theoretical (UCALC) thermal transmittance values, providing an empirical baseline for subsequent optimization. A multi-objective analysis, employing genetic algorithms (GAs), was conducted to evaluate 192 retrofit combinations, involving three insulation materials at four thicknesses and 16 glazing types. The impacts on primary energy consumption, CO2 emissions, and 30-year global costs (per EN 15459-1:2017) were quantified under volatile economic conditions. Findings indicate that the energy-optimal solution reduces primary energy by 53% and CO2 emissions by 51%, while the cost-optimal configuration reduces global costs by 52% relative to the reference case. The Pareto analysis reveals a robust convergence between financial and energy efficiency targets, proving that deep retrofitting is an economically imperative strategy for achieving national decarbonization goals and the 2053 net-zero vision.

29 December 2023
Verified
Conference Paper
Closed access
EKEgemen KAYMAZ
Egemen KAYMAZ
BMBanu Manav
Banu Manav
The study represents an approach to improving the annual lighting and primary energy performance of a residential building in temperate-humid and hot-dry Mediterranean climates in Turkey by simulation-based optimization method. In this context, five design variables and sixty four options including façade orientation, window size and configuration, window-to-wall ratio, thermo-physical properties of glazing, and light reflectance value of walls are investigated. The global cost of interior lighting system proposal and passive design strategies are calculated accordingly. Compared to the reference building, we achieved 26.5 - 27.6 % savings in lighting energy, 8.5 - 8.9 % in global costs and 10.5 - 12.4 % in primary energy as well as 9.4 - 10.6 % reduction in carbon emissions for the optimal solutions depending on the climate zone, respectively. Daylight performance of sample living rooms is also evaluated with climate-based daylight modelling (CBDM) metrics for the base case and optimal solutions.