Hiroyuki Kameda

Dr. Hiroyuki Kameda

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DKDaisuke Kato
Daisuke Kato
HKHiroyuki Kameda
Hiroyuki Kameda
NKNaoya Kinota
Naoya Kinota
TFTakaaki Fujii
Takaaki Fujii
BXBai Xiawei
Bai Xiawei
KKKohsuke Kudo
Kohsuke Kudo
The aquaporin-4 (AQP4) water channel is essential in neurofluid dynamics. AQP4 loss impairs solute exchange between the cerebrospinal fluid (CSF) and interstitial fluid (ISF). However, whether AQP4 expression affects solute clearance from the CSF space to the extracranial space remains unclear. This study aimed to investigate this using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) following the intrathecal administration of gadolinium-based contrast agents (GBCAs) to AQP4 knockout (KO) rats. AQP4 KO rats showed reduced efflux of intrathecal GBCAs to the extracranial spaces through CSF drainage pathways and increased retention of intrathecal GBCAs in the CSF space compared with the controls. These results suggest that AQP4 loss impairs solute clearance from the CSF space to the extracranial spaces via the CSF drainage pathways. This study revealed a close relationship between AQP4 expression and CSF solute clearance, contributing to a better understanding of the function of AQP4 in neurofluid dynamics.

15 September 2023 in Investigative Radiology
Verified
Journal Article
Open access
HKHiroyuki Kameda
Hiroyuki Kameda
NKNaoya Kinota
Naoya Kinota
DKDaisuke Kato
Daisuke Kato
TFTakaaki Fujii
Takaaki Fujii
THTaisuke Harada
Taisuke Harada
KKKohsuke Kudo
Kohsuke Kudo
Magnetic resonance imaging (MRI) is a crucial imaging technique for visualizing water in living organisms. Besides proton MRI, which is widely available and enables direct visualization of intrinsic water distribution and dynamics in various environments, MR-WTI (MR water tracer imaging) using 17O-labeled water has been developed, benefiting from the many advancements in MRI software and hardware that have substantially improved the signal-to-noise ratio and made possible faster imaging. This cutting-edge technique allows the generation of novel and valuable images for clinical use. This review elucidates the studies related to MRI water tracer techniques centered around 17O-labeled water, explaining the fundamental principles of imaging and providing clinical application examples. Anticipating continued progress in studies involving isotope-labeled water, this review is expected to contribute to elucidating the pathophysiology of various diseases related to water dynamics abnormalities and establishing novel imaging diagnostic methods for associated diseases.

1 January 2024 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
NKNaoya Kinota
Naoya Kinota
HKHiroyuki Kameda
Hiroyuki Kameda
BXBai Xiawei
Bai Xiawei
TFTakaaki Fujii
Takaaki Fujii
DKDaisuke Kato
Daisuke Kato
KKKohsuke Kudo
Kohsuke Kudo
Purpose: To investigate whether deep cervical lymph node (DCLN) ligation alters intracranial cerebrospinal fluid (CSF) tracer dynamics and outflow using a rat model with intrathecal dynamic contrast-enhanced (DCE) MRI.Methods: Six bilateral DCLN-ligated and six sham-operated rats were subjected to DCE MRI with Gd-BTDO3A, and dynamic T1-weighted images were acquired. ROIs were collected from the CSF at the C1 level (CSF_C1), CSF between the olfactory bulbs (CSF_OB), CSF at the pituitary recess (CSF_PitR), and CSF at the pineal recess (CSF_PinR), upper nasal turbinate (UNT), olfactory bulbs, cerebrum, and the jugular region. Time-intensity curves were evaluated, and the maximum slope, peak timing, peak signal ratio, and elimination half-life for the four CSF ROIs and UNT were calculated and compared.Results: Delayed tracer arrival in the rostral CSF space and the nasal cavity with tracer retention in the ventral CSF space were observed in the ligation group. The maximum slopes were smaller in the ligation group at UNT (sham: 0.075 ± 0.0061, ligation: 0.044 ± 0.0086/min, P = 0.011). A significant difference was not detected in peak timings. The peak signal ratio values were lower in the ligation group at UNT (sham: 2.12 ± 0.19, ligation: 1.72 ± 0.11, P = 0.011). The elimination half-life was delayed in the ligation group at CSF_C1 (sham: 30.5 ± 2.70, ligation: 44.4 ± 12.6 min, P = 0.043), CSF_OB (sham: 30.2 ± 2.67, ligation: 44.8 ± 7.47 min, P = 0.021), and CSF_PitR (sham: 30.2 ± 2.49, ligation: 41.3 ± 7.57 min, P = 0.021).Conclusion: The DCLN ligation in rats blocked CSF outflow into the nasal cavity and caused CSF retention.

1 April 2022 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
HKHiroyuki Kameda
Hiroyuki Kameda
THTaisuke Harada
Taisuke Harada
KIKinya Ishizaka
Kinya Ishizaka
MKMasayoshi Kajiyama
Masayoshi Kajiyama
KKKohsuke Kudo
Kohsuke Kudo