Background: The early detection of type 1 diabetes (T1D) through screening for major islet autoantibodies is receiving increasing attention as a public health strategy, exemplified by the recent implementation of a pilot pediatric screening program in Italy. The transition from research-based screening to large-scale population initiatives needs automated and standardized assays that are capable of processing extensive sample volumes. Hence, this study aimed to evaluate the analytical performance and comparability of a fully automated chemiluminescence immunoassay (CLIA) compared to a conventional enzyme-linked immunosorbent assay (ELISA) for the detection of three classes of major islet antibodies—anti-GAD (GADA), anti-IA-2 (IA-2A), and anti-ZnT8 (ZnT8A). Methods: A total of 104 serum specimens were analyzed for each autoantibody using both ELISA (RSR and Medyzim, DYNES, DSX) and CLIA (MAGLUMI 800). Assay precision and linearity were assessed through intra-assay variability studies and dilution protocols. Methods agreement was evaluated with Passing–Bablok regression, Spearman’s correlation, Bland–Altman analysis, and Cohen’s kappa statistics. Results: The CLIA showed good precision and excellent linearity across clinically relevant concentration ranges of all islet antibodies. Correlation coefficients and categorical agreement between CLIA and ELISA were high (r > 0.96 and Cohen’s kappa >0.8 for all), with ZnT8A exhibiting the highest concordance. However, proportional biases were found, as CLIA systematically underestimated GADA and ZnT8A levels, while overestimated IA-2A compared to the ELISA. Conclusions: The CLIA displayed satisfactory precision and agreement with ELISA for GADA, IA-2A, and ZnT8A detection. Our findings support the use of these automated immunoassays in large-scale population initiatives for diagnosing T1D, but we also highlight the need for further efforts to achieve better inter-assay harmonization.
Background: Early detection of type 1 diabetes (T1D) through major islet antibodies screening is gaining momentum as public health strategy, with Italy recently implementing a pilot pediatric screening program. The transition from research-based screening to large-scale population initiatives needs automated and standardized assays capable of processing extensive sample volumes. This study was hence aimed at evaluating the analytical performance and comparability of a fully-automated chemiluminescence immunoassay (CLIA) compared to a conventional enzyme-linked immunosorbent assay (ELISA) for detection of three classes of major islet antibodies anti-GAD (GADA), anti-IA-2 (IA-2A) and anti-ZnT8 (ZnT8A). Methods: A total of 104 serum specimens were analyzed for each autoantibody using both ELISA (DYNES, DSX) and CLIA (MAGLUMI 800). Assay precision and linearity were assessed through intra-assay variability studies and dilution protocols. Methods agreement was evaluated with Passing-Bablok regression, Spearman’s correlation, Bland-Altman analysis and Cohen’s kappa statistics. Results: CLIA showed good precision and excellent linearity across clinically relevant concentration ranges of all islet antibodies. Correlation coefficients and categorical agreement between CLIA and ELISA were high (r>0.96 and Cohen’s kappa >0.8 for all), with ZnT8A exhibiting the highest concordance. However, proportional biases were found, as CLIA systematically underestimated GADA and ZnT8A levels, while overestimated IA-2A compared with ELISA. Conclusions: CLIA assays displayed satisfactory precision and agreement with ELISA for GADA, IA-2A and ZnT8A detection. Our findings support the use of these automated immunoassay in large-scale population initiatives for diagnosing TD1, but we also highlight the need for further efforts to achieve better inter-assay harmonization.
Background: Circulating bile acid (BA) profiles are increasingly explored in pancreatic cancer, although their interpretation is often complicated by biliary obstruction and its clinical management. In this study, we characterized plasma BA profiles in pancreatic ductal adenocarcinoma (PDAC) and assessed the relative contributions of tumor localization, histological subtype, cholestasis, and cholestasis-related interventions. Methods: Plasma BAs were quantified by LC-MS/MS in patients with PDAC of the pancreatic head (hPDAC, n = 132), PDAC of the body-tail (tPDAC, n = 42), and non-PDAC tumors of the pancreatic head (hnonPDAC, n = 34). BA concentrations and derived ratios were log-transformed and standardized, and their associations with bilirubin were examined using multivariable linear models, LOESS, and multivariate longitudinal analyses. Results: UDCA therapy was associated with markedly increased circulating UDCA, higher total BA concentrations, and enrichment of secondary BA species. Direct bilirubin explained more variability in BA composition than binary jaundice classification and showed a non-linear association with BA remodeling, with a distinct metabolic profile emerging only at high bilirubin levels. Longitudinally, BA profiles changed substantially over time in hPDAC, largely in parallel with bilirubin, whereas they remained comparatively stable in tPDAC. After adjustment for bilirubin, tumor-related differences were modest and context-dependent. Conclusions: Overall, circulating BA profiles in pancreatic cancer appear to be driven predominantly by cholestasis and its management rather than by tumor-related features alone.