Stephen D Klyce

Dr. Stephen D Klyce

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2001 in Archives of Ophthalmology (1950)
Verified
Journal Article
Open access
PDF file
MEMichael J. Endl
Michael J. Endl
CMCarlos E. Martinez
Carlos E. Martinez
SKStephen D Klyce
Stephen D Klyce
MMMarguerite B. McDonald
Marguerite B. McDonald
SCSteven J. Coorpender
Steven J. Coorpender
HHHoward C. Howland
Howard C. Howland
REFRACTIVE surgical procedures attempt to improve unaided visual acuity and correct spherocylindrical errors by reshaping the central cornea. In myopic subjects, the curvature is reduced, whereas hyperopic subjects require an increase in the central curvature.

1 March 2007 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JTJuan Tabernero
Juan Tabernero
SKStephen D Klyce
Stephen D Klyce
ESEdwin J. Sarver
Edwin J. Sarver
PAPablo Artal
Pablo Artal
Purpose. When keratorefractive surgery is used to treat a central corneal diameter smaller than the resting pupil, visual symptoms of polyopia, ghosting, blur, haloes, and glare can be experienced. Progress has been made to enlarge the area of surgical treatment to extend beyond the photopic pupil; however, geometric limitations can pose restrictions to extend the treatment beyond the mesopic pupil diameter and can lead to impediments in night vision. The size of the treated area that has achieved good optical performance has been defined as the functional optical zone (FOZ). In this study the authors developed three objective methods to measure the FOZ. methods. Corneal topography examination results from 1 eye of 34 unoperated normal eyes and 32 myopic eyes corrected by laser in situ keratomileusis (LASIK) were evaluated in three ways. First, a uniform axial power method (FOZA) assessed the area of the postoperative cornea that was within a ±0.5-D window centered on the mathematical mode. Second, FOZ was determined based on the corneal wavefront true RMS error as a function of the simulated pupil size (FOZR). Third, FOZ was determined from the radial MTF, established at the retinal plane as a function of pupil size (FOZM). results. Means for each of the FOZ methods (FOZA, FOZR, and FOZM) were 7.6, 9.1, and 7.7 mm, respectively, for normal eyes. For LASIK-corrected eyes, these means were 6.0, 6.9, and 6.0 mm. Overall, an average decrease of 1.8 mm in the functional optical zone was found after the LASIK procedure. Correlations between the FOZ methods after LASIK showed acceptable and statistically significant values (R = 0.71, 0.70, and 0.61; P < 0.01). conclusions. These methods will be useful to more fully characterize corneal treatment profiles after keratorefractive surgery. Because of its ease of implementation, direct spatial correspondence to corneal topography, and good correlation to the other more computationally intensive methods, the semiempiric uniform axial power method (FOZA) appears to be most practical in use. The ability to measure the size of the FOZ should permit further evolution of keratorefractive surgical lasers and their algorithms to reduce the night vision impediments that can arise from functional optical zones that do not encompass the entire mesopic pupil.

3 September 2004 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
SKStephen D Klyce
Stephen D Klyce
MKMichael D Karon
Michael D Karon
MSMichael K Smolek
Michael K Smolek
PURPOSE: Zernike expansion has been selected for use in describing wavefront aberrations in the human eye. The advantages and limitations of this approach are assessed for eyes with varying degrees of aberration.METHODS: Corneal topography examinations were taken with the Nidek OPD-Scan topographer/aberrometer. These higher data density corneal topography examinations were converted to height data and subsequently to wavefront representations. System noise was evaluated with a 2D frequency analysis of 43-D test balls. Both Zernike polynomials and 2D Fourier transforms were used to evaluate fidelity in the presentation of the point spread function. A display format for potential clinical use was developed based upon Zernike decomposition.RESULTS: Systematic noise from the corneal topographer was found to be minimal and, when eliminated, produced small changes in the point spread function. Using Zernike decomposition up to the 30th order failed to preserve the higher frequency aberrations present in aberrated eyes. Use of a Zernike decomposition display with a fixed micron scale presented only clinically significant details of spherical aberration, coma, trefoil, irregular components above third order and total higher-order aberrations (above second order).CONCLUSIONS: Zernike polynomials excel in extracting the low-order optical characteristics of visual optics. Zernikes accurately represent both low- and high-order aberrations in normal eyes where high-order aberrations are clinically insignificant. For eyes after corneal surgery or eyes with corneal pathology such as keratoconus that have significant higher-order aberrations, the Zernike method fails to capture all clinically significant higher-order aberrations. [J Refract Surg 2004;20:S537-S541]

1 September 2020 in Experimental Eye Research
Verified
Journal Article
Closed access
SKStephen D Klyce
Stephen D Klyce

2 September 2005 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
SKStephen D Klyce
Stephen D Klyce
MKMichael D Karon
Michael D Karon
MSMichael K Smolek
Michael K Smolek
PURPOSE: To present a corneal topography screening device for the detection of corneal ectasias and various refractive procedures based on corneal topography patterns. METHODS: A database of corneal topography patterns were analyzed and used to "train" a neural network on nine different corneal topography patterns using nineteen corneal topography indices of corneal shape and power. RESULTS: Sample normal and corneal topographies were recognized correctly. CONCLUSIONS: The use of the corneal navigator to screen various corneal topographies aids clinical diagnosis. [J Refract Surg. 2005;21(Suppl):S617-S622.]

1 December 2018 in Ophthalmology
Verified
Journal Article
Closed access
SKStephen D Klyce
Stephen D Klyce