Lukas Rier

Dr. Lukas Rier

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2023 in NeuroImage
Verified
Journal Article
Open access
NHNiall Holmes
Niall Holmes
MRMolly Rea
Molly Rea
RHRyan M. Hill
Ryan M. Hill
JLJames Leggett
James Leggett
LELucy J. Edwards
Lucy J. Edwards
RBRichard Bowtell
Richard Bowtell
The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.

12 March 2023 in NeuroImage
Verified
Journal Article
Open access
NRNatalie Rhodes
Natalie Rhodes
MRMolly Rea
Molly Rea
EBElena Boto
Elena Boto
LRLukas Rier
Lukas Rier
VSVishal Shah
Vishal Shah
MBMatthew J. Brookes
Matthew J. Brookes
Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.

1 January 2021 in NeuroImage: Clinical
Verified
Journal Article
Open access
CAChristopher M. Allen
Christopher M. Allen
LHLloyd Halsey
Lloyd Halsey
GTGogem Topcu
Gogem Topcu
LRLukas Rier
Lukas Rier
LGLauren E. Gascoyne
Lauren E. Gascoyne
NENikos Evangelou
Nikos Evangelou
The global incidence of traumatic brain injuries is rising, with at least 80% being classified as mild. These mild injuries are not visible on routine clinical imaging. The potential clinical role of a specific imaging biomarker be it diagnostic, prognostic or directing and monitoring progress of personalised treatment and rehabilitation has driven the exploration of several new neuroimaging modalities. This systematic review examined the evidence for magnetoencephalography (MEG) to provide an imaging biomarker in mild traumatic brain injury (mTBI). Our review was prospectively registered on PROSPERO: CRD42019151387. We searched EMBASE, MEDLINE, trial registers, PsycINFO, Cochrane Library and conference abstracts and identified 37 papers describing MEG changes in mTBI eligible for inclusion. Since meta-analysis was not possible, based on the heterogeneity of reported outcomes, we provide a narrative synthesis of results. The two most promising MEG biomarkers are excess resting state low frequency power, and widespread connectivity changes in all frequency bands. These may represent biomarkers with potential for diagnostic application, which reflect time sensitive changes, or may be capable of offering clinically relevant prognostic information. In addition, the rich data that MEG produces are well-suited to new methods of machine learning analysis, which is now being actively explored. MEG reveals several promising biomarkers, in the absence of structural abnormalities demonstrable with either computerised tomography or magnetic resonance imaging. This review has not identified sufficient evidence to support routine clinical use of MEG in mTBI currently. However, verifying MEG's potential would help meet an urgent clinical need within civilian, sports and military medicine.

9 October 2023 in Imaging Neuroscience
Verified
Journal Article
Open access
PDF file
LRLukas Rier
Lukas Rier
SMSebastian Michelmann
Sebastian Michelmann
HRHarrison Ritz
Harrison Ritz
VSVishal Shah
Vishal Shah
RHRyan M. Hill
Ryan M. Hill
EBElena Boto
Elena Boto
Magnetoencephalography with optically pumped magnetometers (OPM-MEG) offers a new way to record electrophysiological brain function, with significant advantages over conventional MEG, including adaptability to head shape/size, free movement during scanning, increased signal amplitude, and no reliance on cryogenics. However, OPM-MEG remains in its infancy, with significant questions to be answered regarding the optimal system design. Here, we present an open-source dataset acquired using a newly constructed OPM-MEG system with a triaxial sensor design, 168 channels, OPM-optimised magnetic shielding, and active background field control. We measure the test-retest reliability of the human connectome, which was computed using amplitude envelope correlation to measure whole-brain (parcellated) functional connectivity, in 10 individuals while they watch a 600 s move clip. Our results show high repeatability between experimental runs at the group level, with a correlation coefficient of 0.81 in the θ, 0.93 in α, and 0.94 in β frequency ranges. At the individual subject level, we found marked differences between individuals, but high within-subject robustness (correlations of 0.56 ± 0.25, 0.72 ± 0.15, and 0.78 ± 0.13 in α, θ, and β respectively). These results compare well to previous findings using conventional MEG and show that OPM-MEG is a viable way to robustly characterise connectivity.

20 September 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
NHNiall Holmes
Niall Holmes
JLJames Leggett
James Leggett
RHRyan M. Hill
Ryan M. Hill
LRLukas Rier
Lukas Rier
EBElena Boto
Elena Boto
RBRichard Bowtell
Richard Bowtell
Wearable magnetoencephalography based on optically pumped magnetometers (OPM-MEG) offers non-invasive and high-fidelity measurement of human brain electrophysiology. The flexibility of OPM-MEG also means it can be deployed in participants of all ages and permits scanning during movement. However, the magnetic fields generated by neuronal currents – which form the basis of the OPM-MEG signal – are much smaller than environmental fields, and this means measurements are highly sensitive to interference. Further, OPMs have a low dynamic range, and should be operated in near-zero background field. Scanners must therefore be housed in specialised magnetically shielded rooms (MSRs), formed from multiple layers of shielding material. The MSR is a critical component, and current OPM-optimised shields are large (>3 m in height), heavy (>10,000 kg) and expensive (with up to 5 layers of material). This restricts the uptake of OPM-MEG technology. Here, we show that the application of the Maxwell filtering techniques signal space separation (SSS) and its spatiotemporal extension (tSSS) to OPM-MEG data can isolate small signals of interest measured in the presence of large interference. We compare phantom recordings and MEG data from a participant performing a motor task in a state-of-the-art 5-layer MSR, to similar data collected in a lightly shielded room: application of tSSS to data recorded in the lightly shielded room allowed accurate localisation of a dipole source in the phantom and neuronal sources in the brain. Our results point to future deployment of OPM-MEG in lighter, cheaper and easier-to-site MSRs which could catalyse widespread adoption of the technology.

22 May 2025 in Imaging Neuroscience
Verified
Journal Article
Open access
NRNatalie Rhodes
Natalie Rhodes
LRLukas Rier
Lukas Rier
EBElena Boto
Elena Boto
RHRyan M. Hill
Ryan M. Hill
MBMatthew J. Brookes
Matthew J. Brookes
Source modelling in magnetoencephalography (MEG) infers the spatial origins of electrophysiological signals in the brain. Typically, this requires an anatomical MRI scan of the subject’s head, from which models of the magnetic fields generated by the brain (the forward model) are derived. Wearable MEG—based on optically pumped magnetometers (OPMs)—enables MEG measurement from participants who struggle to cope with conventional scanning environments (e.g., children), enabling study of novel cohorts. However, its value is limited if an MRI scan is still required for source modelling. Here we describe a method of warping template MRIs to 3D structured-light scans of the head, to generate “pseudo-MRIs”. We apply our method to data from 20 participants during a sensory task, measuring induced (beta band) responses and whole-brain functional connectivity. Results show that the group average locations of peak task-induced beta modulation were separated by 2.75 mm, when comparing real- and pseudo-MRI approaches. Group averaged time–frequency spectra were also highly correlated (Pearson correlation 0.99) as were functional connectome matrices (0.87) and global connectivity (0.98). In sum, our results demonstrate that source-localised OPM-MEG data, modelled with and without an individual MRI scan, can be comparable. While individual MRI scans remain the “gold standard” for OPM-MEG modelling, our method will be useful for future studies where MRI data capture is challenging.