Tamaki Takano

Dr. Tamaki Takano


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2011 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
TTTamaki Takano
Tamaki Takano
YOYoshinori Ohtsu
Yoshinori Ohtsu
TTTakamitsu Terasaki
Takamitsu Terasaki
YWYuko Wada
Yuko Wada
JAJun Amano
Jun Amano
Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal of the infected prosthesis and an appropriate course of antibiotics were attributed to good clinical outcomes in our cases.

1 May 2014 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
KKKazunori Komatsu
Kazunori Komatsu
TTTamaki Takano
Tamaki Takano
TTTakamitsu Terasaki
Takamitsu Terasaki
YWYuko Wada
Yuko Wada
TSTatsuichiro Seto
Tatsuichiro Seto
JAJun Amano
Jun Amano

1 October 2000 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
SKShinji Kawahito
Shinji Kawahito
TTTamaki Takano
Tamaki Takano
KNKin‐Ichi Nakata
Kin‐Ichi Nakata
TMTomohiro Maeda
Tomohiro Maeda
KNKenji Nonaka
Kenji Nonaka
YNYukihiko Nosé
Yukihiko Nosé

1 July 2000 in ASAIO Journal
Verified
Journal Article
Open access
TMTomohiro Maeda
Tomohiro Maeda
AIAkinori Iwasaki
Akinori Iwasaki
SKShinji Kawahito
Shinji Kawahito
KNKin-Ichi Nakata
Kin-Ichi Nakata
KNKenji Nonaka
Kenji Nonaka
YNYukihiko Nosé
Yukihiko Nosé
A silicone membrane hollow fiber oxygenator applicable for use as an extracorporeal membrane oxygenator (ECMO) has been developed in our laboratory. This silicone hollow fiber displays astonishing mechanical stability, is barely compressible or stretchable, and assembles easily while maintaining good gas permeability. The priming volume is 140 cc with a surface area of 0.8 m2. This study evaluated the gas transfer performances and biocompatibility of the oxygenator under ECMO and CPB conditions. In vitro studies that were performed at a blood flow rate of 2 L/min, and revealed O2 and CO2 gas transfer rates of 82.35 ± 0.56 ml/m2/L/min and 38.72 ± 2.88 ml/m2/L/min, respectively. The commercially available Kolobow (Avecor 1500) oxygenator was used as the control, and had O2 and CO2 gas transfer rates of 53.8 ± 0.5 ml/m2/L/min and 24.7 ± 2.0 ml/m2/L/min. To evaluate blood trauma, Normalized Index of Hemolysis (NIH) was measured according to American Society of Testing and Materials (ASTM) standards. The NIH findings were 0.0112 g/100L at a blood flow of 1 L/min, and 0.0152 g/100L at 5 L/min. Three ex vivo experiments, using a blood flow rate of 1 L/min, were performed with venoarterial bypass, and O2 transfer rate and CO2 transfer rate of the oxygenators were well maintained. This indicates that this preclinical silicone membrane hollow fiber oxygenator has superior efficiency, less blood trauma, and is smaller when compared with the only clinically available Kolobow oxygenator.

9 April 2014 in Artificial Organs
Verified
Journal Article
Open access
PDF file
HKHiromu Kehara
Hiromu Kehara
TTTamaki Takano
Tamaki Takano
NONoburo Ohashi
Noburo Ohashi
TTTakamitsu Terasaki
Takamitsu Terasaki
JAJun Amano
Jun Amano
Blood trauma may be lower with centrifugal pumps (CPs) than with roller pumps (RPs) during cardiopulmonary bypass (CPB), because, unlike RPs, CPs do not compress the tubing, and shear stress is considered lower in CPs than in RPs. However, relative platelet function remains unclear. Using multiple electrode aggregometry (MEA), we compared platelet function with CP and RP. Ten swine underwent CPB for 3 h, with five weaned off using CP and five using RP. Platelet function was measured using MEA, as were hemoglobin concentration and platelet count, before sternotomy, after heparin infusion, 30 min and 3 h after starting CPB, after protamine infusion, and 60 min after stopping CPB. Platelet activation was initiated with adenosine diphosphate (ADP), arachidonic acid (AA), and thrombin receptor‐activating protein 6 (TRAP). Fibrinogen, platelet factor 4 (PF4), and β‐thromboglobin (β‐TG) concentrations were measured before sternotomy and 60 min after stopping CPB. In the CP group and using ADP, aggregation was significantly reduced 30 min (P = 0.019) and 3 h (P = 0.027) after starting CPB, recovering to baseline 60 min after CPB was stopped. In the RP group, aggregation was significantly decreased 30 min (P = 0.007) and 3 h (P = 0.003) after starting CPB and after protamine administration (P = 0.028). With AA, aggregation significantly decreased 30 min after starting CPB in both the CP (P = 0.012) and RP (P = 0.016) groups, slightly increasing 3 h after starting CPB and after protamine infusion, and recovering to baseline 60 min after CPB cessation. With TRAP, aggregation in the CP and RP groups decreased 30 min after starting the pump, although changes were not significant; aggregation gradually recovered after 3 h and returned to baseline 60 min after the pumps were stopped. There were no significant differences at all sampling points of MEA. In both groups, fibrinogen, PF4, and β‐TG concentrations were similar 60 min after pump cessation and before sternotomy. Platelet function, evaluated with MEA, was lowest 30 min after CPB was started but did not decrease over time in either group. As assessed by MEA, platelet function using CP and RP did not differ significantly. Platelet dysfunction was caused mainly by initial contact with foreign materials and may not be dependent on type of pump.

2 August 2016 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
MSMasayuki Sakaguchi
Masayuki Sakaguchi
TTTamaki Takano
Tamaki Takano
Hemolysis related to a kinked prosthetic graft or inner felt strip is a very rare complication after aortic surgery. We describe herein a case of hemolytic anemia that developed due to aortic flap of the dissection and inversion of an inner felt strip that was applied at the proximal anastomosis of a replaced ascending aorta 10 years previously. A 74-year-old woman presented with consistent hemolytic anemia 10 years after replacement of the ascending aorta to treat Stanford type A acute aortic dissection. The cause of hemolysis was attributed to mechanical injury of red blood cells at a site of stenosis caused by aortic flap of the dissection and inversion of the felt strip used for the proximal anastomosis. Repeated resection of the strip and graft replacement of the ascending aorta resolved this problem. We considered that blood flow disrupted by a jet of blood at the site of the proximal inner felt strip was the cause of severe hemolysis, we describe rare hemolytic anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta.