Jessica K. Zègre-Hemsey

Dr. Jessica K. Zègre-Hemsey

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BDBarbara J Drew
Barbara J Drew
PHPatricia Harris
Patricia Harris
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
TMTina Mammone
Tina Mammone
DSDaniel Schindler
Daniel Schindler
XHXiao Hu
Xiao Hu
Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing “alarm fatigue” which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO2, and respiration waveforms as well as user settings and alarms were stored on 461 adults treated in intensive care units. Using a well-defined alarm annotation protocol, nurse scientists with 95% inter-rater reliability annotated 12,671 arrhythmia alarms. A total of 2,558,760 unique alarms occurred in the 31-day study period: arrhythmia, 1,154,201; parameter, 612,927; technical, 791,632. There were 381,560 audible alarms for an audible alarm burden of 187/bed/day. 88.8% of the 12,671 annotated arrhythmia alarms were false positives. Conditions causing excessive alarms included inappropriate alarm settings, persistent atrial fibrillation, and non-actionable events such as PVC's and brief spikes in ST segments. Low amplitude QRS complexes in some, but not all available ECG leads caused undercounting and false arrhythmia alarms. Wide QRS complexes due to bundle branch block or ventricular pacemaker rhythm caused false alarms. 93% of the 168 true ventricular tachycardia alarms were not sustained long enough to warrant treatment. The excessive number of physiologic monitor alarms is a complex interplay of inappropriate user settings, patient conditions, and algorithm deficiencies. Device solutions should focus on use of all available ECG leads to identify non-artifact leads and leads with adequate QRS amplitude. Devices should provide prompts to aide in more appropriate tailoring of alarm settings to individual patients. Atrial fibrillation alarms should be limited to new onset and termination of the arrhythmia and delays for ST-segment and other parameter alarms should be configurable. Because computer devices are more reliable than humans, an opportunity exists to improve physiologic monitoring and reduce alarm fatigue.

29 June 2023 in Nature Medicine
Verified
Journal Article
Open access
PDF file
SASalah S. Al-Zaiti
Salah S. Al-Zaiti
CMChristian Martin-Gill
Christian Martin-Gill
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
ZBZeineb Bouzid
Zeineb Bouzid
ZFZiad Faramand
Ziad Faramand
CCClifton W. Callaway
Clifton W. Callaway
Patients with occlusion myocardial infarction (OMI) and no ST-elevation on presenting electrocardiogram (ECG) are increasing in numbers. These patients have a poor prognosis and would benefit from immediate reperfusion therapy, but, currently, there are no accurate tools to identify them during initial triage. Here we report, to our knowledge, the first observational cohort study to develop machine learning models for the ECG diagnosis of OMI. Using 7,313 consecutive patients from multiple clinical sites, we derived and externally validated an intelligent model that outperformed practicing clinicians and other widely used commercial interpretation systems, substantially boosting both precision and sensitivity. Our derived OMI risk score provided enhanced rule-in and rule-out accuracy relevant to routine care, and, when combined with the clinical judgment of trained emergency personnel, it helped correctly reclassify one in three patients with chest pain. ECG features driving our models were validated by clinical experts, providing plausible mechanistic links to myocardial injury.

1 November 2021 in Open Access Emergency Medicine
Verified
Journal Article
Open access
PDF file
AJAnna M Johnson
Anna M Johnson
CCChristopher J Cunningham
Christopher J Cunningham
EAEvan Arnold
Evan Arnold
WRWayne D Rosamond
Wayne D Rosamond
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
The use of unmanned aerial vehicles or “drones” has expanded in the last decade, as their technology has become more sophisticated, and costs have decreased. They are now used routinely in farming, environmental surveillance, public safety, commercial product delivery, recreation, and other applications. Health-related applications are only recently becoming more widely explored and accepted. The use of drone technology in emergency medicine is especially promising given the need for a rapid response to enhance patient outcomes. The purpose of this paper is to describe some of the main current and expanding applications of drone technology in emergency medicine and to describe challenges and future opportunities. Current applications being studied include delivery of defibrillators in response to out-of-hospital cardiac arrest, blood and blood products in response to trauma, and rescue medications. Drones are also being studied and actively used in emergency response to search and rescue operations as well as disaster and mass casualty events. Current challenges to expanding their use in emergency medicine and emergency medical system (EMS) include regulation, safety, flying conditions, concerns about privacy, consent, and confidentiality, and details surrounding the development, operation, and maintenance of a medical drone network. Future research is needed to better understand end user perceptions and acceptance. Continued technical advances are needed to increase payload capacities, increase flying distances, and integrate drone networks into existing 9-1-1 and EMS systems. Drones are a promising technology for improving patient survival, outcomes, and quality of life, particularly for those in areas that are remote or that lack funds or infrastructure. Their cost savings compared with ground transportation alone, speed, and convenience make them particularly applicable in the field of emergency medicine. Research to date suggests that use of drones in emergency medicine is feasible, will be accepted by the public, is cost-effective, and has broad application.

1 December 2020 in Resuscitation
Verified
Journal Article
Closed access
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
MGMary E. Grewe
Mary E. Grewe
AJAnna M. Johnson
Anna M. Johnson
EAEvan Arnold
Evan Arnold
CCChristopher J. Cunningham
Christopher J. Cunningham
WRWayne D. Rosamond
Wayne D. Rosamond

1 September 2016 in Journal of Electrocardiology
Verified
Journal Article
Closed access
JGJ. Lee Garvey
J. Lee Garvey
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
RGRichard Gregg
Richard Gregg
JSJonathan R. Studnek
Jonathan R. Studnek

3 September 2018 in Current Cardiovascular Risk Reports
Verified
Journal Article
Closed access
PDF file
JZJessica K. Zègre-Hemsey
Jessica K. Zègre-Hemsey
BBBrittany Bogle
Brittany Bogle
CCChristopher J. Cunningham
Christopher J. Cunningham
KSKyle Snyder
Kyle Snyder
WRWayne Rosamond
Wayne Rosamond