The transverse resolution of optical coherence tomography is decreased by aberrations introduced from optical components and the tested samples. In this paper, an automated fast computational aberration correction method based on a stochastic parallel gradient descent (SPGD) algorithm is proposed for aberration-corrected imaging without adopting extra adaptive optics hardware components. A virtual phase filter constructed through combination of Zernike polynomials is adopted to eliminate the wavefront aberration, and their coefficients are stochastically estimated in parallel through the optimization of the image metrics. The feasibility of the proposed method is validated by a simulated resolution target image, in which the introduced aberration wavefront is estimated accurately and with fast convergence. The computation time for the aberration correction of a 512 × 512 pixel image from 7 terms to 12 terms requires little change, from 2.13 s to 2.35 s. The proposed method is then applied for samples with different scattering properties including a particle-based phantom, ex-vivo rabbit adipose tissue, and in-vivo human retina photoreceptors, respectively. Results indicate that diffraction-limited optical performance is recovered, and the maximum intensity increased nearly 3-fold for out-of-focus plane in particle-based tissue phantom. The SPGD algorithm shows great potential for aberration correction and improved run-time performance compared to our previous Resilient backpropagation (Rprop) algorithm when correcting for complex wavefront distortions. The fast computational aberration correction suggests that after further optimization our method can be integrated for future applications in real-time clinical imaging.
A method for measuring the focal length of the lens by a Fizeau interferometer is proposed. Based on the Gaussian imaging equation and the longitudinal displacements of the object point and image point, a precise formula for focal length calculation is deduced. The longitudinal displacement of the object points is determined by the wavefront difference method with a subnanometer resolution. An experimental system for focal length measurements is set up to verify the principle. The sources of uncertainty in measurement are discussed. Both the positive and negative lens experimental results indicate that the measurement accuracy is less than 0.16% under normal experimental environment.
Metalens arrays hold great promise for compact light-field imaging systems owing to their compactness and wavefront shaping capabilities. However, their fixed focal lengths fundamentally limit depth-of-field modulation and axial scanning, restricting their adaptability to diverse light-field imaging scenarios. Here, we demonstrate adaptive light-field imaging using a varifocal Alvarez metalens array. The array is composed of two closely bonded metasurfaces, each patterned with 24 × 20 cubic-phase sub-regions. Through relative lateral displacement, the Alvarez metalens array achieves continuous focal length tuning from 3.33 mm to 4.50 mm. Integrated into a plenoptic imaging system, the proposed metalens array enables dynamic focusing and an expanded depth range. We further introduce a MultiLensFusion algorithm that combines these multi-focus captures into high-resolution, all-in-focus renderings. This work offers a compact and versatile platform for next-generation light-field imaging systems with dynamically tunable optical response.
Non-destructive and accurate characterization of high aspect ratio (HAR) and composite micro-trenches is critical for advanced microfabrication but remains a major challenge. Conventional coherence scanning interferometry (CSI), while widely adopted, suffers from low signal-to-noise ratio (SNR) and limited lateral resolution when applied to HAR and composite microstructures. Here, we present Fourier ptychographic coherence scanning interferometry (FP-CSI), the first transmissive CSI modality that integrates the aperture synthesis strategy of Fourier ptychographic microscopy with the quantitative phase-resolved capability of interferometry. FP-CSI enables robust three-dimensional morphology reconstruction with enhanced SNR and improved lateral resolution, without reliance on iterative phase retrieval. We demonstrate accurate measurements of a HAR micro-trench (300 μm depth, 30:1 aspect ratio) and micro-electro-mechanical system (MEMS) devices (aspect ratios 6:1–20:1). FP-CSI achieves lateral resolution up to the incoherent diffraction limit and maintains this performance even at trench bottoms. Owing to its fidelity, robustness, and non-destructive operation, FP-CSI provides a powerful new metrology platform for next-generation semiconductor inspection, precision manufacturing, and emerging micro-optoelectronic systems.