Florina Teodorescu

Dr. Florina Teodorescu

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
FCFereshteh Chekin
Fereshteh Chekin
FTFlorina Teodorescu
Florina Teodorescu
YCYannick Coffinier
Yannick Coffinier
GPGuo-Hui Pan
Guo-Hui Pan
ABAlexandre Barras
Alexandre Barras
SSSabine Szunerits
Sabine Szunerits

1 January 2017 in Journal of Controlled Release
Verified
Journal Article
Closed access
FTFlorina Teodorescu
Florina Teodorescu
YOYavuz Oz
Yavuz Oz
GQGurvan Quéniat
Gurvan Quéniat
AAAmar Abderrahmani
Amar Abderrahmani
CFCatherine Foulon
Catherine Foulon
SSSabine Szunerits
Sabine Szunerits

1 January 2017 in Journal of Controlled Release
Verified
Journal Article
Closed access
FTFlorina Teodorescu
Florina Teodorescu
GQGurvan Quéniat
Gurvan Quéniat
CFCatherine Foulon
Catherine Foulon
MLMarie Lecoeur
Marie Lecoeur
ABAlexandre Barras
Alexandre Barras
SSSabine Szunerits
Sabine Szunerits

1 January 2017 in Electrochimica Acta
Verified
Journal Article
Closed access
HMHoucem Maaoui
Houcem Maaoui
SSSantosh K. Singh
Santosh K. Singh
FTFlorina Teodorescu
Florina Teodorescu
YCYannick Coffinier
Yannick Coffinier
ABAlexandre Barras
Alexandre Barras
Rabah BoukherroubRabah Boukherroub
Rabah Boukherroub

18 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MHMaaoui Houcem
Maaoui Houcem
FTFlorina Teodorescu
Florina Teodorescu
QWQian Wang
Qian Wang
Guo-Hui PanGuo-Hui Pan
Guo-Hui Pan
AAAhmed Addad
Ahmed Addad
Rabah BoukherroubRabah Boukherroub
Rabah Boukherroub
Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes) leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate detection of glucose in the blood at low cost remains a challenging task, although it is of great importance for the diagnosis and therapy of diabetic patients. In this work, carbon quantum dots decorated with copper oxide nanostructures (CQDs/Cu2O) are prepared by a simple hydrothermal approach, and their potential for electrochemical non-enzymatic glucose sensing is evaluated. The proposed sensor exhibits excellent electrocatalytic activity towards glucose oxidation in alkaline solutions. The glucose sensor is characterized by a wide concentration range from 6 µM to 6 mM, a sensitivity of 2.9 ± 0.2 µA·µM−1·cm−2, and a detection limit of 6 µM at a signal-to-noise ratio S/N = 3. The sensors are successfully applied for glucose determination in human serum samples, demonstrating that the CQDs/Cu2O-based glucose sensor satisfies the requirements of complex sample detection with adapted potential for therapeutic diagnostics.

5 August 2016 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
CJChiara Mauriello Jimenez
Chiara Mauriello Jimenez
Nikola KneževićNikola Knežević
Nikola Knežević
YRYolanda Galàn Rubio
Yolanda Galàn Rubio
SSSabine Szunerits
Sabine Szunerits
Rabah BoukherroubRabah Boukherroub
Rabah Boukherroub
JDJean-Olivier Durand
Jean-Olivier Durand
We report nanodiamond–PMO nanosystems which generate ROS upon two-photon excitation.