David Zadok

Dr. David Zadok

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2020 in Journal of Medical Virology
Verified
Journal Article
Closed access
PDF file
EBEmmanuel Bettach
Emmanuel Bettach
DZDavid Zadok
David Zadok
YWyishay weill
yishay weill
KBKobi Brosh
Kobi Brosh
JHJoel Hanhart
Joel Hanhart

20 May 2021 in Cornea
Verified
Journal Article
Closed access
LWLauren M. Wasser
Lauren M. Wasser
EREduardo Roditi
Eduardo Roditi
DZDavid Zadok
David Zadok
LBLiron Berkowitz
Liron Berkowitz
YWyishay weill
yishay weill
Purpose: The aim of this report was to report 2 patients who presented with acute corneal graft rejection 2 weeks after receiving the BNT162b2 messenger RNA (mRNA) vaccine for severe acute respiratory syndrome coronavirus 2. Methods: Case report. Results: Two men, aged 73 and 56 years, with a history of penetrating keratoplasty due to keratoconus were noted to have acute corneal graft rejection 2 weeks after receiving a first dose of the BNT162b2 mRNA vaccine. Both patients were treated with hourly dexamethasone 0.1% and oral prednisone 60 mg per day with prompt resolution of keratoplasty rejection. Conclusions: The BNT162b2 mRNA vaccine may be have been associated with a low-risk corneal graft rejection that responded well to topical and systemic steroids. Treating physicians should be aware of this potential complication and patients should be advised to report any visual changes after vaccination.

1 November 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YKYoav Kan-Tor
Yoav Kan-Tor
AAAdi Shacham Abulafia
Adi Shacham Abulafia
DZDavid Zadok
David Zadok
TKThomas Kohnen
Thomas Kohnen
GSGiacomo Savini
Giacomo Savini
YBYuval Benjamini
Yuval Benjamini
Purpose: To compare 2 different datasets, using Eyetemis, an online analytical tool designed for assessing the spherical equivalent prediction errors (SEQ-PEs) of intraocular lens (IOL) power calculation formulas after cataract surgery. Setting: Institutional. Design: Retrospective case series. Methods: The study comprised 2 distinct datasets of patients who had undergone successful cataract surgery. Dataset 1 includes standard eyes, whereas Dataset 2 includes eyes with keratoconus. An online tool was used for SEQ-PE analysis across the 2 datasets, adhering to ISO standards for evaluating accuracy based on trueness and precision. The tool incorporates robust t tests for comparing the trimmed mean of the data, adjusting for heteroscedasticity. IOL constants in Dataset 1 were optimized for the comparison of Hoffer Q, Holladay 1, SRK/T, Haigis, and Barrett Universal II (BUII) formulas. In Dataset 2, IOL constants from the IOLCon website were used for the comparison of the BUII and its designated KCN version: Barrett TrueK Keratoconus (TrueK [KCN]). Results: For Dataset 1, the trimmed mean SEQ-PE values of all formulas were not significantly different from zero. BUII had superior precision and accuracy compared with all other formulas, except from Haigis (P ≤ .04). For Dataset 2, BUII's trimmed-mean SEQ-PE was significantly different from zero (0.59 diopters [D], P < .01), unlike the TrueK (KCN) (0.12 D, P = .10). In addition, TrueK (KCN) exhibited enhanced precision and accuracy relative to BUII (P < .01). Conclusions: The online analysis tool provides a streamlined approach for assessing the prediction accuracy of SEQ refraction after cataract surgery, effectively evaluating trueness, precision, and overall accuracy through the use of advanced statistical methods.

28 October 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
MVMagali M.S. Vandevenne
Magali M.S. Vandevenne
VWValentijn S.C. Webers
Valentijn S.C. Webers
MSMaartje H.M. Segers
Maartje H.M. Segers
TBTos TJM Berendschot
Tos TJM Berendschot
DZDavid Zadok
David Zadok
AAAdi Shacham Abulafia
Adi Shacham Abulafia
Purpose: To compare the prediction accuracy of the Barrett True-K for keratoconus with standard formulas (SRK/T, Barrett Universal II, and Kane) and the Kane keratoconus formula. Setting: Shaare Zedek Medical Center, Jerusalem, Israel, and University Eye Clinic, Maastricht, the Netherlands. Design: Multicenter retrospective case series. Methods: Eyes with stable keratoconus undergoing cataract surgery were included. The predicted refractions were calculated for SRK/T, Barrett Universal II, Barrett True-K for keratoconus (predicted and measured), Kane, and Kane adjusted for keratoconus formulas. Primary outcomes were prediction error (PE), absolute error (AE), and percentage of eyes with PE ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Subgroup analyses were performed based on the severity of the keratoconus. Results: 57 eyes were included in the study. The PE was not significantly different from zero for SRK/T, Barrett True-K (predicted and measured), and Kane keratoconus formulas (range 0.09 to 0.22 D, P > .05). The AE of Barrett True-K predicted (median 0.14 D) and Barrett True-K measured (median 0.10 D) were significantly lower from Barrett Universal II (median 0.47 D) and Kane (median 0.50 D), P < .001. Conclusions: The Barrett True-K formulas for keratoconus had higher prediction accuracy as compared with new generation formulas and a similar prediction accuracy as compared with the Kane keratoconus formula.

1 February 2003 in Ophthalmology
Verified
Journal Article
Closed access
YBYaniv Barkana
Yaniv Barkana
OSOri Segal
Ori Segal
DKDavid Krakovski
David Krakovski
IAIssac Avni
Issac Avni
DZDavid Zadok
David Zadok

1 August 2021 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
ARAdi Porat Rein
Adi Porat Rein
AAAdi Abulafia
Adi Abulafia
DZDavid Zadok
David Zadok
JHJoel Hanhart
Joel Hanhart
EGEvgeny Gelman
Evgeny Gelman
YWyishay weill
yishay weill