Neeraj Surathu

Dr. Neeraj Surathu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
SRSilvia Rojas Rueda
Silvia Rojas Rueda
TATariq Alsahafi
Tariq Alsahafi
MHMohammed Hammamy
Mohammed Hammamy
NSNeeraj Surathu
Neeraj Surathu
NSNitish Surathu
Nitish Surathu
TSTaiseer Sulaiman
Taiseer Sulaiman
The aim of this study was to evaluate and compare the surface roughness and gloss—both initially and after simulated toothbrushing—of three 3D-printed crown materials subjected to different surface treatments: varnishing, polishing with diamond-impregnated rubber polishers, and polishing with a bristle brush and paste. Disc-shaped specimens (n = 90) were 3D-printed using three commercially available crown resins (Rodin Sculpture, VarseoSmile TriniQ, and OnX Tough 2) and post-processed per manufacturers’ instructions. Specimens were divided into three surface treatment groups: application of a light-cured varnish, polishing with a two-step diamond-impregnated rubber polisher, or polishing with a bristle brush and abrasive paste. Surface roughness and gloss were measured after treatment and again following 20,000 cycles of simulated toothbrushing. Additional specimens were prepared for Vickers microhardness testing and determination of filler weight percentage (wt%). Statistical comparisons were performed using two-way ANOVA with significance set at p < 0.05. Results: The varnish provided the statistically lowest roughness of all surface treatments for all materials. The bristle brush and abrasive paste polishing protocol produced the greatest gloss for the softest material (VarseoSmile TriniQ) and lowest gloss for the hardest material (Rodin Sculpture), whereas the two-step diamond-impregnated rubber polisher produced an equivalent gloss on all materials. Following toothbrushing, roughness was minimally affected; however, gloss was considerably reduced. Conclusions: All tested polishing and varnishing methods achieved clinically acceptable surface roughness (Ra < 0.2 µm) that persisted after simulated toothbrushing. Notably, the two-step diamond-impregnated rubber polisher produced consistent gloss across all materials, while the bristle brush and abrasive paste polishing protocol performed better on softer materials, and varnish application resulted in equal or superior gloss and roughness retention compared to polishing.

27 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
MHMohammed Hammamy
Mohammed Hammamy
NSNeeraj Surathu
Neeraj Surathu
NSNitish Surathu
Nitish Surathu
NLNathaniel Lawson
Nathaniel Lawson
ADAndrea Dardashtian
Andrea Dardashtian
Additive manufacturing has expanded the fabrication of occlusal splints; however, the influence of printing technology and build orientation on accuracy remains unclear. This study evaluated the effect of printing technology (Liquid Crystal Display [LCD] and Digital Light Processing [DLP]) and build orientation (0°, 45°, and 90°) on the trueness of additively manufactured occlusal splints under standardized conditions. A maxillary occlusal splint was digitally designed from a scanned typodont and used as the reference model. Specimens (n = 10/group) were fabricated using two LCD printers (Ackuretta SOL, Phrozen Mini 8K S) and one DLP printer (SprintRay Pro 95S) with a single photopolymer resin (KeySplint Soft). All samples were printed at 100 µm layer thickness and subjected to standardized post-processing. Trueness was assessed by comparing scanned splints to the reference STL using Geomagic Control X and expressed as root mean square (RMS) values. Data were analyzed using two-way ANOVA and Tukey post hoc tests (α = 0.05). Printing technology and build orientation significantly affected trueness (p < 0.001), with RMS values increasing as build orientation increased, and no significant interaction between factors (p > 0.05). LCD systems demonstrated lower RMS values than the DLP system across all orientations. Within the limitations of this study, both factors influenced trueness; however, all systems produced clinically comparable results, supporting the use of LCD technology as a cost-effective option for occlusal splint fabrication.