Brian M. Quinn

Dr. Brian M. Quinn


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2016 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
BQBrian M. Quinn
Brian M. Quinn
ZDZak Dauer
Zak Dauer
NPNeeta Pandit-Taskar
Neeta Pandit-Taskar
HSHeiko Schoder
Heiko Schoder
LDLawrence T. Dauer
Lawrence T. Dauer
Whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) is the standard of care in oncologic diagnosis and staging, and patient radiation dose must be well understood to balance exam benefits with the risk from radiation exposure. Although reference PET/CT patient doses are available, the potential for widely varying total dose prompts evaluation of clinic-specific patient dose. The aims of this study were to use exam-specific information to characterize the radiation dosimetry of PET/CT exams that used two different CT techniques for adult oncology patients and evaluate the practicality of employing an exam-specific approach to dose estimation. Whole body PET/CT scans from two sets of consecutive adult patients were retrospectively reviewed. One set received a PET scan with a standard registration CT and the other a PET scan with a diagnostic quality CT. PET dose was calculated by modifying the standard reference phantoms in OLINDA/EXM 1.1 with patient-specific organ mass. CT dose was calculated using patient-specific data in ImPACT. International Commission on Radiological Protection publication 103 tissue weighting coefficients were used for effective dose. One hundred eighty three adult scans were evaluated (95 men, 88 women). The mean patient-specific effective dose from a mean injected 18F-FDG activity of 450 ± 32 MBq was 9.0 ± 1.6 mSv. For all standard PET/CT patients, mean effective mAs was 39 ± 11 mAs, mean CT effective dose was 5.0 ± 1.0 mSv and mean total effective dose was 14 ± 1.3 mSv. For all diagnostic PET/CT patients, mean effective mAs was 120 ± 51 mAs, mean CT effective dose was 15.4 ± 5.0 mSv and mean total effective dose was 24.4 ± 4.3 mSv. The five organs receiving the highest organ equivalent doses in all exams were bladder, heart, brain, liver and lungs. Patient-specific parameters optimize the patient dosimetry utilized in the medical justification of whole body PET/CT referrals and optimization of PET and CT acquisition parameters. Incorporating patient-specific data into dose estimates is a worthwhile effort for characterizing patient dose, and the specific dosimetric information assists in the justification of risk and optimization of PET/CT.

26 April 2017 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
YGYiming Gao
Yiming Gao
BQBrian M. Quinn
Brian M. Quinn
UMUsman Mahmood
Usman Mahmood
DLDaniel Long
Daniel Long
YEYusuf Erdi
Yusuf Erdi
LDLawrence T. Dauer
Lawrence T. Dauer
Computed Tomography (CT) contributes up to 50% of the medical exposure to the United States population. Children are considered to be at higher risk of developing radiation-induced tumors due to the young age of exposure and increased tissue radiosensitivity. Organ dose estimation is essential for pediatric and adult patient cancer risk assessment. The objective of this study is to validate the VirtualDose software in comparison to currently available software and methods for pediatric and adult CT organ dose estimation. Five age groups of pediatric patients and adult patients were simulated by three organ dose estimators. Head, chest, abdomen-pelvis, and chest-abdomen-pelvis CT scans were simulated, and doses to organs both inside and outside the scan range were compared. For adults, VirtualDose was compared against ImPACT and CT-Expo. For pediatric patients, VirtualDose was compared to CT-Expo and compared to size-based methods from literature. Pediatric to adult effective dose ratios were also calculated with VirtualDose, and were compared with the ranges of effective dose ratios provided in ImPACT. In-field organs see less than 60% difference in dose between dose estimators. For organs outside scan range or distributed organs, a five times’ difference can occur. VirtualDose agrees with the size-based methods within 20% difference for the organs investigated. Between VirtualDose and ImPACT, the pediatric to adult ratios for effective dose are compared, and less than 21% difference is observed for chest scan while more than 40% difference is observed for head-neck scan and abdomen-pelvis scan. For pediatric patients, 2 cm scan range change can lead to a five times dose difference in partially scanned organs. VirtualDose is validated against CT-Expo and ImPACT with relatively small discrepancies in dose for organs inside scan range, while large discrepancies in dose are observed for organs outside scan range. Patient-specific organ dose estimation is possible using the size-based methods, and VirtualDose agrees with size-based method for the organs investigated. Careful range selection for CT protocols is necessary for organ dose optimization for pediatric and adult patients.

3 November 2021 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
JJJohn D. Boice Jr.
John D. Boice Jr.
BQBrian M. Quinn
Brian M. Quinn
IAIsaf Al-Nabulsi
Isaf Al-Nabulsi
AAArmin Ansari
Armin Ansari
PBPaul K. Blake
Paul K. Blake
LDLawrence T. Dauer
Lawrence T. Dauer
Epidemiologic studies of radiation-exposed populations form the basis for human safety standards. They also help shape public health policy and evidence-based health practices by identifying and qu...

1 January 2018 in Physica Medica
Verified
Journal Article
Open access
YGYiming Gao
Yiming Gao
BQBrian M. Quinn
Brian M. Quinn
NPNeeta Pandit-Taskar
Neeta Pandit-Taskar
GBGerald Behr
Gerald Behr
UMUsman Mahmood
Usman Mahmood
LDLawrence T. Dauer
Lawrence T. Dauer
Estimate organ and effective doses from computed tomography scans of pediatric oncologic patients using patient-specific information. With IRB approval patient-specific scan parameters and patient size obtained from DICOM images and vendor-provided dose monitoring application were obtained for a cross-sectional study of 1250 pediatric patients from 0 through 20 y-olds who underwent head, chest, abdomen-pelvis, or chest-abdomen-pelvis CT scans. Patients were categorized by age. Organ doses and effective doses were estimated using VirtualDose™ CT based on patient-specific information, tube current modulation (TCM), and age-specific realistic phantoms. CTDIvol, DLP, and dose results were compared with those reported in the literature. CTDIvol and DLP varied widely as patient size varied. The 75th percentiles of CTDIvol and DLP were no greater than in the literature with the exception of head scans of 16-20 y-olds and of abdomen-pelvis scans of larger patients. Eye lens dose from a head scan was up to 69 mGy. Mean organ doses agreed with other studies at maximal difference of 38% for chest and 41% for abdomen-pelvis scans. Mean effective dose was generally higher for older patients. The highest effective doses were estimated for the 16-20 y-olds as: head 3.3 mSv, chest 4.1 mSv, abdomen-pelvis 10.0 mSv, chest-abdomen-pelvis 14.0 mSv. Patient-specific organ and effective doses have been estimated for pediatric oncologic patients from <1 through 20 y-olds. The effect of TCM was successfully accounted for in the estimates. Output parameters varied with patient size. CTDIvol and DLP results are useful for future protocol optimization.

15 December 2020 in Radiation Protection Dosimetry
Verified
Journal Article
Open access
PDF file
MBMichael Bellamy
Michael Bellamy
DMD Miodownik
D Miodownik
BQBrian M. Quinn
Brian M. Quinn
LDL Dauer
L Dauer
This paper summarizes the dose to the eye lens of workers of Memorial Sloan Kettering Cancer Center, a high-volume US oncologic and associated diseases facility. The doses presented in this report were collected from personal dosemeter readings using optically stimulated luminescence badges to estimate Hp(3). Doses were collected for 5950 clinical and research workers between January 2012 and December 2017. The median eye lens dose for all monitored workers was 0.23 mSv y−1. Workers performing, or supporting, fluoroscopy procedures received the highest unprotected eye lens dose of all workers with a median eye dose of 10 mSv. The use of leaded glasses by this group reduced the actual doses to the lens. Nurses and technicians involved in positron emission tomography injections received median eye lens dose of 1.2 mSv.

29 January 2020 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
BQBrian M. Quinn
Brian M. Quinn
YGYiming Gao
Yiming Gao
UMUsman Mahmood
Usman Mahmood
NPNeeta Pandit-Taskar
Neeta Pandit-Taskar
GBGerald Behr
Gerald Behr
LDLawrence T. Dauer
Lawrence T. Dauer
Background: Organ absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs. Methods: Organ absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old. Results: The mean (+/− standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2–22.3) mSv. The mean (+/− standard deviation, range) PET effective dose was 8.1 (1.2, 5.7–16.5) mSv. The mean (+/− standard deviation, range) CT effective dose was 6.4 (1.8, 2.9–14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads. Conclusions: Organ and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.