Soft robotics is a branch of robotics that deals with mechatronics and electromechanical systems primarily made of soft materials. This paper presents a summary of a chronicle study of various soft robotic hand exoskeletons, with different electroencephalography (EEG)- and electromyography (EMG)-based instrumentations and controls, for rehabilitation and assistance in activities of daily living. A total of 45 soft robotic hand exoskeletons are reviewed. The study follows two methodological frameworks: a systematic review and a chronological review of the exoskeletons. The first approach summarizes the designs of different soft robotic hand exoskeletons based on their mechanical, electrical and functional attributes, including the degree of freedom, number of fingers, force transmission, actuation mode and control strategy. The second approach discusses the technological trend of soft robotic hand exoskeletons in the past decade. The timeline analysis demonstrates the transformation of the exoskeletons from rigid ferrous materials to soft elastomeric materials. It uncovers recent research, development and integration of their mechanical and electrical components. It also approximates the future of the soft robotic hand exoskeletons and some of their crucial design attributes.
Gait events detection allows clinicians and biomechanics researchers to determine timing of gait events, to estimate duration of stance phase and swing phase and to segment gait data. It also aids biomedical engineers to improve the design of orthoses and FES (functional electrical stimulation) systems. In recent years, researchers have resorted to using gyroscopes to determine heel-strike (HS) and toe-off (TO) events in gait cycles. However, these methods are subjected to significant delays when implemented in real-time gait monitoring devices, orthoses, and FES systems. Therefore, the work presented in this paper proposes a method that addresses these delays, to ensure real-time gait event detection. The proposed algorithm combines the use of heuristics and zero-crossing method to identify HS and TO. Experiments involving: (1) normal walking; (2) walking with knee brace; and (3) walking with ankle brace for overground walking and treadmill walking were designed to verify and validate the identified HS and TO. The performance of the proposed method was compared against the established gait detection algorithms. It was observed that the proposed method produced detection rate that was comparable to earlier reported methods and recorded reduced time delays, at an average of 100 ms.
Ankle rehabilitation robots are developed to enhance ankle strength, flexibility and proprioception after injury and to promote motor learning and ankle plasticity in patients with drop foot. This article reviews the design elements that have been incorporated into the existing robots, for example, backdrivability, safety measures and type of actuation. It also discusses numerous challenges faced by engineers in designing this robot, including robot stability and its dynamic characteristics, universal evaluation criteria to assess end-user comfort, safety and training performance and the scientific basis on the optimal rehabilitation strategies to improve ankle condition. This article can serve as a reference to design robot with better stability and dynamic characteristics and good safety measures against internal and external events. It can also serve as a guideline for the engineers to report their designs and findings.