Javier Salinas-Luna

Dr. Javier Salinas-Luna

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2003 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
LSLuis Salas
Luis Salas
ELEsteban Luna
Esteban Luna
JSJavier Salinas-Luna
Javier Salinas-Luna
VGVı´ctor Garcı´a
Vı´ctor Garcı´a
Manuel ServinManuel Servin
Manuel Servin
We present a method to obtain profilometry of a suitable object by fringe projection. The method is appropriate to the case of large objects as compared to the distance from the illuminating source, that is, a nonconstant equivalent wavelength. We develop an experiment to laterally displace a set of fringes on a sphere and obtain quantitative results. There are several orientation parameters involved in the method, and a minimization algorithm is developed to adjust the values of some of them. A series of numerical experiments are performed on this method to test its accuracy under various circumstances. We show that the method can currently attain precisions of ≈λeq/80(λeq stands for equivalent wavelength) and identify possible sources of error. © 2003 Society of Photo-Optical Instrumentation Engineers.

7 December 2023 in Physica Scripta
Verified
Journal Article
Closed access
JSJavier Salinas-Luna
Javier Salinas-Luna
MJMentado-Morales Juan
Mentado-Morales Juan
In this work, an overview of a reference spectral database for diverse organic molecules often used in a chemistry laboratory is shown. Obtained typical Raman signals have been well-resolved within a range from 0 to 3250 cm−1 by using a Coupled-Optical Fiber Raman Spectrograph, COFRS, performing with a sample holder for liquids connected to optical fiber in its typical configuration and an excitation wavelength of 785 ηm. This optical device works by using some spectral acquisition parameters, as integration time, signal average, boxcar or signal smoothing, detector gain and laser variable output power. These last parameter was varied in each compound due to the different purity presented for each organic molecule, and so a higher Raman signal can be obtained. We have included some of the most typical organic molecules used. Further, the main idea is to show a Raman spectral collection for rapid molecular identification of the diverse functional groups related to organic molecules.

1 January 2004 in Optics Express
Verified
Journal Article
Closed access
PDF file
JSJavier Salinas-Luna
Javier Salinas-Luna
ELE. Luna
E. Luna
LSL. Salas
L. Salas
ICIrene Cruz-Gonzalez
Irene Cruz-Gonzalez
ACA. Cornejo-Rodríguez
A. Cornejo-Rodríguez
We present simulated results on piston detection applying the classical Ronchi test to a segmented surface. We have found that a piston error in a test segment, induces a change in the transversal aberration, that can be analyzed by mutually comparing the fringes frequency in each segment. We propose that the piston term of the segmented surface can be recovered by geometrically relating the change in transversal aberration with the piston term. To test this, we have simulated some ronchigrams for a known piston error, and we have been able to recover this term for a dynamic range comprised among 57nm and 550 µm. For piston errors >550µm a change in the transversal aberration can be appreciated and measured in the ronchigrams although these large pistons are now classical defocusings. Thus we have demonstrated that the Ronchi test can be an alternative method for the piston detection with a large dynamic range.

20 May 2006 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JSJavier Salinas-Luna
Javier Salinas-Luna
RMRoberto Machorro
Roberto Machorro
JCJavier Camacho
Javier Camacho
ELEsteban Luna
Esteban Luna
JNJuan Nunez
Juan Nunez
We present an alternative method for cutting optical glass. It works with a high-pressure fluid, carring abrasive powder. This technique offers some advantages over conventional methods that use diamond abrasive covered wires or disks. We make a critical comparison between those two techniques, characterizing cuts with interferometric, polarimetric, and Ronchi testing. The main feature of the water-jet technique is that it allows surface of any shape, already polished, to be cut safely.

1 January 2009 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
FGFermín Granados-Agustín
Fermín Granados-Agustín
JSJavier Salinas-Luna
Javier Salinas-Luna
ACAlejandro Cornejo-Rodríguez
Alejandro Cornejo-Rodríguez
ELEsteban Luna
Esteban Luna
JSJuan Jaime Sánchez-Escobar
Juan Jaime Sánchez-Escobar
JHJuan Manuel Hernández-Cid
Juan Manuel Hernández-Cid
We present a new method for testing an optical surface. It uses the Ronchi test with variable-frequency rulings and a liquid-crystal display. The rulings can be formed by substructuring the spacing of a Ronchi ruling or combining several classical Ronchi rulings in a single variable-frequency ruling. This change allows us to observe smaller defects on the surface, because it enlarges the spatial-frequency domain of the ruling, and a larger dynamic range of detection of the Ronchi test can be obtained instead of increasing the resolution of the detection of the Ronchi test by iteratively changing classical Ronchi rulings with higher line density. As a result, we have found that it is possible to measure defects on a optical surface that are of size ⩾57nm(λ∕11).

1 January 2010
Verified
Book Chapter
Closed access
PDF file
GSGuillermo Sanchez-Diaz
Guillermo Sanchez-Diaz
IPIvan Piza-Davila
Ivan Piza-Davila
Manuel S. Lazo-CortésManuel S. Lazo-Cortés
Manuel S. Lazo-Cortés
MMMiguel Mora-Gonzalez
Miguel Mora-Gonzalez
JSJavier Salinas-Luna
Javier Salinas-Luna