Aaron Wang

Mr. Aaron Wang

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2025 in Nature
Verified
Journal Article
Closed access
PDF file
CDCéline Drieu
Céline Drieu
ZZZiyi Zhu
Ziyi Zhu
ZWZiyun Wang
Ziyun Wang
KFKylie Fuller
Kylie Fuller
AWAaron Wang
Aaron Wang
KKKishore Kuchibhotla
Kishore Kuchibhotla

25 September 2025 in Drug Science, Policy and Law
Verified
Journal Article
Closed access
AWAaron Wang
Aaron Wang
DGDavid Gordon
David Gordon
AKAbigail Kohler
Abigail Kohler
ASAdina Singer
Adina Singer
ARAlexis M. Roth
Alexis M. Roth
CBCameron Baston
Cameron Baston
The current mechanisms in the United States to research and develop novel reversal agents for substances that can lead to overdose are restricted by regulations placed on the pharmaceutical industry. While there are many forms of harm reduction critical to saving lives that require increased investment and research, it is proven that reversal agents, such as naloxone, help prevent overdose morbidity and mortality. In the setting of an evolving crisis of illicit substance use and related overdose with new, increasingly potent substances appearing in communities nationwide, it is essential to implement a structured approach to rapidly develop and deploy efficacious harm reduction tools to save lives. In this article, we review the history of US scheduled drug regulation which aims to mitigate substance use but also paradoxically hinders research into treatments for drug overdose. We also discuss the regulation of drug reversal agents in the context of changing patterns in illicit substance use as well as barriers to the rapid development of medical devices associated with drug reversal agents that address immense public health needs. The overdose epidemic is a national crisis that requires technological solutions in addition to sociopolitical reform. Even if a reversal agent or medication is approved for an emerging substance, the existing regulatory landscape for drug delivery devices discourages the development, access, and widespread adoption of potentially lifesaving treatments. A systematic approach to monitoring the evolution of illicit drugs and a more streamlined regulatory pathway is urgently needed to facilitate the development and deployment of effective harm reduction tools.

15 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
KKKatie N. Kanter
Katie N. Kanter
AWAaron Wang
Aaron Wang
DGDavid Gordon
David Gordon
ASAdina Singer
Adina Singer
JBJacob S. Brenner
Jacob S. Brenner
CBCameron Baston
Cameron Baston
The shoulder may be an effective central site for continuous oxygen saturation (SpO2) monitoring but studies of shoulder-mounted pulse oximetry technology are limited. We hypothesized that an alternative location would be similar in function and user acceptance to a standard FDA-cleared finger-based pulse oximeter. We conducted a quantitative and descriptive pilot study of two prototype biosensor designs in patients with clinical suspicion of hypoxic episodes at an outpatient sleep center. Participants wore two prototype biosensors—the primary a shoulder-mounted adhesive and the secondary a combination ring–bracelet—in addition to a control FDA-approved finger-based pulse oximeter. We assessed the comfort of the devices based on a survey. We monitored 27 patients during an overnight polysomnography study. Participants rated the shoulder-mounted device more highly than the control device on a Likert scale survey of comfort (4.6 out of 5 versus 3.1 out of 5). Open-ended questionnaires showed that the two major criticisms of the control and ring devices were devices falling off and disruption to sleep, while only one participant commented on the shoulder device specifically. We also investigated SpO2 agreement between the primary shoulder-mounted prototype and the control finger-based pulse oximeter. This study confirms that alternative configurations for SpO2 monitoring offer potential as well-tolerated devices with preliminary findings of acceptable agreement. Problems with traditional pulse oximetry, such as false readings of hypoxia due to device removal or noisy data, were encountered less frequently in shoulder-mounted pulse oximetry than in the commercial finger-based device. Future directions include studies of additional populations that are at risk of respiratory collapse and surveys to elicit specific feedback on the configurations, whether positive or negative.

19 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
KKKatie Kanter
Katie Kanter
AWAaron Wang
Aaron Wang
DGDavid Gordon
David Gordon
ASAdina Singer
Adina Singer
JBJacob S Brenner
Jacob S Brenner
CBCameron Baston
Cameron Baston
The shoulder may be an effective central site for continuous oxygen saturation (SpO2) monitoring but studies of shoulder-mounted pulse oximetry technology are limited. We hypothesized that a shoulder-based biosensor device would be similar in function and user acceptance to a standard FDA-cleared finger-based pulse oximeter. We conducted a quantitative and descriptive pilot study of two prototype biosensor designs in patients with clinical suspicion of hypoxic episodes at an outpatient sleep center. Participants wore two prototype biosensors–the first a shoulder-mounted adhesive and the second a combination ring-bracelet–in addition to a control FDA-approved finger-based pulse oximeter. We assessed SpO2 agreement among the devices as well as the comfort of the devices based on a survey. We monitored 27 patients during an overnight polysomnography study. The prototype shoulder pulse oximeter SpO2 readings agreed with the control values of the commercial finger-based pulse oximeter with a 0.72% mean absolute error. Participants rated the shoulder-mounted device more highly than the control device on a Likert-scale survey of comfort (4.6 out of 5 versus 3.1 out of 5). Open-ended questionnaires showed that the two major criticisms of the control and ring devices were devices falling off and disruption to sleep while only one participant commented on the shoulder device, specifically. This study confirms that alternative configurations for SpO2 monitoring offer potential as accurate and well-tolerated devices. Problems with traditional pulse oximetry, such as false readings of hypoxia due to device removal or noisy data, were encountered less frequently in shoulder-mounted pulse oximetry than in the commercial finger-based device. Future directions include studies of additional populations that are at risk of respiratory collapse and surveys to elicit specific feedback on the configurations, whether positive or negative.