In this study, sodium hydroxide and calcium hydroxide are employed as activators to enhance the properties of foam concrete with hybrid alkali-activated cementitious material as the base mix. The effect of the activators on the properties of foam concrete is studied. The experimental results reveal that the presence of sodium hydroxide can also enhance the hydration rate of the base mix and increase the density of the pore wall in foamed concrete, thus enhancing the compressive strength of foamed concrete. Meanwhile, the addition of excessive sodium hydroxide may introduce too much water and increase the settlement of foamed concrete, thus resulting in a coarse and uneven pore structure. The settlement of the foam concrete with calcium hydroxide as an activator can be significantly increased, which is more related to the settlement of the matrix. The presence of calcium hydroxide could enhance dense pore walls, thus increasing the compressive strength and lowering water absorption.
Closed-type winding GFRP (CW-GFRP) stirrups are obtained by winding continuous fibers fully impregnated with resin on the mould layer by layer. Compared to pultruded stirrups, the CW-GFRP stirrups have a higher bend strength and no overlap sections. For concrete beams with CW-GFRP stirrups subjected to shear, due to the angle between the stirrup and the diagonal crack, the main tensile stresses acting on the stirrup can be resolved into a tensile force along the stirrup and a shear force perpendicular to the stirrup. The strength of the stirrup straight section in this composite state was called the shear-tensile strength. So far, there are few studies about the shear-tensile strength of CW-GFRP stirrups. In this paper, a new shear-tensile test method was proposed and tested for 23 specimens, including twenty CW-GFRP stirrups and three pultruded GFRP stirrups. The main parameters included the cross-sectional dimensions and diagonal crack angle. The test results showed that the bend strength of CW-GFRP stirrups was improved by 81% ∼ 115% and the shear-tensile strength was enhanced by 4% ∼ 19% compared with those of pultruded stirrups. Besides, as the angle of diagonal cracks increased from 35° to 55°, the shear-tensile strength decreased by 10% ∼ 28%, and the decrease was related to the cross-sectional dimensions of CW-GFRP stirrups. The greater the width-to-thickness ratio, the more significant the decrease. Furthermore, the shear-tensile strength overall increased with increasing thickness and decreased with increasing width. When the cross-sectional area was certain, the shear-tensile strength decreased with increasing width-to-thickness ratio and the bend strength exhibited opposite trends. Finally, a shear-tensile strength prediction model for CW-GFRP stirrups was proposed. For the application of CW-GFRP stirrups in beams, width-to-thickness ratios ranging from 1.5 to 2.67 and taking 60% of the tensile strength as the shear-tensile strength are recommended.
18 June 2026 in Construction and Building Materials
Fiber-reinforced polymers (FRPs) are being increasingly applied as reinforcement in new concrete structures, particularly in aggressive environments, owing to their better mechanical and durability properties and ease of installation. However, the brittle failure of FRP bars, combined with the inadequate confinement of conventional pultruded FRP bar ties, caused by fiber kinking at bends and bond-slip at overlaps, limits the structural performance of columns. To overcome these drawbacks, this study explores a novel hybrid-reinforced concrete (HRC) column that employs steel bars as primary reinforcement in combination with in-situ direct-wound rectangular CFRP strip ties, offering superior confinement compared with conventional FRP bar ties. A numerical model was developed using Abaqus and validated against test results, achieving predictions within 10% of measured values. Subsequently, a detailed parametric study was conducted to evaluate the effects of concrete compressive strength, tie spacing, tie cross-sectional area, tie width, and load eccentricity on the axial behavior of HRC columns. The results showed that increasing tie spacing from 70 to 160 mm reduced peak load and confinement efficiency by 8 and 36%, respectively, while increasing the tie cross-sectional area from 15 to 105 mm 2 enhanced the confinement efficiency by about 32%. Moreover, increasing the tie width from 15 to 30 mm had a negligible effect on confined strength, whereas further increasing the width from 30 to 50 mm enhanced the confined strength by up to 5.5%. Higher concrete strength increased the axial load capacity but reduced confinement effectiveness because of the relatively brittle response of high-strength concrete. Finally, building upon these findings, analytical equations were proposed to calculate the confined concrete strength of HRC columns.