Background: To determine the usefulness of dose volume histogram (DVH) factors for predicting the occurrence of radiation pneumonitis (RP) after application of stereotactic radiation therapy (SRT) for lung tumors, DVH factors were measured before irradiation. Methods: From May 2004 to April 2006, 25 patients were treated with SRT at the University of Tokyo Hospital. Eighteen patients had primary lung cancer and seven had metastatic lung cancer. SRT was given in 6–7 fields with an isocenter dose of 48 Gy in four fractions over 5–8 days by linear accelerator. Results: Seven of the 25 patients suffered from RP of symptomatic grade 2–5 according to the NCI-CTC version 3.0. The overall incidence rate of RP grade2 or more was 29% at 18 months after completing SRT and three patients died from RP. RP occurred at significantly increased frequencies in patients with higher conformity index (CI) (p = 0.0394). Mean lung dose (MLD) showed a significant correlation with V5–V20 (irradiated lung volume) (p < 0.001) but showed no correlation with CI. RP did not statistically correlate with MLD. MLD had the strongest correlation with V5. Conclusion: Even in SRT, when large volumes of lung parenchyma are irradiated to such high doses as the minimum dose within planning target volume, the incidence of lung toxicity can become high.
Cone beam computed tomography (CBCT) plays an important role in image-guided radiation therapy (IGRT), while having disadvantages of severe shading artifact caused by the reconstruction using scatter contaminated and truncated projections. The purpose of this study is to develop a deep convolutional neural network (DCNN) method for improving CBCT image quality. CBCT and planning computed tomography (pCT) image pairs from 20 prostate cancer patients were selected. Subsequently, each pCT volume was pre-aligned to the corresponding CBCT volume by image registration, thereby leading to registered pCT data (pCTr). Next, a 39-layer DCNN model was trained to learn a direct mapping from the CBCT to the corresponding pCTr images. The trained model was applied to a new CBCT data set to obtain improved CBCT (i-CBCT) images. The resulting i-CBCT images were compared to pCTr using the spatial non-uniformity (SNU), the peak-signal-to-noise ratio (PSNR) and the structural similarity index measure (SSIM). The image quality of the i-CBCT has shown a substantial improvement on spatial uniformity compared to that of the original CBCT, and a significant improvement on the PSNR and the SSIM compared to that of the original CBCT and the enhanced CBCT by the existing pCT-based correction method. We have developed a DCNN method for improving CBCT image quality. The proposed method may be directly applicable to CBCT images acquired by any commercial CBCT scanner.
Introduction: The abscopal effect is the effect of radiation therapy at a site distant to the area of irradiation. This is not a common event and has not been clearly defined, resulting in few reported cases in the literature. We discuss this phenomenon in a patient with hepatocellular carcinoma. Case presentation: A 63-year-old Japanese man underwent extended right hepatic lobectomy for hepatocellular carcinoma. During his follow-up examination, a single lung metastasis and a single mediastinal lymph node metastasis were found. Trans-catheter arterial embolization was initially attempted to treat the mediastinal tumor, however this approach failed to take effect and carried risks of spinal artery embolism. External-beam irradiation, with a dose of 2.25 Gy per fraction, was performed using an antero-posterior parallel-opposed technique (total dose, 60.75 Gy). A computed tomography scan performed one month after starting radiotherapy showed a remarkable reduction of the mediastinal lymph node metastasis. In addition to this, we observed spontaneous shrinking of the lung metastasis, which was located in the right lower lobe and out of the radiation field. No chemotherapy was given during the period. There has been no recurrence of either the lung metastasis or the mediastinal lymph node metastasis during a follow-up 10 years after the radiotherapy. Conclusion: We observed a rare abscopal effect in a site distant from the area of irradiation. Irradiation of the mediastinum resulted in tumor mass regression in the untreated lung tumor.
To determine the risk factors of severe radiation pneumonitis (RP) after stereotactic body radiation therapy (SBRT) for primary or secondary lung tumors. From January 2003 to March 2009, SBRT was performed on 117 patients (32 patients before 2005 and 85 patients after 2006) with lung tumors (primary = 74 patients and metastatic/recurrent = 43 patients) in our institution. In the current study, the results on cases with severe RP (grades 4-5) were evaluated. Serum Krebs von den Lungen-6 (KL-6) and serum Surfactant protein-D (SP-D) were used to predict the incidence of RP. A shadow of interstitial pneumonitis (IP) on the CT image before performing SBRT was also used as an indicator for RP. Since 2006, patients have been prescreened for biological markers (KL-6 & SP-D) as well as checking for an IP-shadow in CT. Grades 4-5 RP was observed in nine patients (7.7%) after SBRT and seven of these cases (6.0%) were grade 5 in our institution. A correlation was found between the incidence of RP and higher serum KL-6 & SP-D levels. IP-shadow in patient's CT was also found to correlate well with the severe RP. Severe RP was reduced from 18.8% before 2005 to 3.5% after 2006 (p = 0.042). There was no correlation between the dose volume histogram parameters and these severe RP patients. Patients presenting with an IP shadow in the CT and a high value of the serum KL-6 & SP-D before SBRT treatment developed severe radiation pneumonitis at a high rate. The reduction of RP incidence in patients treated after 2006 may have been attributed to prescreening of the patients. Therefore, pre-screening before SBRT for an IP shadow in CT and serum KL-6 & SP-D is recommended in the management and treatment of patients with primary or secondary lung tumors.