Liguo Zhang

Liguo Zhang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
GWGuohua Wu
Guohua Wu
JTJiejuan Tong
Jiejuan Tong
LZLiguo Zhang
Liguo Zhang
YZYunfei Zhao
Yunfei Zhao
ZDZhiyong Duan
Zhiyong Duan

1 April 2020 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
YZYunfei Zhao
Yunfei Zhao
JTJiejuan Tong
Jiejuan Tong
LZLiguo Zhang
Liguo Zhang
GWGuohua Wu
Guohua Wu

1 May 2015 in Progress in Nuclear Energy
Verified
Journal Article
Closed access
YZYunfei Zhao
Yunfei Zhao
LZLiguo Zhang
Liguo Zhang
JTJiejuan Tong
Jiejuan Tong

1 January 2018 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
HDHongchun Ding
Hongchun Ding
JTJiejuan Tong
Jiejuan Tong
YWYongfu Wang
Yongfu Wang
LZLiguo Zhang
Liguo Zhang

1 September 2015 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
YZYunfei Zhao
Yunfei Zhao
JTJiejuan Tong
Jiejuan Tong
LZLiguo Zhang
Liguo Zhang
QZQin Zhang
Qin Zhang

1 January 2017 in Science and Technology of Nuclear Installations
Verified
Journal Article
Open access
PDF file
JCJianzhu Cao
Jianzhu Cao
LZLiguo Zhang
Liguo Zhang
FXFeng Xie
Feng Xie
BXBing Xia
Bing Xia
SLStephen Tsz Tang Lam
Stephen Tsz Tang Lam
The high temperature gas-cooled reactor pebble-bed module (HTR-PM) in China received much attention for its inherent safety performance and high thermal efficiency. The generation mechanism, distribution, reduction route, and release type of tritium (H-3) in HTR-PM are presented with a complete theoretical model. The calculation results indicate the majority of H-3 in the core is generated by the activation reaction of B-10. The activity concentration of H-3 in the primary loop and the specific activity of H-3 in the secondary loop at the operating equilibrium are computed as 3.69 × 106 Bq/m3STPof helium and 4.22 × 104 Bq/kg of water, respectively. The H-3 sampling measurement in HTR-PM has been designed to collect data from the primary coolant, from the liquid waste storage tank, from the secondary coolant, and from the liquid and gaseous effluents, separately. In this paper, the design of H-3 sampling positions in the helium purification system is discussed. The H-3 sampling measurement from the primary helium in HTR-PM has been improved, which can provide reliable activity concentration data of H-3 in the primary loop and supply accurate evaluation for the efficiency of the helium purification system.