Steven Sarkisian

Dr. Steven Sarkisian

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Ophthalmology
Verified
Journal Article
Open access
TSThomas W. Samuelson
Thomas W. Samuelson
SSSteven Sarkisian
Steven Sarkisian
DLDavid M. Lubeck
David M. Lubeck
MSMichael C. Stiles
Michael C. Stiles
YDYi-Jing Duh
Yi-Jing Duh
FCFrank Cotter
Frank Cotter
Evaluate the safety and effectiveness of an ab interno implanted (iStent inject) Trabecular Micro-Bypass System (Glaukos Corporation, San Clemente, CA) in combination with cataract surgery in subjects with mild to moderate primary open-angle glaucoma (POAG). Prospective, randomized, single-masked, concurrently controlled, multicenter clinical trial. Eyes with mild to moderate POAG and preoperative intraocular pressure (IOP) ≤24 mmHg on 1 to 3 medications, unmedicated diurnal IOP (DIOP) 21 to 36 mmHg, and cataract requiring surgery. After uncomplicated cataract surgery, eyes were randomized 3:1 intraoperatively to ab interno implantation of iStent inject (Model G2-M-IS; treatment group, n = 387) or no stent implantation (control group, n = 118). Subjects were followed through 2 years postoperatively. Annual washout of ocular hypotensive medication was performed. Effectiveness end points were ≥20% reduction from baseline in month 24 unmedicated DIOP and change in unmedicated month 24 DIOP from baseline. Safety measures included best spectacle-corrected visual acuity (BSCVA), slit-lamp and fundus examinations, gonioscopy, pachymetry, specular microscopy, visual fields, complications, and adverse events. The groups were well balanced preoperatively, including medicated IOP (17.5 mmHg in both groups) and unmedicated DIOP (24.8±3.3 mmHg vs. 24.5±3.1 mmHg in the treatment and control groups, respectively, P = 0.33). At 24 months, 75.8% of treatment eyes versus 61.9% of control eyes experienced ≥20% reduction from baseline in unmedicated DIOP (P = 0.005), and mean reduction in unmedicated DIOP from baseline was greater in treatment eyes (7.0±4.0 mmHg) than in control eyes (5.4±3.7 mmHg; P < 0.001). Of the responders, 84% of treatment eyes and 67% of control eyes were not receiving ocular hypotensive medication at 23 months. Furthermore, 63.2% of treatment eyes versus 50.0% of control eyes had month 24 medication-free DIOP ≤18 mmHg (difference 13.2%; 95% confidence interval, 2.9-23.4). The overall safety profile of the treatment group was favorable and similar to that in the control group throughout the 2-year follow-up. Clinically and statistically greater reductions in IOP without medication were achieved after iStent inject implantation with cataract surgery versus cataract surgery alone, with excellent safety through 2 years.

7 December 2023 in Drugs
Verified
Journal Article
Open access
PDF file
JBJohn Berdahl
John Berdahl
SSSteven Sarkisian
Steven Sarkisian
RARobert E. Ang
Robert E. Ang
LDLong V. Doan
Long V. Doan
AKAngela C. Kothe
Angela C. Kothe
TNTomas Navratil
Tomas Navratil
Purpose A randomized, double-masked, multicenter, phase 2 trial to evaluate the long-term safety and efficacy of travoprost intraocular implant, an extended-release drug delivery system designed to provide uninterrupted sustained intraocular pressure (IOP)-lowering therapy, thereby reducing patient treatment burden and improving adherence with IOP-lowering medication. Methods Patients with open-angle glaucoma or ocular hypertension were administered a fast-eluting implant (FE implant, n = 51) and received twice-daily (BID) placebo eye drops, a slow-eluting (SE implant, n = 54) and received BID placebo eye drops, or underwent a sham surgical procedure and received BID timolol 0.5% (n = 49). IOP was measured at baseline, day 1–2, day 10, week 4, week 6, month 3, and every 3 months thereafter through 36 months. Efficacy was evaluated by mean change from 8:00 AM unmedicated baseline IOP through month 36, and the percentage of patients receiving the same or fewer topical IOP-lowering medications as at screening (pre-study). Safety was evaluated by adverse events and ophthalmic parameters. Results Clinically and statistically relevant IOP-lowering treatment effects were observed through month 36 after a single administration of the travoprost implant compared with BID timolol with mean IOP reductions ranging from 7.6 to 8.8 mmHg for the FE implant group, from 7.3 to 8.0 mmHg for the SE implant group, and from 7.3 to 7.9 for the timolol group at the 8:00 AM timepoint (P < 0.0001 for all treatment groups at all visits). At months 12, 24, and 36, a greater percentage of FE and SE implant patients versus timolol patients were well controlled on the same or fewer topical IOP-lowering medications compared with screening with 63 and 69% for the FE and SE implants groups, respectively, versus 45% for the timolol group at month 36. The safety profile of the implant was favorable; there were no dislodgements, no explantations, no adverse events of conjunctival hyperemia or periorbital fat atrophy, no discontinuations due to study eye adverse events, nor any serious adverse events in the study eye. Comparable changes from baseline in corneal endothelial cell counts were observed in the three treatment groups over the 36 months. Conclusion The travoprost intraocular implant demonstrated robust IOP-lowering and substantially reduced topical IOP-lowering medication burden for up to 36 months following a single administration, while maintaining a favorable safety profile. The travoprost intraocular implant promises to be a meaningful addition to the interventional glaucoma armamentarium by addressing the key shortcomings of topical IOP-lowering medications, including low adherence and topical side effects while controlling IOP for up to 36 months. Trial Registry ClinicalTrials.gov identifier NCT02754596 registered 28 April 2016.

12 February 2024 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
SSSteven Sarkisian
Steven Sarkisian
RARobert E. Ang
Robert E. Ang
ALAndy M. Lee
Andy M. Lee
JBJohn Berdahl
John Berdahl
SHSebastian B. Heersink
Sebastian B. Heersink
TNTomas Navratil
Tomas Navratil
Introduction This prospective, multicenter, randomized, double-masked pivotal phase 3 trial evaluated the efficacy and safety of the travoprost intracameral SE-implant (slow-eluting implant, the intended commercial product) and FE-implant (fast-eluting implant, included primarily for masking purposes) compared to twice-daily (BID) timolol ophthalmic solution, 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods The trial enrolled adult patients with OAG or OHT with an unmedicated mean diurnal intraocular pressure (IOP) of ≥ 21 and unmedicated IOP ≤ 36 mmHg at each diurnal timepoint (8 a.m., 10 a.m., and 4 p.m.) at baseline. The eligible eye of each patient was administered an SE-implant, an FE-implant or had a sham administration procedure. Patients who received an implant were provided placebo eye drops to be administered BID and patients who had the sham procedure were provided timolol eye drops to be administered BID. The primary efficacy endpoint, for which the study was powered, was mean change from baseline IOP at 8 a.m. and 10 a.m. at day 10, week 6, and month 3. Non-inferiority was achieved if the upper 95% confidence interval (CI) on the difference in IOP change from baseline (implant minus timolol) was < 1.5 mmHg at all six timepoints and < 1 mmHg at three or more timepoints. The key secondary endpoint was mean change from baseline IOP at 8 a.m. and 10 a.m. at month 12. Non-inferiority at month 12 was achieved if the upper 95% CI was < 1.5 mmHg at both timepoints. Safety outcomes included treatment-emergent adverse events (TEAEs) and ophthalmic assessments. Results A total of 590 patients were enrolled at 45 sites and randomized to one of three treatment groups: 197 SE-implant (the intended commercial product), 200 FE-implant, and 193 timolol. The SE-implant was non-inferior to timolol eye drops in IOP lowering over the first 3 months, and was also non-inferior to timolol at months 6, 9, and 12. The FE-implant was non-inferior to timolol over the first 3 months, and also at months 6 and 9. Of those patients who were on glaucoma medication at screening, a significantly greater proportion of patients in the SE- and FE-implant groups (83.5% and 78.7%, respectively) compared to the timolol group (23.9%) were on fewer topical glaucoma medications at month 12 compared to screening (P < 0.0001, chi-square test). TEAEs, mostly mild, were reported in the study eyes of 39.5% of patients in the SE-implant group, 34.0% of patients in the FE-implant group and 20.1% of patients in the timolol group. Conclusions The SE-travoprost intracameral implant demonstrated non-inferiority to timolol over 12 months whereas the FE-implant demonstrated non-inferiority over 9 months. Both implant models were safe and effective in IOP lowering in patients with OAG or OHT. Trial Registration ClinicalTrials.gov identifier, NCT03519386.

6 September 2024 in Drugs
Verified
Journal Article
Open access
PDF file
ISI. Paul Singh
I. Paul Singh
JBJohn Berdahl
John Berdahl
SSSteven Sarkisian
Steven Sarkisian
LVLilit A. Voskanyan
Lilit A. Voskanyan
RARobert E. Ang
Robert E. Ang
TNTomas Navratil
Tomas Navratil
Aim The purpose of this study was to conduct and interpret a pooled 12-month analysis of two prospective, multi-center, randomized, double-masked, controlled trials designed to assess the efficacy and safety of the travoprost intracameral implant (slow-eluting [SE] implant in development as a new therapeutic and fast-eluting [FE] implant included for masking purposes) in subjects with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods Subjects with OAG or OHT, on 0–3 intraocular pressure (IOP)-lowering medications, baseline unmedicated mean diurnal IOP of ≥ 21 mmHg, and IOP ≤ 36 mmHg at each baseline diurnal timepoint, received either a travoprost implant and twice-daily (BID) placebo eye drops or BID timolol 0.5% eye drops and a sham procedure. Subjects were followed through 12 months and assessed for IOP, reduction in topical IOP-lowering medications, and safety parameters including treatment-emergent adverse events (TEAEs). IOP at 8AM was prospectively collected at all study visits through 12 months and diurnal IOP, measured at 8AM, 10AM, and 4PM, was prospectively collected at baseline, day 10, week 6, and months 3 and 12. Results A total of 1150 subjects were randomized (385 FE implant, 380 SE implant, and 385 sham/timolol) across the two trials. Statistical non-inferiority to timolol and clinically relevant reductions in 8AM IOPs were demonstrated at month 12. In more detail, both implant groups demonstrated statistical non-inferiority to timolol and clinically relevant reductions from baseline in mean diurnal IOP at all visits over the 12-month evaluation period when diurnal IOP was collected. Additionally, both implant groups demonstrated robust treatment effect based on 8AM average IOP from day 10 through the specified visit which ranged from day 10 to month 12 from 6.9 to 8.5 mmHg in the FE implant group; 6.8 to 8.5 mmHg in the SE implant group; and 7.3 to 7.5 mmHg in the sham/timolol group. With regards to reduction in topical pharmacotherapy, at month 12, 77.6% of FE and 81.4% of SE implant eyes were completely free of all topical IOP-lowering medications and a significantly greater proportion of FE and SE implant eyes (89.9% and 93.0%) versus sham/timolol eyes (66.9%) were on the same or fewer topical IOP-lowering medications compared with pre-study (p < 0.0001). Furthermore, of subjects on topical IOP medications at screening, a significantly greater proportion of FE implant (80.2%) and SE implant (85.1%) eyes versus sham/timolol (22.8%) eyes were on fewer topical IOP-lowering medications at month 12 compared with pre-study (p < 0.0001). Lastly, of SE implant eyes on same or fewer topical IOP-lowering medications at month 12, the average through month 12 decreased by 0.9 medications, and of those SE implant eyes on fewer topical IOP-lowering medications compared with pre-study, the average through month 12 decreased by 1.4 medications. The most common TEAEs related to study treatment were hyperemia (conjunctival or ocular), iritis, and IOP increased. Conclusion The travoprost intracameral implant demonstrated robust IOP-lowering efficacy that was sustained and statistically non-inferior to timolol over the entire 12 months, resulting in a significant reduction in topical IOP-lowering medication use, with the majority of SE implant eyes remaining completely free of all topical IOP-lowering medications. In addition, the implant demonstrated a favorable safety and tolerability profile based on this pooled 12-month analysis of two pivotal trials. Trial Registration ClinicalTrials.gov identifiers NCT03519386 (registered May 09, 2018) and NCT03868124 (registered March 08, 2019).

1 February 2021 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
MGMark J Gallardo
Mark J Gallardo
SSSteven Sarkisian
Steven Sarkisian
SVSteven D Vold
Steven D Vold
ISInder Paul Singh
Inder Paul Singh
BFBrian E Flowers
Brian E Flowers
TSThomas W Samuelson
Thomas W Samuelson
Purpose: To report interim 6-month safety and efficacy outcomes of 360° canaloplasty and 180° trabeculotomy using the OMNI® Surgical System concomitantly with phacoemulsification in patients with open-angle glaucoma (OAG). Setting: Fifteen multi-subspecialty ophthalmology practices and surgery centers located in 14 states (Alabama, Arizona, Arkansas, Florida, Georgia, Iowa, Kansas, Montana, Nebraska, North Dakota, Oklahoma, Pennsylvania, Texas, and Wisconsin). Design: Prospective, multicenter, IRB approved study of patients treated with canaloplasty (360°) and trabeculotomy (180°). Eligible patients had cataract and mild-moderate OAG with intraocular pressure (IOP) ≤ 33 mmHg on 1 to 4 hypotensive medications. Methods: Medication washout prior to baseline diurnal IOP (Goldmann). Effectiveness outcomes included mean IOP and medications. Safety outcomes included adverse events (AE), best corrected visual acuity (BCVA) and secondary surgical interventions (SSI). Analysis includes descriptive statistics and t-tests evaluating change from baseline. Results: A total of 137 patients were enrolled and treated. Mean diurnal IOP after washout was 23.8 ± 3.1 mmHg at baseline. At month 6, 78% (104/134) were medication free with IOP of 14.2 mmHg, a mean reduction of 9.0 mmHg (38%). 100% (104/104) had a ≥ 20% reduction in IOP and 86% (89/104) had IOP ≥ 6 and ≤ 18 mmHg. The mean number of medications at screening was 1.8 ± 0.9 and 0.6 ± 1.0 at month 6. AE included transient hyphema (4.6%) and IOP elevation ≥ 10 mmHg (2%). There were no AE for loss of BCVA or recurring hyphema. There were no SSI. Conclusion: Canaloplasty followed with trabeculotomy and performed concomitantly with phacoemulsification has favorable intra and perioperative safety, significantly reduces IOP and anti-glaucoma medications through 6 months in eyes with mild-moderate OAG.

9 July 2020 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
SSSteven Sarkisian
Steven Sarkisian
NRNathan Radcliffe
Nathan Radcliffe
PHPaul Harasymowycz
Paul Harasymowycz
SVSteven Vold
Steven Vold
TPThomas Patrianakos
Thomas Patrianakos
FCfor the ASCRS Glaucoma Clinical Committee,
for the ASCRS Glaucoma Clinical Committee,
Minimally invasive glaucoma surgery (MIGS) has become a reliable standard of care for the treatment of glaucoma when combined with cataract surgery. This review describes the MIGS procedures currently combined with and without cataract surgery with a focus on visual outcomes based on the literature and the experience of the ASCRS Glaucoma Clinical Committee.