Iron oxide nanoparticles have been extensively utilised as negative (T2) contrast agents in magnetic resonance imaging. In the past few years, researchers have also exploited their application as positive (T1) contrast agents to overcome the limitation of traditional Gd3+ contrast agents. To provide T1 contrast, these particles must present certain physicochemical properties with control over the size, morphology and surface of the particles. In this review, we summarise the reported T1 iron oxide nanoparticles and critically revise their properties, synthetic protocols and application, not only in MRI but also in multimodal imaging. In addition, we briefly summarise the most important nanoparticulate Gd and Mn agents to evaluate whether T1 iron oxide nanoparticles can reach Gd/Mn contrast capabilities.
Here, we present a comprehensive review on the use of microwave chemistry for the synthesis of iron-oxide nanoparticles focused on molecular imaging. We provide a brief introduction on molecular imaging, the applications of iron oxide in biomedicine, and traditional methods for the synthesis of these nanoparticles. The review then focuses on the different examples published where the use of microwaves is key for the production of nanoparticles. We study how the different parameters modulate nanoparticle properties, particularly for imaging applications. Finally, we explore principal applications in imaging of microwave-produced iron-oxide nanoparticles.
Iron oxide nanomaterial is a typical example of a magnetic resonance imaging probe for negative contrast. It has also been shown how this nanomaterial can be synthesized for positive contrast by modification of the composition and size of the core. However, the role of the organic coating in the relaxometric properties is largely unexplored. Here, maghemite nanoparticles with either excellent positive or very good negative contrast performance are obtained by modifying coating thickness while the core is kept unchanged. Different nanoparticles with tailored features as contrast agent according to the coating layer thickness have been obtained in a single-step microwave-driven synthesis by heating at different temperatures. A comprehensive analysis is conducted of how the composition and structure of the coating affects the final magnetic, relaxometric, and imaging performance. These results show how the organic coating plays a fundamental role in the intrinsic relaxometric parameters of iron oxide-based contrast media.
In vivo detection and quantification of inflammation is a major goal in molecular imaging. Furthermore, cell-specific detection of inflammation would be a tremendous advantage in the characterization of many diseases. Here, we show how this goal can be achieved through the synergistic combination of nanotechnology and nuclear imaging. One of the most remarkable features of this hybrid approach is the possibility to tailor the pharmacokinetics of the nanomaterial-incorporated biomolecule and radionuclide. A good example of this approach is the covalent binding of a large amount of a neutrophil-specific, hydrophobic peptide on the surface of 68Ga core-doped nanoparticles. This new nano-radiotracer has been used for non-invasive in vivo detection of acute inflammation with very high in vivo labelling efficiency, i.e. a large percentage of labelled neutrophils. Furthermore, we demonstrate that the tracer is neutrophil-specific and yields images of neutrophil recruitment of unprecedented quality. Finally, the nano-radiotracer was successfully detected in chronic inflammation in atherosclerosis-prone ApoE−/− mice after several weeks on a high-fat diet.
Synthesizing iron oxide nanoparticles for positive contrast in magnetic resonance imaging is the most promising approach to bring this nanomaterial back to the clinical field. The success of this approach depends on several aspects: the longitudinal relaxivity values, the complexity of the synthetic protocol, and the reproducibility of the synthesis. Here, we show our latest results on this goal. We have studied the effect of Cu doping on the physicochemical, magnetic, and relaxometric properties of iron oxide nanoparticles designed to provide positive contrast in magnetic resonance imaging. We have used a one-step, 10 min synthesis to produce nanoparticles with excellent colloidal stability. We have synthesized three different Cu-doped iron oxide nanoparticles showing modest to very large longitudinal relaxivity values. Finally, we have demonstrated the in vivo use of these kinds of nanoparticles both in angiography and targeted molecular imaging.
1 April 2019 in Nanomedicine: Nanotechnology, Biology and Medicine
The importance of atherosclerosis is driving research to create improved diagnostic tools based on molecular imaging. Pretargeted imaging is the use of bioorthogonal probes that selectively accumulate upon reaction with a pre-modified biomolecule in vivo. To date, this very promising approach has not been applied to atherosclerosis. Neither has been the use of a single nano-radiomaterial for PET / T1-MR imaging of atherosclerosis. Here, we synthesized bioorthogonal nano-radiomaterials for in vivo pretargeted molecular imaging in a mouse model of atherosclerosis. Based on tetrazine-ligation, these functionalized 68Ga iron oxide nano-radiomaterials provide simultaneous PET and T1-MRI signals and selectively accumulate in atherosclerotic plaques in mice sequentially injected with trans-cyclooctene-modified antibodies against oxidized LDL followed by the hybrid nano-radiomaterial. Our results demonstrate the ability of this approach to unambiguously detect atherosclerosis. Furthermore, we show the first example of how hybrid imaging can be used for pretargeted bioorthogonal molecular imaging with nanomaterials.