Huy Dinh

Mr. Huy Dinh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
HDHuy Dinh
Huy Dinh
FVFernando Vinuela
Fernando Vinuela
VSViktor Szeder
Viktor Szeder
KKKasra Khatibi
Kasra Khatibi
LMLucido Ponce Mejia
Lucido Ponce Mejia
ACAichi Chien
Aichi Chien

1 January 2023 in Stroke: Vascular and Interventional Neurology
Verified
Journal Article
Open access
PDF file
HYHong‐Ho Yang
Hong‐Ho Yang
JSJames Sayre
James Sayre
HDHuy Dinh
Huy Dinh
KNKambiz Nael
Kambiz Nael
GCGeoffrey Colby
Geoffrey Colby
ACAichi Chien
Aichi Chien
Background: Although image‐derived predictors of intracranial aneurysm (IA) rupture have been well explored, current understanding of IA growth is limited. Pulsatility index (PI) and wall shear stress PI (WSSPI) are important metrics measuring temporal hemodynamic instability. However, they have not been investigated in IA growth research. The present study seeks to verify reliable predictors of IA growth with comparative analyses of several important morphological and hemodynamic metrics between stable and growing cases among a group of unruptured IAs. Methods: Using 3‐dimensional images, vascular models of 16 stable and 20 growing cases were constructed and verified using geodesic techniques. With an overall mean follow‐up period of 25 months, cases exhibiting a ≥10% increase in diameter were considered growing. Patient‐specific, pulsatile simulations were performed, and hemodynamic calculations were computed at 5 important regions of each aneurysm (inflow artery, aneurysm neck, body, dome, and outflow artery). Index values were compared between growing and stable IAs using ANCOVA controlling for aneurysm diameter. Stepwise multiple logistic regression and receiver operation characteristic analyses were conducted to investigate predictive models of IA growth. Results: Compared with stable IAs, growing IAs exhibited significantly higher intrasaccular PI, intrasaccular WSSPI, intrasaccular spatial flow rate deviation, and intrasaccular spatial wall shear stress deviation. Stepwise logistic regression analysis revealed a significant predictive model involving PI at aneurysm body, WSSPI at inflow artery, and WSSPI at aneurysm body. Conclusions: Our results showed that high degrees of hemodynamic variation within IAs are linked to growth, even after controlling for morphological parameters. Furthermore, evaluation of PI in conjunction with WSSPI yielded a highly accurate predictive model of IA growth. On validation in future cohorts, these metrics may aid in early identification of IA growth and understanding of IA remodeling mechanisms.

26 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HDHuy Dinh
Huy Dinh
JZJoanne Zhou
Joanne Zhou
ABAdam Benmira
Adam Benmira
DKDeborah Kenney
Deborah Kenney
ALAmy L. Ladd
Amy L. Ladd
Motion analysis can be useful for multiplanar analysis of hand kinematics. The carpometacarpal (CMC) joint has been traditionally difficult to capture with surface-based motion analysis but is the most commonly arthritic joint of the hand and is of particular clinical interest. Traditional 3D motion capture of the CMC joint using multiple cameras and reflective markers and manual goniometer measurement has been challenging to integrate into clinical workflow. We therefore propose a markerless single-camera artificial intelligence (AI)-assisted motion capture method to provide real-time estimation of clinically relevant parameters. Our study enrolled five healthy subjects, two male and three female. Fourteen clinical parameters were extracted from thumb interphalangeal (IP), metacarpal phalangeal (MP), and CMC joint motions using manual goniometry and live motion capture with the Google AI MediaPipe Hands landmarker model. Motion capture measurements were assessed for accuracy, precision, and correlation with manual goniometry. Motion capture demonstrated sufficient accuracy in 11 and precision in all 14 parameters, with mean error of −2.13 ± 2.81° (95% confidence interval [CI]: −5.31, 1.05). Strong agreement was observed between both modalities across all subjects, with a combined Pearson correlation coefficient of 0.97 (p < 0.001) and an intraclass correlation coefficient of 0.97 (p < 0.001). The results suggest AI-assisted live motion capture can be an accurate and practical thumb assessment tool, particularly in virtual patient encounters, for enhanced range of motion (ROM) analysis.

23 January 2021 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
JYJingwen Yao
Jingwen Yao
CWChencai Wang
Chencai Wang
CRCatalina Raymond
Catalina Raymond
BBBlake Bergstrom
Blake Bergstrom
XCXing Chen
Xing Chen
BEBenjamin M. Ellingson
Benjamin M. Ellingson

1 March 2021 in Stroke
Verified
Journal Article
Closed access
ACAichi Chien
Aichi Chien
HDHuy Dinh
Huy Dinh
VSViktor Szeder
Viktor Szeder
FVFernando Vinuela
Fernando Vinuela
Introduction: Clinical reports show that cerebral blood flow conditions are indicative of cerebral vascular disease. While methods for characterizing cerebral vascular flow have been extensively reported in the past, comparative analyses between direct flow measurements (DM) and computational flow dynamic (CFD) analysis remain limited. We hypothesize that flow data can be reliably measured both directly and through CFD in normal vessels. Methods: A left heart replicator was used as a realistic cardiac pump which maintained systolic pressure at 120 mmHg and diastolic pressure at 80 mmHg. A stenotic model with 50% stenosis for the ICA was connected to the replicator. A ComboWire was used for DM and recorded flow pressure and velocity. CFD was used to study flow. Results: In areas at the proximal end of the stenosis, the pressure and flow velocity derived from DM and CFD were in good agreement. At the end of systole and diastole, DM pressure were 145.42 mmHg and 73.53 mmHg, respectively. CFD simulation for the same system obtained the pressure at the end of systole and diastole of 147.16 mmHg and 74.64 mmHg, respectively. The velocity data collected from DM was at 15.40 cm/s and 7.74 cm/s for systolic flow and mean flow velocity. CFD measured flow was 17.85 cm/s and 11.37 cm/s, respectively. In areas at the distal end of the stenosis, pressure data showed good agreement between DM and CFD analysis. The DM were 138 and 70.81 mmHg at the end of systole and diastole, respectively; CFD simulation yielded 145.95 and 74.51 mmHg, respectively. Variations in the velocity data were observed at this location (Fig, pink arrows). Conclusion: DM of pressure showed good agreement with CFD simulation in all areas of the vessel. DM of velocity using the flow wire were highly affected by location of the measurement. CFD analysis can provide more consistent flow data for flow information collection along the vasculature. Download figure

1 March 2021 in Stroke
Verified
Journal Article
Closed access
HDHuy Dinh
Huy Dinh
Introduction: We examined the viability of pairing wire-obtained flow pressure data with computational fluid dynamic (CFD) analysis for accurate patient-specific 3D reconstruction of flow through cerebral vessels—an approach that provides comprehensive velocity data and other flow parameters to assist the preventative diagnosis of cerebral stenosis. Methods: Two physical phantom models of a cerebral stenosis—differing in regard to vascular morphology at and around the stenosis—were prepared, filled with physiological saline and connected individually to a flow pump (Vascular Simulations LLC Left Heart Replicator) applying pulsatile flow. Pressure measurements were taken upstream of the stenosis by microcatheter-guided wires to define an inlet boundary condition for CFD analysis. Pressure and velocity at 2 cm proximal to stenosis, the stenosis inlet, the stenosis outlet, and 2 cm distal to stenosis were measured to validate the CFD simulated flow. Results: Excellent agreement was observed between CFD and wire-measured time-dependent flow pressure, with the expected pulsatile behavior observed at each location. Between the two methods, differences in maximum systolic pressures ranged between |0.73±0.72|% and |3.90±0.74|%. Differences in minimum diastolic pressures ranged between |1.79±1.33|% and |9.08±1.42|%. Velocity data from wire measurements lacked pulsatile behavior and showed differences ranging between |2.93±5.20|% and |120.10±2.91|% from CFD-obtained measurements, which did show correct pulsatile behavior. Larger discrepancies were strongly associated with areas of higher CFD predicted velocities (r=0.86). Conclusion: Guidewire flow measurements provided CFD analysis with accurate inlet boundary conditions and validated CFD simulation results. CFD analysis allowed for detailed visualization of key flow parameters that may be difficult to physically measure—such as velocity—that are relevant for understanding risk factors associated with cerebral stenosis on a case-by-case basis.